Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

2011

Master's Theses

Discipline
Institution
Keyword

Articles 1 - 30 of 33

Full-Text Articles in Biomedical Engineering and Bioengineering

Impedance-Based Detection Of Tissue Using A Multi-Electrode Device, Shane Killian Fleshman Dec 2011

Impedance-Based Detection Of Tissue Using A Multi-Electrode Device, Shane Killian Fleshman

Master's Theses

Melanoma skin cancer is the abnormal growth of the melanocytes – the pigmented cells located in the epidermis. The current gold standard diagnostic technique for determining whether a lesion is cancerous involves subjectively examining suspicious lesions and performing an invasive biopsy to confirm melanoma. This method may neglect some lesions or cause scarring from biopsies that turn out to be benign. Thus, impedance-based detection using a multi-electrode device was investigated as a noninvasive technique to diagnose melanoma skin cancer. The multi-electrode device was designed with 8 equally spaced Ag/AgCl electrodes surrounding one central electrode at a 5 mm radius. The …


Impact Of Collateral Enlargement On Smooth Muscle Phenotype, Alexander Jerome Bynum Dec 2011

Impact Of Collateral Enlargement On Smooth Muscle Phenotype, Alexander Jerome Bynum

Master's Theses

Peripheral Artery Disease is a very serious disease characterized by an arterial occlusion due to atherosclerotic plaques. In response to an arterial occlusion, arteriogenesis occurs, causing smooth muscle cells to transition from a contractile to synthetic state. Also following an arterial occlusion, functional impairment was seen in the collateral circuit. An immunofluorescence protocol was developed in order to assess the impact of collateral enlargement (arteriogenesis) on smooth muscle phenotype at various time points. Smooth muscle α-actin was used to mark all smooth muscle cells, Ki-67 was used to label proliferating smooth muscle cells, and a fluorescent nuclear stain was used …


Implementation Of Medicinal Leech Preparation To Investigate The Connection Between The Motor Neuron And Muscle Fiber Via Sharp Electrode Electrophysiology, Chandra Nikole Miller Dec 2011

Implementation Of Medicinal Leech Preparation To Investigate The Connection Between The Motor Neuron And Muscle Fiber Via Sharp Electrode Electrophysiology, Chandra Nikole Miller

Master's Theses

There are forty registered organophosphates in the United States and they range from pesticides and insecticides to nerve agents or neurotoxins such as sarin. Organophosphates (OP’s) have been used in chemical warfare for years and tend to lead to death due to an attack on the nervous system. Chemical assays and mass microscopy have been used to assess the concentration of OP’s in the environment, but both methods require the body to metabolize the OP first, which can be detrimental to the victim. It is crucial to come up with a method to investigate and detect these neurotoxins without causing …


Seasonal And Anatomical Variation In Compact Bone Remodeling In The Adult Sheep, Joseph Calcagno Dec 2011

Seasonal And Anatomical Variation In Compact Bone Remodeling In The Adult Sheep, Joseph Calcagno

Master's Theses

ABSTRACT

SEASONAL AND ANATOMICAL VARIATION IN COMPACT BONE REMODELING IN THE ADULT SHEEP

Joseph Calcagno

In order to determine whether ovine compact bone is suitable for study of osteoporosis, the remodeling parameters of the untreated animal must be fully characterized. Ovine compact bone is an attractive large animal model due to its similarities in size and bone remodeling to humans. However hormonal, exercise, and dietary changes due to seasonal changes can cause treatment effects to be hidden or superimposed on existing changes in the bone. In order to determine if any seasonal or anatomical variation occurred in the compact bone …


Protective Effects Of Milk Phospholipids Against Uv Photodamage In Human Skin Equivalents, Zyra Achay Sep 2011

Protective Effects Of Milk Phospholipids Against Uv Photodamage In Human Skin Equivalents, Zyra Achay

