Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 23 of 23

Full-Text Articles in Biomedical Engineering and Bioengineering

A Wearable Fiber-Free Optical Sensor For Continuous Measurements Of Cerebral Blood Flow And Oxygenation, Xuhui Liu Jan 2023

A Wearable Fiber-Free Optical Sensor For Continuous Measurements Of Cerebral Blood Flow And Oxygenation, Xuhui Liu

Theses and Dissertations--Biomedical Engineering

Wearable technologies for continuous monitoring of cerebral hemodynamics in freely behaving subjects not only advance our understanding of cognitive processing and adaptive behavior, but also provide vital information for diagnosis and therapeutic assessment of cerebral diseases associated with hypoxia/ischemia. Wearable near-infrared diffuse optical techniques have been used at the bedside to probe deep cerebral hemodynamics, including near-infrared spectroscopy (NIRS) for cerebral oxygenation measurement and diffuse correlation spectroscopy (DCS) for cerebral blood flow (CBF) measurement, respectively. However, most systems are relatively large and expensive, and use rigid fiber-optic probes that significantly constrain subject’s movement. A novel, wearable, fiber-free diffuse speckle contrast …


An Electrochemical, Fluidic, Chip-Based Biosensor For Biomarker Detection, Lauren Bell Jan 2022

An Electrochemical, Fluidic, Chip-Based Biosensor For Biomarker Detection, Lauren Bell

Theses and Dissertations--Biomedical Engineering

Biosensors and their use in both the research and clinical field for the detection and monitoring of critical biomarkers are prevalent and constantly improving. However, continued research needs to be done to address shortcomings, such as low sensitivity, poor specificity, and poor readiness for integration into research use and patient care. The objective of this research was to create a combined fluidic, chip-based biosensor that could detect different biomarkers with high sensitivity and ease of use. For assessing the developed sensor, three separate biomarkers were tested: glucose, cholesterol, and oxygen. Both the glucose biosensor and cholesterol biosensor were combined with …


Numerical And Scaling Study On Application Of Inkjet Technology To Automotive Coating, Masoud Arabghahestani Dr. Jan 2022

Numerical And Scaling Study On Application Of Inkjet Technology To Automotive Coating, Masoud Arabghahestani Dr.

Theses and Dissertations--Mechanical Engineering

A thorough literature review identified lack of precision control over quality of droplets generated by the currently available industrial sprayers and a growing need for higher quality droplets in the coating industry. Particularly, lack of knowledge and understanding in continuous inkjets (CIJ) and drop-on-demand (DOD) technologies is identified as significant. Motivated by these needs, this dissertation is dedicated to computational fluid dynamics (CFD) and scaling studies to improve existing inkjet technologies and develop new designs of efficient coating with single and/or multiple piezoelectric sensors to produce on-demand droplets. This dissertation study aims at developing a new DOD type coating technology, …


Additive Manufacturing In Personalized Medicine: Patient-Customized Solid Dose Medicines, And Patient-Customized Wound Care Device, Amir Najarzadeh Jan 2021

Additive Manufacturing In Personalized Medicine: Patient-Customized Solid Dose Medicines, And Patient-Customized Wound Care Device, Amir Najarzadeh

Theses and Dissertations--Mechanical Engineering

Personalized Medicine - from a one-size fits all to a tailored approach is the future in pharmaceutical therapeutics and medical applications. The aim of this study is demonstrate additive manufacturing in two personalized medicine applications: 1. Patient- customized solid dose medicines, and 2. Patient-customized wound care device. The aim of the first application is to develop an inexpensive and accurate method to design and fabricate patient-customized tablets. Particularly this paper focuses on fabricating and dose controlling of patient-customized extended release prednisolone-poly(vinyle alcohole) PVA. Dry-Blending, Wet Granulation, Extrusion, Spherionization, Hot melt extrusion (HME) was adopted to produce drug loaded prednisolone-PVA filaments …


Novel Tools For Analysis Of Disordered Sleep And Motor Behavior In Preclinical Models Of Disease, Dillon M. Huffman Jan 2021

