Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 30 of 52

Full-Text Articles in Biomedical Engineering and Bioengineering

Tourniquet Pressure Gradient Measurement Apparatus, Luis Enrique Perez, Elsa Elizabeth Bates Mar 2024

Tourniquet Pressure Gradient Measurement Apparatus, Luis Enrique Perez, Elsa Elizabeth Bates

Biomedical Engineering

The goal of this project was to design a device that would measure pressure gradient data across the width of an elastic and inelastic tourniquet cuff using a human limb model. The main customer requirements that were focused on were to accurately measure the pressure from a tourniquet, keep the cost down, and be easy to use. The targeted design specifications were to read pressure values ranging from 0-400 mmHg, keep the test length under 5 minutes, and to keep the cost of materials under $400. The design of the device ended up consisting of 5 IV pouches that were …


Assisted Delivery Device, Rachel Rowe, Madeliene Mumford, Jenna Eissmann, Brittany Trinh Mar 2024

Assisted Delivery Device, Rachel Rowe, Madeliene Mumford, Jenna Eissmann, Brittany Trinh

Biomedical Engineering

Current devices used to assist in complicated births present serious risks to both the mother and the fetus, which has caused a decline in the use of these devices over the last decade. This senior project team has proposed an alternative device that interfaces with the infant’s shoulders that would decrease these risks and contribute to the decrease of unnecessary c-sections due to device inadequacy. This Statement of Work includes research on the downfalls of current devices, existing patents, customer requirements, engineering specifications, and a design plan through December of this year. The next phase of this project will include …


Neonatal Respiratory Therapy Interface, Kennedy Austin, Evan Manley, Parker Murray, Harrison Oen Mar 2024

Neonatal Respiratory Therapy Interface, Kennedy Austin, Evan Manley, Parker Murray, Harrison Oen

Biomedical Engineering

This Final Report reviews and outlines the scope, objectives, and deliverables for the BCPAP Interface Redesign project, aimed at enhancing the functionality, usability, and patient experience of the existing BCPAP interface. It also includes detailed testing results and manufacturing plans for the device prototype. The current system has challenges in universal usability, time constraints, and patient comfort, which this project intends to address effectively. The goal of this project is to reevaluate and redesign the interface of the bubble continuous positive air pressure (BCPAP) machine’s attachment site with the infant. Due to the millions of premature neonates and thousands of …


Postpartum Hemorrhage Detection Device, Kaitlyn Bailey, Adrian Diaz, Alcides Caballero Mar 2023

Postpartum Hemorrhage Detection Device, Kaitlyn Bailey, Adrian Diaz, Alcides Caballero

Biomedical Engineering

During a cesarean section, blood loss greater than 1000 mL is classified as a hemorrhage. Quantified blood loss methods are used to detect hemorrhage, however existing methods are inaccurate and time consuming. Our proposed device is inserted vaginally during a cesarean section to collect and quantify blood lost via the cervix during and after the procedure. The device also applies light suction to the uterus, which can aid in uterus collapse and decrease the risk of postpartum hemorrhage.


Gait Analysis Device For Elderly Fall Prediction, Ryan Hahn, Claudia Miller, Evan Yakligian Mar 2023

Gait Analysis Device For Elderly Fall Prediction, Ryan Hahn, Claudia Miller, Evan Yakligian

Biomedical Engineering

This document serves to outline the design process and final design for our project to address elderly independent living in collaboration with Apple. Included in this document is necessary academic literature of current fall risk assessments and descriptions of the current market of wearable gait analysis devices. Based on this research and data, we then outline a plan for design, manufacturing, prototyping, and testing a device to fulfill the original prompt given by our sponsors: create a device that will increase the ability of an aging loved one to live at home safely. This device is a wearable that collects …


Wire Cutting Saw For Spinal Fusion Surgery, Connor Kilzer Kilzer, Kayla Hong, Kyle Himmelein Jun 2022

Wire Cutting Saw For Spinal Fusion Surgery, Connor Kilzer Kilzer, Kayla Hong, Kyle Himmelein