Master's Theses

The ultraviolet (UV) spectrum has been known to cause damage to skin in varying degrees. UVB radiation (290-320 nm) in particular, has been proven to be highly mutagenic and carcinogenic in many animal experiments compared to either UVA or UVC. The alarming rate of increase in skin cancer incidence has prompted many investigators to pursue other alternatives to sunscreens including changes in lifestyle habits and dietary consumption in order to boost our efforts in tackling this widespread disease. Previous studies employing confocal reflectance, MTT assay and histology suggest that milk phospholipids may possess protective properties against UVB-mediated damage but the …


Automation Of Orthodontic Wire Tester For Performing Three Point Bending Tests, Adithya Venkatesan Aug 2011

Automation Of Orthodontic Wire Tester For Performing Three Point Bending Tests, Adithya Venkatesan

Master's Theses

Abstract

Understanding the biomechanical factors in orthodontics is important in order to improve the overall effectiveness of actual clinical treatment. An accurate method to study the threedimensional (3D) force systems and the resulting movements of teeth during orthodontic treatment is needed along with the understanding of the material properties of any orthodontic wire. Until recently, most of the orthodontic biomechanics literature was limited to twodimensional experimental studies. Recent advances in threedimensional computer modeling have also been developed but have been limited to the manual control of tooth movement. Overall, there is very little published evidence in the literature on the …


Effect Of Prostaglandin E2 On Mechanical Stresses Applied By Mc3t3-E1 Osteoblast-Like Cells On A Soft Hydrogel Substrate, Abhijit Deb Roy Aug 2011

Effect Of Prostaglandin E2 On Mechanical Stresses Applied By Mc3t3-E1 Osteoblast-Like Cells On A Soft Hydrogel Substrate, Abhijit Deb Roy

Master's Theses

Osteoblasts are sensitive to mechanical stimuli and release Prostaglandin E2 (PGE2) when exposed to a fluid shear stress. The exact mechanism by which these cells sense mechanical stress is not well established. A study of the stresses applied by the osteoblasts, under the influence of PGE2, on a hydrogel provided information regarding intercellular-communication via changes in the substrate surface pattern.

A digital image correlation program was developed using the Levenberg-Marquardt optimization algorithm to analyze images and compare the deformations between pairs of images. Comparisons of images before and after the addition of PE2 to the media showed differences in the …


Glucose Biosensor Using Electrospun Mn2o3-Ag Nanofibers, Shan Huang Aug 2011

Glucose Biosensor Using Electrospun Mn2o3-Ag Nanofibers, Shan Huang

Master's Theses

The highly porous Mn2O3-Ag nanofibers were fabricated by a facile two-step procedure (electrospinning and calcination) and then employed as the immobilization matrix for glucose oxidase (GOD) to construct an amperometric glucose biosensor. A notable enhancement of direct electron transfer between GOD and the electrode is observed at the Mn2O3-Ag-GOD modified electrode with a fast electron transfer rate constant. The biosensor also shows fast response to glucose, high sensitivity (40.60 μA×mM-1×cm-2), low detection limit (1.73 µM at S/N=3), low Km,app value and excellent selectivity. These results indicate that …


Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz Aug 2011

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz

Master's Theses

ICSI (intra-cytoplasmic sperm injection) has attracted research interest from both biological and engineering groups. The technology is constantly evolving to perform this procedure with precision and speed. One such development is the contribution of this thesis. We focus on a relatively recent procedure called Ros-Drill© (rotationally oscillating drill), of which the early versions have already been effectively utilized for the mice. In the first part, we present a procedure to automate a critical part of the operation: initiation of the rotational oscillation, Visual feedback is used to track the pipette tip. Predetermined species-specific penetration depth is successfully utilized …


Equivalent Circuit Implementation Of Demyelinated Human Neuron In Spice, Nathan A. Angel Aug 2011

Equivalent Circuit Implementation Of Demyelinated Human Neuron In Spice, Nathan A. Angel