Novel Tools For Analysis Of Disordered Sleep And Motor Behavior In Preclinical Models Of Disease, Dillon M. Huffman

Theses and Dissertations--Biomedical Engineering

Subtle changes in sleep architecture can accompany and be symptomatic of various diseases or disorders. Understanding the complex interactions between sleep and health requires the ability to characterize sleep, probe its underlying mechanisms through perturbation, and quantify dependent physiological outcomes. Rodent models have come to be accepted as a valuable tool for preclinical investigations. However, experimental tools to accomplish such research typically rely on laborious methods that limit throughput and flexibility. Thus, research tools that minimize workload could be of great value to the research community and expedite investigation of the underlying mechanisms of sleep and further the development of …


Assessment Of White Matter Hyperintensity, Cerebral Blood Flow, And Cerebral Oxygenation In Older Subjects Stratified By Cerebrovascular Risk, Ahmed A. Bahrani Jan 2020

Assessment Of White Matter Hyperintensity, Cerebral Blood Flow, And Cerebral Oxygenation In Older Subjects Stratified By Cerebrovascular Risk, Ahmed A. Bahrani

Theses and Dissertations--Biomedical Engineering

Objective: Cerebrovascular disease (CVD) is the fifth most common cause of mortality in the United States. Diagnosis of CVD at an early stage is critical for optimal intervention designed to prevent ongoing and future brain injury. CVD is commonly associated with abnormalities of the cerebral microvasculature leading to tissue dysfunction, neuronal injury and death, and resultant clinical symptoms, which in turn, further impacts cerebral autoregulation (CA). This series of studies aims to test the hypothesis that white matter hyperintensities (WMH) and cerebral hemodynamics (quantified by magnetic resonance imaging (MRI) and an by innovative hybrid near-infrared diffuse optical instrument) can be …


Noncontact Multiscale Diffuse Optical Imaging Of Deep Tissue Hemodynamics In Animals And Humans, Siavash Mazdeyasna Jan 2020

Noncontact Multiscale Diffuse Optical Imaging Of Deep Tissue Hemodynamics In Animals And Humans, Siavash Mazdeyasna

Theses and Dissertations--Biomedical Engineering

Blood flow (BF) impacts the delivery of oxygen and nutrients to tissues and the removal of metabolic byproducts from tissues. Imaging of BF distributions helps characterize many diseases associated with tissue hypoxia/ischemia. The purpose of this study was to develop and validate a novel, noninvasive, noncontact, high-density camera-based speckle contrast diffuse correlation tomography (scDCT) device for use in both animal and human studies. The scDCT uses a galvo-mirror to remotely deliver the focused point near-infrared light to source positions and a sensitive 2D camera to quantify spatial diffuse speckle fluctuations, resulting from the movement of red blood cells in deep …


Knee Joint Loading Following Anterior Cruciate Ligament Reconstruction: Link To Patient Reported Outcomes And A Novel Method To Monitor With Wearable Sensors, Alex Spencer Jan 2020

Knee Joint Loading Following Anterior Cruciate Ligament Reconstruction: Link To Patient Reported Outcomes And A Novel Method To Monitor With Wearable Sensors, Alex Spencer

Theses and Dissertations--Kinesiology and Health Promotion

Recovery from anterior cruciate ligament reconstruction (ACLR) commonly results in undesirable physical and patient-reported outcomes (PROs). Identification of modifiable factors such as knee contact force (KCF) early in rehabilitation that can improve these outcomes is important due to the rapid decrease in function, quality of life, and joint health in this population. Additionally, if noninvasive measurement of KCFs outside of a traditional laboratory were possible, clinicians could optimize patient treatment with personalized care. Therefore, there are two primary aims to this thesis: 1) quantify the link between KCF and PROs which measure pain, ability to perform activities of daily living, …


A Brain-Computer Interface For Closed-Loop Sensory Stimulation During Motor Training In Patients With Tetraplegia, Sarah Helen Thomas Jan 2019

A Brain-Computer Interface For Closed-Loop Sensory Stimulation During Motor Training In Patients With Tetraplegia, Sarah Helen Thomas