Biomedical Engineering

The purpose of this project was to design and prototype a spinal facetectomy tool which will minimize the risk of spinal nerve damage and standardize this procedure for all surgeons. This Final Report for Alphatec describes the scope of the project, the process to get to the final prototype of the device, along with a project timeline for the team. A background of current devices and their issues is included to illustrate the need for a new spinal facetectomy device. Within the scope of the project includes a list of customer requirements for the device and the process of translating …


Rod Bend Approximator For Minimally Invasive Spinal Surgery, Amanda Hansell, Anise Ghandchi, Shervin Moghimi Jun 2022

Rod Bend Approximator For Minimally Invasive Spinal Surgery, Amanda Hansell, Anise Ghandchi, Shervin Moghimi

Biomedical Engineering

This Final Report will go over the project deliverables and future steps in the making of a rod bending approximator tool by the Cal Poly Senior Design team for the client SeaSpine. The latest designs and research done regarding minimally invasive surgery (MIS) is covered including the impediments with the current methods. SeaSpine presented the need to our team for an approximating tool within the MIS procedure. Our team began project planning through task generation and schedule development. Once the product definition was fully understood, competition was evaluated and engineering specifications were created for the project. A conceptual design was …


Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda May 2022

Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda

Biomedical Engineering

Falls among the aging population occur every single day, with 1 in every 5 resulting in some injury and 300,000 hospitalized every year with a hip fracture [1]. The most popular and effective way to mitigate these falls is through physical therapist intervention. However, with the increased popularity in telerehab, many patients at risk for falls cannot accurately convey their gait tendencies to their physical therapists from the comfort of their home or while not in direct contact with the PT. A device like an insole, implanted with force sensors, which measures different parts of a patient’s foot, could convey …


Minivette Integrated Sample Prep Funnel For Cepheid Cartridges, Hanna N. Blumer, Sophia Arias, Camille Porciuncula, Ben Runkle Mar 2022

Minivette Integrated Sample Prep Funnel For Cepheid Cartridges, Hanna N. Blumer, Sophia Arias, Camille Porciuncula, Ben Runkle

Biomedical Engineering

This report covers the redesign of the Sample Prep Funnel for Cepheid’s engineering team. The Sample Prep Funnel, responsible for relaying liquid from the sample collection device to the testing cartridge, experiences fluid loss that causes invalid test results. Our group's task was to redesign this funnel to minimize fluid loss and, overall, increase efficiency and effectiveness.


Hand Strength And Dexterity Enhancer, Julia Ann Denison, Autumn B. Rexford, Melissa A. Kurani, Christina K. Fong Jun 2021

Hand Strength And Dexterity Enhancer, Julia Ann Denison, Autumn B. Rexford, Melissa A. Kurani, Christina K. Fong

Biomedical Engineering

Good Grips created the hand strength and dexterity enhancer project to meet the challenge presented by Bill Phelps. He has Inclusion Body Myositis (IBM), an inflammatory muscle disease characterized by progressive muscle weakness and atrophy. Bill has limited strength in both hands and lost the ability to bend his fingers, making it difficult to grip anything. He needed a device that would help with everyday tasks such as writing, lifting, and holding various objects.

Our team consists of four engineering students attending Cal Poly, San Luis Obispo. We researched, designed, manufactured, and tested a device that would fulfill the problem …


Electro-Muscle-To-Muscle Transfer, Hailey Quinn Casino, Jake Keola Javier, Samuel Joseph Borda, Charlotte Amalie Anderson Mar 2021

Electro-Muscle-To-Muscle Transfer, Hailey Quinn Casino, Jake Keola Javier, Samuel Joseph Borda, Charlotte Amalie Anderson

Biomedical Engineering

The Electro Muscle to Muscle Transfer (EMMT) system will entail designing, manufacturing, and providing a wearable device that stimulates paralyzed muscles in the hand by sampling and amplifying muscles from the forearm. With further development, the system may be capable of using different muscle inputs other than the forearm muscles along with different stimulated muscle outputs other than the hand. The system functions as a rehabilitative device for spinal cord injuries, irreparable nerve loss and/or damage, and improper neuromuscular function. It is not for total treatment nor for curing of the disabilities listed above but to alleviate the side effects …