Master's Theses

This work focuses on modeling a demyelinated Hodgkin and Huxley (HH) neuron with Simulated Program with Integrated Circuit Emphasis (SPICE) platform. Demyelinating disorders affect over 350,000 people in the U.S and understanding the demyelination process at the cellular level is necessary to find safe ways to treat the diseases [9]. Utilizing a previous SPICE model of an electrically small cell neuron developed by Szlavik [32], an extended core conductor myelinated neuron was produced in this work. The myelinated neuron developed has seven active Nodes of Ranvier (nodes) separated by a myelin sheath. The myelin sheath can be successfully modeled with …


Characterizing Nerve Fiber Activation By Varying Fiber Diameter And Depth Within A Conductive Medium: A Finite Element Approach, Nathan Daniel Soto Aug 2011

Characterizing Nerve Fiber Activation By Varying Fiber Diameter And Depth Within A Conductive Medium: A Finite Element Approach, Nathan Daniel Soto

Master's Theses

In some instances neuropathies can be diagnosed through a conduction velocity test. However, not all neuropathies can be classified using this method. Gaining an understanding of how the stimulus level varies for different fiber sizes at different fiber depths within a conductive medium will provide useful information for simulation studies.

Following a two-step approach using COMSOL and MATLAB, a simulation was implemented to investigate the stimulus necessary to activate different sized fibers at different depths. In this two-step approach, COMSOL was used to describe the voltage profile that would be present within a conductive medium after a stimulus was applied. …


Implementation And Assessment Of Hyperglycemic Conditions For The Creation Of A Diabetic Blood Vessel Mimic, Vikramaditya Mediratta Jun 2011

Implementation And Assessment Of Hyperglycemic Conditions For The Creation Of A Diabetic Blood Vessel Mimic, Vikramaditya Mediratta

Master's Theses

Introduction: Diabetes Mellitus is a metabolic disorder that affects a person’s ability to either produce insulin (Type I diabetes mellitus) or properly use insulin (Type II diabetes mellitus) in order to maintain adequate blood glucose levels. The most severe diabetic complications arise due to hyperglycemia – a state of extremely high blood glucose levels – such as, coronary artery disease (CAD), in which coronary stent therapy is a popular method of treatment. However, research has shown a high rate of in-stent restenosis in diabetic patients with CAD, most likely due to activation of cellular adhesion molecules on endothelial cells exposed …


A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell Jun 2011

A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell

Master's Theses

This project encompasses the design and development of a pretreatment microfluidic device for samples of physiological conductivity, namely a saline solution. The conductivity was reduced through the combination of dilution and ion removal using electric fields to enable downstream electro kinetic manipulations. The two major parts of this project include (1) designing a pretreatment protocol to reduce the conductivity of the sample solution to an acceptable level and (2) designing /fabricating a microchip that will effectively allow aim (1) to be performed on chip.

This project is one of the first to observe the effects of an electric field, used …


Ischemia Impairs Vasodilation In Skeletal Muscle Resistance Artery, Kyle Remington Struthers Jun 2011

Ischemia Impairs Vasodilation In Skeletal Muscle Resistance Artery, Kyle Remington Struthers

Master's Theses

Functional vasodilation in arterioles is impaired with chronic ischemia. We sought to examine the impact of chronic ischemia and age on skeletal muscle resistance artery function. To examine the impact of chronic ischemia, the femoral artery was resected from young (2-3mo) and adult (6-7mo) mice and the profunda femoris artery diameter was measured at rest and following gracilis muscle contraction 14 days later using intravital microscopy. Functional vasodilation was significantly impaired in ischemic mice (14.4±4.6% vs. 137.8±14.3%, p<0.0001 n=8) and non-ischemic adult mice (103.0±9.4% vs. 137.8±14.3%, p=0.05 n=10). In order to analyze the cellular mechanisms of the impairment, a protocol was developed to apply pharmacological agents to the experimental preparation while maintaining tissue homeostasis. Endothelial and smooth muscle dependent vasodilation were impaired with ischemia, 39.6 ± 13.6% vs. 80.5 ± 11.4% and 43.0 ± 11.7% vs. 85.1 ± 10.5%, respectively. From this data, it can be supported that smooth muscle dysfunction is the reason for the observed impairment in arterial vasodilation.


