Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Virginia Commonwealth University

Biomechanics and Biotransport

Magnetic resonance imaging

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Improving The Early Detection Of Cardiovascular Toxicity Secondary To Radiotherapy For Lung Cancer Via Patient-Specific Quantitative Magnetic Resonance Imaging, Alireza Omidi Jan 2022

Improving The Early Detection Of Cardiovascular Toxicity Secondary To Radiotherapy For Lung Cancer Via Patient-Specific Quantitative Magnetic Resonance Imaging, Alireza Omidi

Theses and Dissertations

Purpose: To assess the cardiopulmonary-induced dose variation on the left ventricle (LV) and evaluate the spatiotemporal evolution of cardiac/aortic function following radiotherapy (RT).

Methods: 8 lung cancer patients who were scheduled to receive RT were recruited for this study. Each patient underwent one 4D-CT at baseline. MRI scans including cine GRE, T1/T2, LGE, and 4D-flow were acquired at baseline, 3-months and 6-months post-RT to evaluate the cardiac/aortic function. Finally, image registration was used to assess the cardiopulmonary-induced dose variation on the LV.

Results: Mean RT-dose was minimum during inspiration and systole (at expiration). No significant differences were found in the …


Modeling Of Patient-Specific Periaortic Mechanics And Pulmonary Artery Hemodynamics Based On Phase-Contrast Magnetic Resonance Imaging Sequences., Johane H. Bracamonte Jan 2022

Modeling Of Patient-Specific Periaortic Mechanics And Pulmonary Artery Hemodynamics Based On Phase-Contrast Magnetic Resonance Imaging Sequences., Johane H. Bracamonte

Theses and Dissertations

Inverse modeling in cardiovascular medicine is a collection of methodologies that can provide non-invasive patient-specific estimations of clinical risk factors using medical imaging as inputs. Its incorporation into clinical practice has the potential to improve diagnosis and treatment planning with low associated risks and costs.

Herein, three different phase contrast magnetic resonance imaging (MRI) modalities were implemented as input data, displacement encoding with stimulated echoes (DENSE MRI) applied, and time-resolved velocity encoding phase-contrast MRI, in 1D and 3D, applied to pulmonary artery (PA) hemodynamics.

A model to account for the effect of periaortic interactions due to static and dynamic structures …


Improving Patient-Specific Assessments Of Regional Aortic Mechanics Via Quantitative Magnetic Resonance Imaging With Early Applications In Patients At Elevated Risk For Thoracic Aortopathy, Patrick A. Jones Jan 2021

Improving Patient-Specific Assessments Of Regional Aortic Mechanics Via Quantitative Magnetic Resonance Imaging With Early Applications In Patients At Elevated Risk For Thoracic Aortopathy, Patrick A. Jones

Theses and Dissertations

Unstable aortic aneurysms and dissections are serious cardiovascular conditions associated with high mortality. The current gold standards for assessment of stability, however, rely on simple geometric measurements, like cross-sectional area or increased diameter between follow-up scans, and fail to incorporate information about underlying aortic mechanics. Displacement encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI) has been used previously to determine heterogeneous circumferential strain patterns in the aortas of healthy volunteers. Here, I introduce technical improvements to DENSE aortic analysis and early pilot application in patients at higher risk for the development of aortopathies. Modifications to the DENSE aortic postprocessing …