Hypoxic Incubation Chamber, Makenzie Jones, Andrea Skattenborg, Henry Elsner Mar 2021

Hypoxic Incubation Chamber, Makenzie Jones, Andrea Skattenborg, Henry Elsner

Biomedical Engineering

In developing a model to test anti-tumor drugs, Dr. Christopher Heylman’s lab requires the ability to culture cells in a hypoxic environment. The purpose of this project was to make this possible. Funding for this project comes from the Biomedical Engineering Department, the Hannah-Forbes Fund, and Dr. Heylman’s lab. The chamber must be able to reach a user-defined oxygen concentration and hold that concentration for 48 hours while creating an environment conducive to cell culture. Importantly, the chamber must also be sterilizable and cleanable for repeated use. While several products exist to create hypoxic environments for cell culture, they are …


The Tierni Resistance Training System, Michael J. Hansen, Abigail M. Youngblood, Gabriel M. Johnson Mar 2021

The Tierni Resistance Training System, Michael J. Hansen, Abigail M. Youngblood, Gabriel M. Johnson

Biomedical Engineering

The purpose of the Tierni Resistance Training System project was to design and construct functional workout apparel that has built-in resistance. For this product, the key customer requirements we set out to address were most importantly material comfort and functionality, followed by stylishness, lack of latex, safety for injured and uninjured users, and washer safety. To meet these customer requirements, we started by researching current resistance training technology, and used the findings as a springboard for our own design development. After initial brainstorming, engineering specifications were generated based on the customer requirements. These specifications revolved around the thermal insulation, pressure, …


Concussion Detection Device, Jenna C. Sussex, Mark B. Edin, Bianca X. Aleman Jun 2020

Concussion Detection Device, Jenna C. Sussex, Mark B. Edin, Bianca X. Aleman

Biomedical Engineering

No abstract provided.


Alternative Epinephrine Auto-Injector, Joshua Wong, Uriel Nieves-Cruz, Tara Howard Jun 2020

Alternative Epinephrine Auto-Injector, Joshua Wong, Uriel Nieves-Cruz, Tara Howard

Biomedical Engineering

Project: Alternative Epinephrine Injector started as a solution for Bianca Aleman’s little brother however the scope has evolved to include the many millions of individuals across the world who struggle with a life-threatening allergen. The stakeholders of this project are Cal Poly and Dr. Michael D. Whitt. Our goals are the following:

● Develop a foolproof method of injection that consistently delivers a dosage of epinephrine

● Be equal or less than the current size of an EpiPen (6 in)

● Be easy to transport or store when not-in-use

● Create an isolated environment where the epinephrine will not be …


Septal Closure Device, Olivia N. Welch, Hillal H. Jarrar, Kai Harrison Jun 2020

Septal Closure Device, Olivia N. Welch, Hillal H. Jarrar, Kai Harrison

Biomedical Engineering

The septal closure device was designed to seal defects in the atrial septum. To fully seal an atrial defect, the device was designed to consist of two circular seals to cover the defect in both the right and left atria, attached with a central rod. The materials were chosen for compressibility (for ease of insertion), biocompatibility, and tissue ingrowth. A CAD model was drafted in SolidWorks. Key customer requirements include ease of implantation (specifications: adjustable sizing and clear directions for use), physician controlled (specifications: short implantation time and compatibility with current catheter/scope techniques), and a long lifetime (specifications: materials that …


Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster Jun 2020

Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster

Biomedical Engineering

The scope of this project includes designing a non-invasive bubble detector for peripheral venous and arterial lines. For minimally invasive cardiac procedures, arterial and venous access is necessary for these procedures as is constant flow through the tubing to prevent clotting and to administer drugs. Air bubbles are common in these lines and can be consequential if enough air is introduced into the human system. Air embolisms are the most common and relevant issues during these procedures. The goal of this device is to create an attachable detector for air bubbles in saline that can also terminate flow and alert …


Virtual Stethoscope - Otoscope, Ermen J. Elenes-Cazares, Ceasar A. Hurtado, Thomas M. Margolle Jun 2020

Virtual Stethoscope - Otoscope, Ermen J. Elenes-Cazares, Ceasar A. Hurtado, Thomas M. Margolle

Biomedical Engineering

The purpose of this report was to develop a working prototype for a virtual stethoscope and otoscope. Sponsored by Courtney Farr, the virtual diagnostic care system – HouseCalls Mobile digital stethoscope/otoscope is meant for use by medical professionals and non – medical professionals for preliminary medical exams while physically not in a medical setting. The HouseCalls Mobile device is to characterize key biometric parameters such as breathing patterns, heart irregularities, and visual clinical evaluation of the inner ear. This device is intended for pediatric use.


Tmtt Chimera Valve Attachment Process, Paulina Nguyen, Devin Debouk, Tamar Kazazian, Noah Thompson Jun 2020

Tmtt Chimera Valve Attachment Process, Paulina Nguyen, Devin Debouk, Tamar Kazazian, Noah Thompson

Biomedical Engineering

No abstract provided.


D.I.Y. Clean Hood, Samuel G. Porter, Ryan E. Shimogaki, Ryan S. Staples Jun 2020

D.I.Y. Clean Hood, Samuel G. Porter, Ryan E. Shimogaki, Ryan S. Staples

Biomedical Engineering

The DIY Clean Hood is a low-cost, sterile, and accessible scientific workspace intended for installation in the BioElectroFluidics Lab of California Polytechnic State University’s (San Luis Obispo) Biomedical Engineering Department (BMED), under the sponsorship of Dr. Benjamin Hawkins, PhD. As normal Clean Hood, Biosafety Cabinets, and the like are generally too expensive for a university, a competitive solution to an expensive problem can assist research students and professors alike continue their own work with an inexpensive yet effective environment.

Specific design elements that the customer requirements entailed for the project include a low-particle-count air filtration system, positive pressure air flow …


Opendrop Elisa: Surface Development For Digital Microfluidic Elisa Testing, Michaela Q. Mead, Madeline G. Jackson, Jacob G. Taylor May 2020

Opendrop Elisa: Surface Development For Digital Microfluidic Elisa Testing, Michaela Q. Mead, Madeline G. Jackson, Jacob G. Taylor

Biomedical Engineering

This project aimed to develop a process to create a hydrophobic coating with capture antibodies attached. This process was developed in an attempt to create a digital microfluidic platform upon which an enzyme-linked immunosorbent assay (ELISA) could be run, indicated for clinicians and educators in low-resource settings. Four requirements dictated the course of the design process: 1) the contact angle with water of the hydrophobic layer must be greater than 90º, 2) the colorimetric response of a positive ELISA result on our platform must be at least 85% of that run on polystyrene with the same result, 3) the platform …


On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss Mar 2020

On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss

Biomedical Engineering

No abstract provided.


Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen Mar 2020

Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen

Biomedical Engineering

This document comprises the steps taken by the senior project team to create a Proof-of-Concept Review for a Variable Pulsed Electric Field Ablation Catheter. First, the team did a significant amount of background research on related literature to better understand the current status of the project topic. After sufficient background information was obtained, project objectives and deliverables were finalized. Once customer requirements and the indications for use were completed, engineering specifications for the product and project were documented. All key customer requirements and engineering specs were related to the variable pulse functionality, maneuverability, as well as overall dimensioning of the …


Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso Mar 2020

Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso

Biomedical Engineering

The purpose of this scope of work is to highlight the progress and development of SoloStand sponsored by Derek Herrera, chief technical officer and founder of SpinalSingularity. SoloStand is an attachment to a wheelchair that will benefit paraplegics that use wheelchairs. A portable and customizable attachment to a wheelchair will allow the user to do everyday tasks without transferring into a separate standing wheelchair and travel more easily. This document outlines everything that has been done in fulfillment of our senior project requirements.


Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney Mar 2020

Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney

Biomedical Engineering

This project report provides detailed information on designing and building a DIY Incubator. The device is indicated for growing and maintaining BSL-1 mammalian or bacterial cell culture with a temperature control in the range of 25-45°C ± 1°C. The device is made fully programmable via an Arduino, and is structurally designed to fit two T75 cell culture flasks at a time. The device is able to return to a specified temperature set point within 10 minutes and maintains 5% CO2 partial pressure conditions. The incubator has a small physical footprint, with an overall dimension of 22in x 16in x 15.5in …


Prosthetic Thumb, Allison M. Sigdestad, Sahil Sharma, Cale Foreman Mar 2020

Prosthetic Thumb, Allison M. Sigdestad, Sahil Sharma, Cale Foreman

Biomedical Engineering

The Prosthetic Thumb Project is a senior design project completed by Biomedical Engineering Undergraduate students at California Polytechnic State University. This senior design project is aimed at designing a prosthetic thumb for a Cal Poly Pomona student who lost their thumb in an accident last year. The patient has ultimately lost between 30-40% of functionality of his left hand, and so we would like to give him that mobility back. Originally, the patient was worried about having a prosthesis, and wanted something more stagnant that would resemble the look of the thumb he lost. However, after working with him, we …


Esophageal Temperature Mapping And Monitoring Sheath, Nicole M. Rogers, Hillary Johnson, Alexander Silva Mar 2020

Esophageal Temperature Mapping And Monitoring Sheath, Nicole M. Rogers, Hillary Johnson, Alexander Silva

Biomedical Engineering

The purpose of this document is to provide a product development summary for an accessory device that joins an esophageal temperature probe and a mapping catheter together to be used during cardiac ablation. Catheter ablation therapy is performed in the left atrium, utilizing extremely hot or cold temperatures to create scar tissue and treat atrial fibrillation and other arrhythmias. The close positioning of the left atria adjacent to the esophagus presents a large risk as the extreme temperatures used during ablation can lead to esophageal damage or fistulas. This device is designed to integrate correlate data from the temperature probe …


Integrity Testing Of Gas Permeable Silicone Filters, Maggie M. Baker, Thomas P. Humann, Kevin J. Yerina Mar 2020

Integrity Testing Of Gas Permeable Silicone Filters, Maggie M. Baker, Thomas P. Humann, Kevin J. Yerina

Biomedical Engineering

This report investigates the most reasonable, cost efficient, and reliable ways to integrity test a filter made from a permeable silicone membrane for future biomedical and pharmaceutical applications. The goal of the project was to create a fixture that a pharmaceutical company can use to quickly and reliably test the integrity of the filter. A variety of methods are outlined to test the integrity of the filter, after a series of quantitative tests, a single method was established that meet the requirements most thoroughly. The method that was determined to be most effective involves a series of components including a …


Cej Ankle Support Report, Christine Prothe, James Baldwin, Erik Espinoza Jun 2019

Cej Ankle Support Report, Christine Prothe, James Baldwin, Erik Espinoza

Biomedical Engineering

This document provides information about an ankle support device designed to allow for ankle dorsiflexion and plantar flexion. In this document the product’s specifications, objectives and expectations are outlined. Included in this document is background information, stage gate process, prototype design development and considerations, and qualification requirements.


House Calls Mobile Virtual Stethoscope, Abigail Lindquist, Abigael Donohue, Trey Nahhas Jun 2019

House Calls Mobile Virtual Stethoscope, Abigail Lindquist, Abigael Donohue, Trey Nahhas

Biomedical Engineering

The purpose of this scope of work is to outline the progress of the Virtual Stethoscope design and development project as sponsored by House Calls Mobile. This device looks to provide accessible at-home care for patients all over the country through the mobile phone stethoscope attachment. With the virtual stethoscope technology, patients will be able to perform high-quality, in-home observation of heart, stomach, and lung sounds to be transmitted to a physician in real time. Eliminating the need to travel to a doctor’s office encourages patients to perform more regular checkups, increasing their likelihood potentially of life-saving early diagnoses. This …