Measuring The Nanoindentation Properties Of Alendronate-Time Treated Canine Cortical, Folorunso Ashaolu Jun 2011

Measuring The Nanoindentation Properties Of Alendronate-Time Treated Canine Cortical, Folorunso Ashaolu

Master's Theses

This study examines the nanoindentation (energy inclusive) properties of 0.2 mg/kg alendronate treated ribs at one and three years against a vehicle treated control in a fresh-frozen, non-cold-mounted, condition. This was to verify if the tissue-level properties for 0.2 ALN treated beagles would increase because of an increased level of mineralization despite a microdamage increase.

A total of twelve (12) skeletally mature (1–2 years old) female beagle dogs were treated daily for three years and one year with oral doses of vehicle (VEH, 1 mL/kg saline) or alendronate (ALN, 0.2 Merck, Rahway, NJ). The 0.2 mg dose corresponds, on a …


Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett Jun 2011

Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett

Master's Theses

Development of an Open Source Prosthetic Hand Platform

Scott Garrett

In the field of upper extremity prosthetic devices, advancements in technology drive the design of products which are becoming capable of restoring the lost functions of the native hand. While several dexterous devices have been developed to serve this purpose, they remain prohibitively expensive and thus are not a viable option for many upper extremity amputees. To address this problem a prosthetic hand platform was developed utilizing the open source Arduino microcontroller and off-the-shelf electrical components. Using these resources, a novel finger actuation mechanism was developed to show how …


Studying Milk Coagulation Kinetics With Laser Scanning Confocal Microscopy, Image Processing, And Computational Modeling, Richard Joseph Hennessy Jun 2011

Studying Milk Coagulation Kinetics With Laser Scanning Confocal Microscopy, Image Processing, And Computational Modeling, Richard Joseph Hennessy

Master's Theses

The kinetics of milk coagulation are complex and still not well understood. A deeper understanding of coagulation and the impact of the relevant factors would aid in both cheese manufacturing and also in determining the nutritional benefits of dairy products. A method using confocal microscopy was developed to follow the movement of milk fat globules and the formation of a milk protein network during the enzyme-induced coagulation of milk. Image processing methods were then used to quantify the rate of coagulation. It was found that the texture of the protein network is an indicator of the current status of the …


Seawater/Wastewater Production Of Microalgae-Based Biofuels In Closed Loop Tubular Photobioreactors, Joshua Bradley Lowrey Jun 2011

Seawater/Wastewater Production Of Microalgae-Based Biofuels In Closed Loop Tubular Photobioreactors, Joshua Bradley Lowrey

Master's Theses

The push for alternatives to petroleum fuels has forced researchers to look for highly productive, renewable, non-food resources. The advantages of using microalgae instead of traditional oil crops for biofuel production include high oil yields, rapid reproductive rates, and versatile growing requirements. In order to reduce the cost of producing microalgae based biofuels, wastewater has been used as a nutrient source instead of specialized plant nutrients. The purpose of this study was to compare the relative effectiveness of different combinations of microalgae strain and dairy wastewater for increasing biomass. The methods for monitoring growth included optical density, cell counting, biomass …


A Novel Exercise Device For Users In Wheelchairs: A Study Of Abdominal Muscle Activation, Rebecca Jo Campbell Jun 2011

A Novel Exercise Device For Users In Wheelchairs: A Study Of Abdominal Muscle Activation, Rebecca Jo Campbell

Master's Theses

This study evaluates the use of a wheelchair balance board. The balance board was created as a sensory stimulation tool for users with various disabilities. It was originally designed to create vestibular stimulation for the person after they were loaded on. This study was used as a way to test if the balance board could be used for other things such as physical therapy and exercise. Ten able-bodied individuals were used to show the functionality of the device. They were asked to perform six different abdominal exercises while the muscle activity of their rectus abdominis and external obliques was measured …


Characterization And Implementation Of A Decellularized Porcine Vessel As A Biologic Scaffold For A Blood Vessel Mimic, Aubrey N. Smith Jun 2011

Characterization And Implementation Of A Decellularized Porcine Vessel As A Biologic Scaffold For A Blood Vessel Mimic, Aubrey N. Smith

Master's Theses

Every 34 seconds, someone in the United States suffers from a heart attack. Most heart attacks are caused by atherosclerotic build up in the coronary arteries, occluding normal blood flow. Balloon angioplasty procedures in combination with a metal stent often result in successful restoration of normal blood flow. However, bare metal stents often lead to restenosis and other complications. To compensate for this problem, industry has created drug-eluting stents to promote healing of the artery wall post stenting. These stents are continually advancing toward better drug-eluting designs and methods, resulting in a need for fast and reliable pre-clinical testing modalities. …


Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette May 2011

Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette

Master's Theses

In today’s healthcare environment, networking of medical devices is becoming more and more prevalent. There is an increasing need for mobile technology to meet clinical needs. Wireless communication is essential for allowing medical devices to be able to move with the patient, while continuing to record and communicate patient data. A traditional example is telemetry monitoring, but other examples of wireless utilization include sending ECG test results to the EMR or remotely updating the drug library on numerous IV pumps. Each wireless application has varying demands on the connectivity infrastructure and will share radio frequency (RF) spectrum resources with a …


A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman May 2011

A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman

Master's Theses

Hemoglobin can be measured on a variety of devices using different principles of operation. Noninvasive pulse CO-oximetry represents the latest development in hemoglobin measuring technology. The technology uses principles similar to pulse oximetry to measure total hemoglobin, oxyhemoglobin, reduced oxyhemoglobin, carboxyhemoglobin and methemoglobin. Similar to the introduction of pulse oximetry to the medical field, pulse CO-oximetry has been met with skepticism. Since the technology is noninvasive and provides continuous monitoring in comparison to invasive and discrete techniques used in other methods, CO-oximetry purportedly provides an advantage in patient care. The purpose of this research is threefold: (a) to review the …


Finite Element Analysis Of The Effect Of Low-Speed Rear End Collisions On The Medial Meniscus, Daniel J. Tichon May 2011

Finite Element Analysis Of The Effect Of Low-Speed Rear End Collisions On The Medial Meniscus, Daniel J. Tichon

Master's Theses

Low-speed, rear end vehicle collisions can inflict soft tissue damage to the passenger’s knees, especially the medial meniscus, which has been previously unexplained in published literature. It is difficult to determine if factors such as age or other injury was the primary cause of the injury or if the accident acutely caused the meniscal tear. Rear end collisions may produce a combination of compressive loading and torque about the knee that will injure the medial meniscus during the initial impact and the rebound phase. The purpose of this study is to determine if it is possible for rear end low-speed …


Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri May 2011

Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri

Master's Theses

The development, progression, and treatment of degenerative musculoskeletal diseases, such as carpal tunnel and shoulder impingement syndromes, may be better characterized when joint motions are assessed over long durations outside clinical, laboratory, or rehabilitation settings that involve standardized assessment, exercise protocols, and/or regimented movements. Assessment methods for human movement capture beyond laboratory or clinical experiments are typically limited to short capture times of less than one hour. Noninvasive, long-duration measurements of joint motion in occupational settings provides more insight into movement patterns and quantitative assessments regarding joint usage, which lead to a better understanding of the cumulative effects associated with …


The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito May 2011

The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito

Master's Theses

Adolescent Idiopathic Scoliosis (AIS) is a three dimensional deformity of the spine that causes abnormal curvatures in the coronal and sagittal planes and abnormal vertebral rotations. The gold standard for diagnosing and tracking the progression of the deformity is through the use of repeated radiography and a patient can receive upwards of fifteen radiographic series over the course of treatment, which exposes this population to an increased risk of radiation-dependent complications.

This thesis presents the necessary calculations and the marker set required to make the motion capture technology a viable alternative to radiographs, in an effort to reduce the patient’s …


Characterization And Implementation Of Low Intensity Pulsed Ultrasound As A Tool To Apply Physical Load To Scaffolds And Bone Cells For Fracture Repair, Scott Frazee May 2011

Characterization And Implementation Of Low Intensity Pulsed Ultrasound As A Tool To Apply Physical Load To Scaffolds And Bone Cells For Fracture Repair, Scott Frazee

Master's Theses

One current challenge in treating bone fractures is the effective treatment of non-unions and delayed unions. Low Intensity Pulsed Ultrasound (LIPUS) has been approved by the FDA to treat fresh fractures since 1994 and non-unions since 2000 and is an attractive treatment option because it is non-invasive. The mechanism by which it works, however, is not well understood; what is known is largely confined to the resultant changes in chemical output of cells. In this thesis several concepts and techniques were brought together to investigate the following hypothesis: LIPUS produces a measurable physical load that results in measurable deformation and …


Mammary Epithelial Cell Growth On A Three-Dimensional Scaffold In An Operating Bioreactor, Melissa Marie Davalle May 2011

Mammary Epithelial Cell Growth On A Three-Dimensional Scaffold In An Operating Bioreactor, Melissa Marie Davalle

Master's Theses

Mammary epithelial cells are highly efficient secreting cells. With genetic engineering, the uses of these cells could be endless. Research is being conducted on these cells to determine their full potential to the biotech industry.

This paper investigates whether bovine epithelial mammary cells can survive in glutaraldehyde-treated gelatin tubes in an operating bioreactor. Many bioreactors were developed and tested to suit the needs of the cells. Procedures were created and carried out to ensure sterility of the bioreactors. Bovine mammary epithelial cells were implanted in the bioreactors and samples of their growth were taken over time.


Investigation Of A Simulated Annealing Cooling Schedule Used To Optimize The Estimation Of The Fiber Diameter Distribution In A Peripheral Nerve Trunk, Arya Vigeh May 2011

Investigation Of A Simulated Annealing Cooling Schedule Used To Optimize The Estimation Of The Fiber Diameter Distribution In A Peripheral Nerve Trunk, Arya Vigeh

Master's Theses

In previous studies it was determined that the fiber diameter distribution in a peripheral nerve could be estimated by a simulation technique known as group delay. These results could be further improved using a combinatorial optimization algorithm called simulated annealing. This paper explores the structure and behavior of simulated annealing for the application of optimizing the group delay estimated fiber diameter distribution. Specifically, a set of parameters known as the cooling schedule is investigated to determine its effectiveness in the optimization process.

Simulated annealing is a technique for finding the global minimum (or maximum) of a cost function which may …


Design And Development Of Two Test Fixtures To Test The Longitudinal And Transverse Tensile Properties Of Small Diameter Tubular Polymers, Carolyn Berry Apr 2011

Design And Development Of Two Test Fixtures To Test The Longitudinal And Transverse Tensile Properties Of Small Diameter Tubular Polymers, Carolyn Berry

Master's Theses

Hundreds of thousands of vascular bypass grafts are implanted in the United States every year, but there has yet to be an ideal graft material to substitute for one’s own autologous vessel. Many synthetic materials have been shown to be successful vessel replacements; however, none have been proven to exhibit the same mechanical properties as native vessels, one of the most important criteria in selecting a vascular graft material. Part of this issue is due to the fact that, currently, there is no “gold standard” for testing the longitudinal and transverse tensile properties of small diameter tubular materials. While there …


Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do Mar 2011

Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do

Master's Theses

During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process. In addition, some applications of UEP are incorporated into the official releases of the device product. UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD). This thesis covers the flexible and reusable …