2013

Lung transplantation

Articles 1 - 1 of 1

Full-Text Articles in Biomedical Engineering and Bioengineering

Pulsatile Flow Does Not Improve Efficacy In Ex Vivo Lung Perfusion., Keith A. Zoeller Dec 2013

Pulsatile Flow Does Not Improve Efficacy In Ex Vivo Lung Perfusion., Keith A. Zoeller

Electronic Theses and Dissertations

Introduction Ex vivo lung perfusion (EVLP) has the potential to increase the donor pool for lung transplantation by facilitating extended evaluation of marginal organs. Current methodology employs continuous flow pumps for perfusion. In vivo, continuous flow has been shown to increase pulmonary vascular resistance (PVR). Thus, pulsatile flow EVLP may reduce PVR and improve organ preservation by providing physiologic flow morphology. Methods Lung blocks harvested from male, Yorkshire pigs were allocated into continuous (CF, n=3) and pulsatile flow (PF, n=4) groups. Lungs were ventilated at 4-5 mL/kg, 30% FiO2 and perfused with an acellular, albumin-based solution corrected for osmolarity, acid/base …