Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Deep Learning (2)
- Autoencoders (1)
- Automatic Labeling (1)
- C-Arm (1)
- Convex Optimization (1)
-
- DRR (1)
- Data Reduction (1)
- Edge Computing (1)
- Finite Element Analysis (1)
- Graph-Cuts (1)
- Human Activity Recognition (1)
- Image Fusion (1)
- Image Guided Neurosurgery (1)
- Image Processing (1)
- Imaging Modality (1)
- Integral Images (1)
- IoT (1)
- Machine Learning (1)
- Medical Imaging (1)
- Medical Robotics (1)
- Modal Analysis (1)
- Multi-Modal Medical Image Registration (1)
- Port Placement (1)
- Preoperative Planning (1)
- Probability Product Kernel Classifiers (1)
- Robot Localization (1)
- Simulator (1)
- Spine Diagnosis (1)
- Training (1)
- Ultrasound (1)
Articles 1 - 6 of 6
Full-Text Articles in Biomedical Engineering and Bioengineering
The Role Of Transient Vibration Of The Skull On Concussion, Rodrigo Dalvit Carvalho Da Silva
The Role Of Transient Vibration Of The Skull On Concussion, Rodrigo Dalvit Carvalho Da Silva
Electronic Thesis and Dissertation Repository
Concussion is a traumatic brain injury usually caused by a direct or indirect blow to the head that affects brain function. The maximum mechanical impedance of the brain tissue occurs at 450±50 Hz and may be affected by the skull resonant frequencies. After an impact to the head, vibration resonance of the skull damages the underlying cortex. The skull deforms and vibrates, like a bell for 3 to 5 milliseconds, bruising the cortex. Furthermore, the deceleration forces the frontal and temporal cortex against the skull, eliminating a layer of cerebrospinal fluid. When the skull vibrates, the force spreads directly to …
Simulation Approaches To X-Ray C-Arm-Based Interventions, Daniel R. Allen
Simulation Approaches To X-Ray C-Arm-Based Interventions, Daniel R. Allen
Electronic Thesis and Dissertation Repository
Mobile C-Arm systems have enabled interventional spine procedures, such as facet joint injections, to be performed minimally-invasively under X-ray or fluoroscopy guidance. The downside to these procedures is the radiation exposure the patient and medical staff are subject to, which can vary greatly depending on the procedure as well as the skill and experience of the team. Standard training methods for these procedures involve the use of a physical C-Arm with real X-rays training on either cadavers or via an apprenticeship-based program. Many guidance systems have been proposed in the literature which aim to reduce the amount of radiation exposure …
Edge-Cloud Iot Data Analytics: Intelligence At The Edge With Deep Learning, Ananda Mohon M. Ghosh
Edge-Cloud Iot Data Analytics: Intelligence At The Edge With Deep Learning, Ananda Mohon M. Ghosh
Electronic Thesis and Dissertation Repository
Rapid growth in numbers of connected devices, including sensors, mobile, wearable, and other Internet of Things (IoT) devices, is creating an explosion of data that are moving across the network. To carry out machine learning (ML), IoT data are typically transferred to the cloud or another centralized system for storage and processing; however, this causes latencies and increases network traffic. Edge computing has the potential to remedy those issues by moving computation closer to the network edge and data sources. On the other hand, edge computing is limited in terms of computational power and thus is not well suited for …
Neurosurgical Ultrasound Pose Estimation Using Image-Based Registration And Sensor Fusion - A Feasibility Study, Utsav Pardasani
Neurosurgical Ultrasound Pose Estimation Using Image-Based Registration And Sensor Fusion - A Feasibility Study, Utsav Pardasani
Electronic Thesis and Dissertation Repository
Modern neurosurgical procedures often rely on computer-assisted real-time guidance using multiple medical imaging modalities. State-of-the-art commercial products enable the fusion of pre-operative with intra-operative images (e.g., magnetic resonance [MR] with ultrasound [US] images), as well as the on-screen visualization of procedures in progress. In so doing, US images can be employed as a template to which pre-operative images can be registered, to correct for anatomical changes, to provide live-image feedback, and consequently to improve confidence when making resection margin decisions near eloquent regions during tumour surgery.
In spite of the potential for tracked ultrasound to improve many neurosurgical procedures, it …
Image Fusion And Axial Labeling Of The Spine, Brandon Miles
Image Fusion And Axial Labeling Of The Spine, Brandon Miles
Electronic Thesis and Dissertation Repository
In order to improve radiological diagnosis of back pain and spine disease, two new algorithms have been developed to aid the 75% of Canadians who will suffer from back pain in a given year. With the associated medical imaging required for many of these patients, there is a potential for improvement in both patient care and healthcare economics by increasing the accuracy and efficiency of spine diagnosis. A real-time spine image fusion system and an automatic vertebra/disc labeling system have been developed to address this. Both magnetic resonance (MR) images and computed tomography (CT) images are often acquired for patients. …
Preoperative Planning Of Robotics-Assisted Minimally Invasive Cardiac Surgery Under Uncertainty, Hamidreza Azimian
Preoperative Planning Of Robotics-Assisted Minimally Invasive Cardiac Surgery Under Uncertainty, Hamidreza Azimian
Electronic Thesis and Dissertation Repository
In this thesis, a computational framework for patient-specific preoperative planning of Robotics-Assisted Minimally Invasive Cardiac Surgery (RAMICS) is developed. It is expected that preoperative planning of RAMICS will improve the rate of success by considering robot kinematics, patient-specific thoracic anatomy, and procedure-specific intraoperative conditions. Given the significant anatomical features localized in the preoperative computed tomography images of a patient's thorax, port locations and robot orientations (with respect to the patient's body coordinate frame) are determined to optimize characteristics such as dexterity, reachability, tool approach angles and maneuverability. In this thesis, two approaches for preoperative planning of RAMICS are proposed that …