Articles 1 - 5 of 5

Full-Text Articles in Biomedical Engineering and Bioengineering

Redesign Of The Medtronic Kyphon Bone Cement Mixer For Vertebral Compression Fractures, Mollie Benson, Sarah Freesemann, Aj Konnath, Benjamin Murray Jun 2017

Redesign Of The Medtronic Kyphon Bone Cement Mixer For Vertebral Compression Fractures, Mollie Benson, Sarah Freesemann, Aj Konnath, Benjamin Murray

Biomedical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell Jun 2011

A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell

Master's Theses

This project encompasses the design and development of a pretreatment microfluidic device for samples of physiological conductivity, namely a saline solution. The conductivity was reduced through the combination of dilution and ion removal using electric fields to enable downstream electro kinetic manipulations. The two major parts of this project include (1) designing a pretreatment protocol to reduce the conductivity of the sample solution to an acceptable level and (2) designing /fabricating a microchip that will effectively allow aim (1) to be performed on chip.

This project is one of the first to observe the effects of an electric field, used …


Investigation Of Pmma Cement Penetration In Prepared Femoral Heads With A Longitudinal Slot For Hip Resurfacing Arthroplasty, Scott Snyder Feb 2011

Investigation Of Pmma Cement Penetration In Prepared Femoral Heads With A Longitudinal Slot For Hip Resurfacing Arthroplasty, Scott Snyder

Biomedical Engineering

Hip resurfacing arthroplasty is becoming increasingly popular in younger, active patients due to its preservation of natural biomechanics. Failure of these implants can be very traumatic and potentially life threatening. The role of cement penetration in early implant failure is not yet known, and must be investigated. This study specifically investigates the effects of a 5mm by 5mm longitudinal channel on cement penetration into the femoral head. High-density open-cell reticulated vitreous carbon foam cylinders and Huntsman Pro-cast® 20 implants based on the Birmingham Hip Resurfacing implant were used. It was determined cement penetration was increased in the area immediately surrounding …


Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre Feb 2011

Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre

Master's Theses

This thesis encompasses a feasibility study of using low-cost materials to manufacture microfluidic chips that can perform the same functions as chips manufactured using traditional methods within an acceptable range of efficiency of chips created with more exotic methods and materials. The major parts of the project are the selection and characterization of the fabrication methods for creating the channels for fluid flow, the methods for sealing the channels to create a usable chip and the electrophoretic separations of carboxylated microspheres of different potentials. In this work we seek to answer the question if laser-etched PMMA microfluidic chips are comparable …


Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick May 2010

Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick

Master's Theses

Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.

Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …