Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Biomedical Engineering and Bioengineering

A Wearable Mechatronic Device For Hand Tremor Monitoring And Suppression: Development And Evaluation, Yue Zhou Dec 2019

A Wearable Mechatronic Device For Hand Tremor Monitoring And Suppression: Development And Evaluation, Yue Zhou

Electronic Thesis and Dissertation Repository

Tremor, one of the most disabling symptoms of Parkinson's disease (PD), significantly affects the quality of life of the individuals who suffer from it. These people live with difficulties with fine motor tasks, such as eating and writing, and suffer from social embarrassment. Traditional medicines are often ineffective, and surgery is highly invasive and risky. The emergence of wearable technology facilitates an externally worn mechatronic tremor suppression device as a potential alternative approach for tremor management. However, no device has been developed for the suppression of finger tremor that has been validated on a human.

It has been reported in …


Quantifying The Outcomes Of A Virtual Reality (Vr)-Based Gamified Neck Rehabilitation, Shahan Salim Aug 2019

Quantifying The Outcomes Of A Virtual Reality (Vr)-Based Gamified Neck Rehabilitation, Shahan Salim

Electronic Thesis and Dissertation Repository

Neck pain is a major global public health concern and adds a significant financial burden to both the healthcare system as well as people suffering from it. Additionally, it presents measurement and evaluation challenges for clinicians as well as adherence challenges and treatment barriers for the patients. We have developed a virtual reality (VR)-based video game that can be used to capture outcomes that may aid in the assessment and treatment of neck pain. We investigated: (i) performance metrics of overall accuracy, accuracy based on movement difficulty, duration, and total envelope of movement; (ii) stability across sessions; (iii) accuracy across …


System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas Jul 2019

System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas

Mechanical Engineering Theses

One of the important surgical tools in spinal surgery is the C-Arm X-ray System. The C-Arm is a large “C” shaped and manually maneuvered arm that provides surgeons and X-ray technicians the ability to take quick quality X-rays during surgery. Because of its five degrees of freedom, the C-Arm can be manually maneuvered around the patient to provide many angles and perspectives, ensuring surgical success.

This system works fine for most surgical procedures but falls short when the C-Arm must be moved out of the way for complicated surgical procedures.

The aim of this thesis is to develop an accurate …


Using Peripheral Venous Pressure Waveforms To Predict Key Hemodynamic Parameters, Ali Zohair A Alalawi May 2019

Using Peripheral Venous Pressure Waveforms To Predict Key Hemodynamic Parameters, Ali Zohair A Alalawi

Graduate Theses and Dissertations

Analysis of peripheral venous pressure (PVP) waveforms is a novel method of monitoring intravascular volume. Two cohorts were used to study the hemodynamics change of the body state and its influence on the PVP using (1) dehydration setting with infants suffering from pyloric stenosis and (2) hemorrhage setting during a craniosynostosis elective surgery. The goal of this research is to develop a minimally invasive method of analyzing the PVP waveforms and find correlations with volume loss.

Twenty-three pyloric stenosis patients PVP were acquired at five stages and were divided into euvolemic, normal fluid volume, and hypovolemic, significant fluid loss. Seven …


Final Design Report For The Bioburden Pre-Cleaning Device And Dr. Mark Rasnake At The University Of Tennessee Medical Center, Katherine Elizabeth Stiles, Megan Pitz, Kayla Franklin, Simran Dayal, Austin Bullock May 2019

Final Design Report For The Bioburden Pre-Cleaning Device And Dr. Mark Rasnake At The University Of Tennessee Medical Center, Katherine Elizabeth Stiles, Megan Pitz, Kayla Franklin, Simran Dayal, Austin Bullock

Chancellor’s Honors Program Projects

No abstract provided.


Pressure Cylinder Controlled Release Valve, Alexa Dominique Balbuena Mar 2019

Pressure Cylinder Controlled Release Valve, Alexa Dominique Balbuena

Biomedical Engineering

This project aims to integrate an automatic gas release system in a pre-existing scaffold fabrication process for tissue engineering applications.

To form the proper scaffold structure, the fabrication process is heavily influenced by the change in its surrounding pressure. The current production involves a pressure transducer and electric valve that is managed manually to create a suitable pressure environment for the scaffold. This method, although functional, proves to be ineffective when creating several batches; the user needs to constantly monitor the developing pressure profile and alter voltage parameters accordingly to create a linear gas release under a predetermined slope.

