Potassium Efflux From Myocardial Cells Induced By Defibrillator Shock, M J. Niebauer, L A. Geddes, Charles F. Babbs Jan 1986

Potassium Efflux From Myocardial Cells Induced By Defibrillator Shock, M J. Niebauer, L A. Geddes, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

A transient, dose-dependent cardiac depression was produced by defibrillator shocks in an isolated, working canine heart preparation perfused with oxygenated arterial blood from a support dog. Accompanying this depression was an efflux of potassium (K+ ), forced out of the myocardial cells by the passage of defibrillating current. The transient increase in extracellular K + concentration was recorded graphically in the venous outflow. It was found that 5-msec rectangular wave shocks, from three to ten times defibrillatory current threshold, released doserelated pulses of K+ . We conclude that because extracellular K + is a myocardial depressant, at least part of …


Relationship Of Blood Pressure And Flow During Cpr To Chest Compression Amplitude: Evidence For An Effective Compression Threshold, Charles F. Babbs, W D. Voorhees, K R. Fitzgerald, H R. Holmes, L A. Geddes Jan 1983

Relationship Of Blood Pressure And Flow During Cpr To Chest Compression Amplitude: Evidence For An Effective Compression Threshold, Charles F. Babbs, W D. Voorhees, K R. Fitzgerald, H R. Holmes, L A. Geddes

Weldon School of Biomedical Engineering Faculty Publications

This study was conducted to investigate the importance of the depth of chest compression in producing effective cardiopulmonary resuscitation (CPR) in animals, as indicated by cardiac output and mean arterial blood pressure. Cardiac output was measured by a modified indicator dilution technique in 8 anesthetized dogs, 6 to 12 kg body weight, during repeated 2-minute episodes of electrically induced ventricular fibrillation and CPR provided by a mechanical chest compressor and ventilator (Thumper®). Chest compression exceeding a threshold value (x0) between 1.5 and 3.0 cm was required in each animal to produce measurable cardiac output. In particular, …


Therapeutic Indices For Transchest Defibrillator Shocks: Effective, Damaging, And Lethal Electrical Doses, Charles F. Babbs, Willis A. Tacker, John F. Vanvleet, Joe D. Bourland, Leslie A. Geddes Jan 1980

Therapeutic Indices For Transchest Defibrillator Shocks: Effective, Damaging, And Lethal Electrical Doses, Charles F. Babbs, Willis A. Tacker, John F. Vanvleet, Joe D. Bourland, Leslie A. Geddes

Weldon School of Biomedical Engineering Faculty Publications

Although prospective studies of defibrillator shock overdose cannot be performed in man, the therapeutic indices of various defibrillating current waveforms can be measured in animals. We determined the ratios TD50/ED50 and LD50/ ED50 (where TD50 = median "toxic" or damageinducing dose, ED50 = median effective or defibrillating dose, and LD50 = median lethal dose) as measures of the therapeutic index for damped sine wave defibrillator shocks in dogs. Death of an animal and/or any degree of cardiac damage found by gross or microscopic examination were defined as harmful effects of shock, analogous to drug toxicity. In terms of peak current, …


Evaluation Of The Operating Internal Resistance And Capacitance Of Intact Trapezoidal Waveform Defibrillators, Charles F. Babbs, Sj Whistler, La Geddes Jan 1980

Evaluation Of The Operating Internal Resistance And Capacitance Of Intact Trapezoidal Waveform Defibrillators, Charles F. Babbs, Sj Whistler, La Geddes

Weldon School of Biomedical Engineering Faculty Publications

No abstract provided.