Theses and Dissertations--Biomedical Engineering

Normal movement execution requires proper coupling of motor and sensory activation. An increasing body of literature supports the idea that incorporation of sensory stimulation into motor rehabilitation practices increases its effectiveness. Paired associative stimulation (PAS) studies, in which afferent and efferent pathways are activated in tandem, have brought attention to the importance of well-timed stimulation rather than non-associative (i.e., open-loop) activation. In patients with tetraplegia resulting from spinal cord injury (SCI), varying degrees of upper limb function may remain and could be harnessed for rehabilitation. Incorporating associative sensory stimulation coupled with self-paced motor training would be a means for supplementing …


Multimodal Noncontact Diffuse Optical Reflectance Imaging Of Blood Flow And Fluorescence Contrasts, Daniel Irwin Jan 2018

Multimodal Noncontact Diffuse Optical Reflectance Imaging Of Blood Flow And Fluorescence Contrasts, Daniel Irwin

Theses and Dissertations--Biomedical Engineering

In this study we design a succession of three increasingly adept diffuse optical devices towards the simultaneous 3D imaging of blood flow and fluorescence contrasts in relatively deep tissues. These metrics together can provide future insights into the relationship between blood flow distributions and fluorescent or fluorescently tagged agents. A noncontact diffuse correlation tomography (ncDCT) device was firstly developed to recover flow by mechanically scanning a lens-based apparatus across the sample. The novel flow reconstruction technique and measuring boundary curvature were advanced in tandem. The establishment of CCD camera detection with a high sampling density and flow recovery by speckle …


Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson Jan 2018

Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson

Theses and Dissertations--Mechanical Engineering

This thesis proposes an algorithm that determine the geometry of 3D-printed, custom-designed spring element bands made of thermoplastic elastomer (TPE) for use in a wearable orthotic device to aid in the physical therapy of a human hand exhibiting spasticity after stroke. Each finger of the hand is modeled as a mechanical system consisting of a triple-rod pendulum with nonlinear stiffness at each joint and forces applied at the attachment point of each flexor muscle. The system is assumed quasi-static, which leads to a torque balance between the flexor tendons in the hand, joint stiffness and the design force applied to …


Analysis Of Vocal Fold Kinematics Using High Speed Video, Harikrishnan Unnikrishnan Jan 2016

Analysis Of Vocal Fold Kinematics Using High Speed Video, Harikrishnan Unnikrishnan

Theses and Dissertations--Electrical and Computer Engineering

Vocal folds are the twin in-folding of the mucous membrane stretched horizontally across the larynx. They vibrate modulating the constant air flow initiated from the lungs. The pulsating pressure wave blowing through the glottis is thus the source for voiced speech production. Study of vocal fold dynamics during voicing are critical for the treatment of voice pathologies. Since the vocal folds move at 100 - 350 cycles per second, their visual inspection is currently done by strobosocopy which merges information from multiple cycles to present an apparent motion. High Speed Digital Laryngeal Imaging(HSDLI) with a temporal resolution of up to …


Reference Point Indentation Of Human Trabecular Bone Treated With Bisphosphonates For Varying Durations, Drew Jones Jan 2016

Reference Point Indentation Of Human Trabecular Bone Treated With Bisphosphonates For Varying Durations, Drew Jones

Theses and Dissertations--Biomedical Engineering

Reference point indentation (RPI), a novel form of micro-indentation, quantifies RPI material parameters which correlate with modulus, yield stress, strength, or toughness. Information linking bisphosphonate treatment length with the material properties of osteoporotic trabecular bone is needed to improve patient treatment. The objectives of this study were to: 1) determine if RPI can be used to successfully evaluate human trabecular bone and if so, determine an optimized test method for using RPI on trabecular bone, and 2) use this method to determine if any RPI parameters are related to the duration of bisphosphonate treatment.