To …


A Microfluidic Tissue Array (Μfta) For Personalized Medicine Using Tumor Biopsies, A.H. R. Ahmed Jan 2019

A Microfluidic Tissue Array (Μfta) For Personalized Medicine Using Tumor Biopsies, A.H. R. Ahmed

Dissertations and Theses

Cancer is recognized as a complex disease with both genetic and epigenetic drivers that can vary from one individual to another. While very early research into cancer treated it as a clonal malfunction that could originate from as small as a single deregulated cell, the disease itself manifests itself with several more complexities beyond tumorigenic cells only. The tumor microenvironment itself – from the extracellular matrix to stromal cells - cooperate with tumor cells in a symbiotic manner towards metastatic progression. Clinical studies have provided more information regarding the degree of individualization possible, such that patients with similar genetic makeup …


Design And Testing Of An Agonist-Antagonist Position-Impedance Controlled Myoelectric Prosthesis, Christopher Aymonin Jan 2019

Design And Testing Of An Agonist-Antagonist Position-Impedance Controlled Myoelectric Prosthesis, Christopher Aymonin

Theses and Dissertations

Intuitive prosthetic control is limited by the inability to easily convey intention and perceive physical requirements of the task. Rather than providing haptic feedback and allowing users to consciously control every component of manipulation, relegating some aspects of control to the device may simplify operation. This study focuses on the development and testing of a control scheme able to identify object stiffness and regulate impedance. The system includes an algorithm to detect the apparent stiffness of an object, a proportional nonlinear EMG control algorithm for interpreting a user’s desired grasp aperture, and an antagonistically acting impedance controller. Performance of a …


Neuron-Glial (Ng) Interactions: A Microfluidic Examination Of Ng Emergent Responses For Repair, Tanya Singh Jan 2019

Neuron-Glial (Ng) Interactions: A Microfluidic Examination Of Ng Emergent Responses For Repair, Tanya Singh

Dissertations and Theses

Neuron-glia communication is crucial to the development, plasticity, and repair of the nervous system (NS). While neurons are well known to conduct electrical impulses that transfer biological information and stimuli throughout the NS, our understanding of the roles of glia continues to evolve from when the cells were largely believed to act solely for neuronal support. Recent decades of research has shown that glia can alter metabolism, conduct impulses and change phenotype for NS repair. NG interactions have, thereby, become heavily researched in varied areas of biomedical engineering, including embryogenesis, neural regeneration, growth, and intracellular synaptic activity. However, while NG …


Intensification Of Gas Absorption In A Downward Flow Microbubble Bioreactor, Manizheh Ansari Jan 2019

Intensification Of Gas Absorption In A Downward Flow Microbubble Bioreactor, Manizheh Ansari

Dissertations and Theses

Bioreactors are of interest for value-upgrading of stranded or waste industrial gases, such as CO, CH4, or syngas. Process economics requires reduction of reactor cost and size while maintaining high production rate via rapid delivery of gas feedstock to the liquid phase which in turn requires a high volumetric mass transfer rate (). One strategy to achieve this goal is to increase interfacial area density, a, to >3000 m2 m-3, while minimizing use of energy. Here we show a novel reactor column design that uses a micro-jet array to break feedstock at ambient pressure …


Collective Behavior Of Drosophila Melanogaster Neural Progenitor And Imaginal Disc Cells Within Controlled Microenvironments, Caroline D. Pena Jan 2019

Collective Behavior Of Drosophila Melanogaster Neural Progenitor And Imaginal Disc Cells Within Controlled Microenvironments, Caroline D. Pena

Dissertations and Theses

Regenerative therapies for the damaged visual system have introduced stem-derived cells to recapitulate developmental processes and initiate functional regeneration in different components of the eye. The developing visual system in Drosophila Melanogaster offers a model in which to analyze the associated processes in retinogenesis. The optic nerve is critical to vision and is developmentally preceded in Drosophila by a structure called the Optic Stalk (OS). Collective migration of neural and retinal progenitor cells (RPCs) from the developing brain lobes (DBL) to the Imaginal Disc (ID), through the OS, is a fundamental part of regenerative strategies in retina. Developmental signals governing …