Indentation using a 4 N applied …


Closed-Loop Afferent Nerve Electrical Stimulation For Rehabilitation Of Hand Function In Subjects With Incomplete Spinal Cord Injury, Christopher J. Schildt Jan 2016

Closed-Loop Afferent Nerve Electrical Stimulation For Rehabilitation Of Hand Function In Subjects With Incomplete Spinal Cord Injury, Christopher J. Schildt

Theses and Dissertations--Biomedical Engineering

Peripheral nerve stimulation (PNS) is commonly used to promote use-dependent cortical plasticity for rehabilitation of motor function in spinal cord injury. Pairing transcranial magnetic stimulation (TMS) with PNS has been shown to increase motor evoked potentials most when the two stimuli are timed to arrive in the cortex simultaneously. This suggests that a mechanism of timing-dependent plasticity (TDP) may be a more effective method of promoting motor rehabilitation. The following thesis is the result of applying a brain-computer interface to apply PNS in closed-loop simultaneously to movement intention onset as measured by EEG of the sensorimotor cortex to test whether …


Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong Jan 2015

Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong

Theses and Dissertations--Biomedical Engineering

Chemo-radiation therapy is a principal modality for the treatment of head and neck cancers, and its efficacy depends on the interaction of tumor oxygen with free radicals. In this study, we adopted a novel hybrid diffuse optical instrument combining a commercial frequency-domain tissue oximeter (Imagent) and a custom-made diffuse correlation spectroscopy (DCS) flowmeter, which allowed for simultaneous measurements of tumor blood flow and blood oxygenation. Using this hybrid instrument we continually measured tumor hemodynamic responses to chemo-radiation therapy over the treatment period of 7 weeks. We also explored monitoring dynamic tumor hemodynamic changes during radiation delivery. Blood flow data analysis …


Collagen Crosslinking Reagent Utilized To Modify The Mechanical Properties Of The Soft Palate In Equine Snoring And Apnea Applications, Stephanie L. Hunt Jan 2015

Collagen Crosslinking Reagent Utilized To Modify The Mechanical Properties Of The Soft Palate In Equine Snoring And Apnea Applications, Stephanie L. Hunt

Theses and Dissertations--Biomedical Engineering

Snoring is a sleep disruption that can lead to obstructive sleep apnea (OSA), which interrupts breathing by obstructing the airway. Injecting a protein crosslinker, such as genipin, into the soft palate could decrease the severity of snoring and OSA by stiffening the soft palate. Equine soft palates modeled human palates due to a high incidence of awake snoring and apnea.

The pilot in vivo study treated six horses with two 100 mM injections of the buffered genipin reagent. The efficacy phase horses underwent respiratory audio recordings to document snoring changes using Matlab and ImageJ in the time and frequency domains. …


Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He Jan 2015

Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He

Theses and Dissertations--Biomedical Engineering

Since aggressive cancers are frequently hypermetabolic with angiogenic vessels, quantification of blood flow (BF) can be vital for cancer diagnosis. Our laboratory has developed a noncontact diffuse correlation tomography (ncDCT) system for 3-D imaging of BF distribution in deep tissues (up to centimeters). The ncDCT system employs two sets of optical lenses to project source and detector fibers respectively onto the tissue surface, and applies finite element framework to model light transportation in complex tissue geometries. This thesis reports our first step to adapt the ncDCT system for 3-D imaging of BF contrasts in human breast tumors. A commercial 3-D …


Human Cardiovascular Responses To Artificial Gravity Variables: Ground-Based Experimentation For Spaceflight Implementation, Mark Howarth Jan 2014

Human Cardiovascular Responses To Artificial Gravity Variables: Ground-Based Experimentation For Spaceflight Implementation, Mark Howarth

Theses and Dissertations--Biomedical Engineering

One countermeasure to cardiovascular spaceflight deconditioning being tested is the application of intermittent artificial gravity provided by centripetal acceleration of a human via centrifuge. However, artificial gravity protocols have not been optimized for the cardiovascular system, or any other physiological system for that matter. Before artificial gravity protocols can be optimized for the cardiovascular system, cardiovascular responses to the variables of artificial gravity need to be quantified.

The research presented in this document is intended to determine how the artificial gravity variables, radius (gravity gradient) and lower limb exercise, affect cardiovascular responses during centrifugation. Net fluid (blood) shifts between body …


Microsphere Spray System For Wound Coverage, Nicholas J. Andersen Jan 2014

Microsphere Spray System For Wound Coverage, Nicholas J. Andersen

Theses and Dissertations--Biomedical Engineering

Spinal fusion is used to treat diseases or disorders of the spine by fusing together two or more vertebrae. Two associated risks with spinal fusion are infection and blood loss. Administration of tranexamic acid is used to prevent blood loss, and transfusions are given following blood loss. Surgical site infections are prevented with vancomycin powder spread into the surgical wound, while established infections are treated by debridement and delivery of antibiotics for 4 to 6 weeks. The present research explored an alternate method to prevent and treat blood loss or infection in spinal fusion. Poly(lactic-co-glycolic acid) (PLGA) microspheres was used …


The Study Of Trunk Mechanical And Neuromuscular Behaviors, Brian D. Koch Jan 2014

The Study Of Trunk Mechanical And Neuromuscular Behaviors, Brian D. Koch

Theses and Dissertations--Biomedical Engineering

Low back pain (LBP) is a common ailment in the United States, affecting up to 80% of adults at least once in their lifetime. Although 90% of LBP cases are considered nonspecific, recent studies show that abnormal mechanics of the lower back can be a major factor. One method of assessing the lower back mechanical environment is through perturbation experiments. An intensive literature review of perturbation systems was used to select and develop a system for the Human Musculoskeletal Biomechanics Lab (HMBL). Following construction, individuals with high/low exposure to day-long physical activity were assessed to quantify daily changes in their …


Diagnosis Of Systemic Inflammation Using Transendothelial Electrical Resistance And Low-Temperature Co-Fired Ceramic Materials, William L. Mercke Jan 2013

Diagnosis Of Systemic Inflammation Using Transendothelial Electrical Resistance And Low-Temperature Co-Fired Ceramic Materials, William L. Mercke

Theses and Dissertations--Chemical and Materials Engineering

Systemic inflammation involves a complex array of cytokines that can result in organ dysfunction. Mortality remains high despite the vast amount of research conducted to find an effective biomarker. The cause of systemic inflammation can be broad and non-specific; therefore, this research investigates using transendothelial electrical resistance (TEER) measurements to better define systemic inflammatory response syndrome (SIRS)/sepsis within a patient. Results show a difference in TEER measurements between healthy individuals and SIRS-rated patients. This research also displays correlations between TEER measurements and biomarkers currently studied with systemic inflammation (tumor necrosis factor-α, C- reactive protein, procalcitonin). Furthermore, this research also presents …


Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao Jan 2013

Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao

Theses and Dissertations--Electrical and Computer Engineering

In immersive audio environments with distributed microphones, Independent Component Analysis (ICA) can be applied to uncover signals from a mixture of other signals and noise, such as in a cocktail party recording. ICA algorithms have been developed for instantaneous source mixtures and convolutional source mixtures. While ICA for instantaneous mixtures works when no delays exist between the signals in each mixture, distributed microphone recordings typically result various delays of the signals over the recorded channels. The convolutive ICA algorithm should account for delays; however, it requires many parameters to be set and often has stability issues. This thesis introduces the …


Use Of Hybrid Diffuse Optical Spectroscopies In Continuous Monitoring Of Blood Flow, Blood Oxygenation, And Oxygen Consumption Rate In Exercising Skeletal Muscle, Katelyn Gurley Jan 2012

Use Of Hybrid Diffuse Optical Spectroscopies In Continuous Monitoring Of Blood Flow, Blood Oxygenation, And Oxygen Consumption Rate In Exercising Skeletal Muscle, Katelyn Gurley

Theses and Dissertations--Biomedical Engineering

This study combines noninvasive hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] with occlusive calibration for continuous measurement of absolute blood flow (BF), tissue blood oxygenation (StO2), and oxygen consumption rate (VO2) in exercising skeletal muscle. Subjects performed rhythmic dynamic handgrip exercise, while an optical probe connected to a hybrid NIRS/DCS flow-oximeter directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO2], [Hb], and [tHb]), StO2, relative BF (rBF), and relative VO2 (rVO2) in the forearm flexor muscles. Absolute baseline BF and …