Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Reconstruction Of Patient-Specific Bone Models From X-Ray Radiography, Hatem Amin Abdel Fattah El Dakhakhni Dec 2013

Reconstruction Of Patient-Specific Bone Models From X-Ray Radiography, Hatem Amin Abdel Fattah El Dakhakhni

Doctoral Dissertations

The availability of a patient‐specific bone model has become an increasingly invaluable addition to orthopedic case evaluation and planning [1]. Utilized within a wide range of specialized visualization and analysis tools, such models provide unprecedented wealth of bone shape information previously unattainable using traditional radiographic imaging [2]. In this work, a novel bone reconstruction method from two or more x‐ray images is described. This method is superior to previous attempts in terms of accuracy and repeatability. The new technique accurately models the radiological scene in a way that eliminates the need for expensive multi‐planar radiographic imaging systems. It is also …


Discrete Geometric Based Stress Analysis Of The Lumbar Soft Tissues From In Vivo Kinematics, Joseph W. Mitchell Aug 2013

Discrete Geometric Based Stress Analysis Of The Lumbar Soft Tissues From In Vivo Kinematics, Joseph W. Mitchell

Doctoral Dissertations

Back pain in the region of the lumbar spine has become an increasingly significant problem among individuals in the United States and is a leading cause of disability and missed work days. At present, efforts focused on treating both the symptoms and causes of low back pain have proven to be difficult, and researchers and clinicians still do not fully understand the most effective means for treating the symptoms. Utilizing a biomechanics approach, it is assumed that lower back pain is, at least in part, associated with an increased localized stress.

Current models used to determine stresses are typically based …


Dynamic Mutual Capacitive Sensor For Human Interactions., Jonathan William Huber May 2013

Dynamic Mutual Capacitive Sensor For Human Interactions., Jonathan William Huber

Doctoral Dissertations

This dissertation introduces the novel concept of removing the ground conductive plate by utilizing body capacitance as the ground in the capacitive sensor, whereby circuit pressure sensing can occur with only one plate and one dielectric. Additionally, body capacitance sensing was limited to a binary touch-no-touch output, whereas the method presented here can sense various applied pressures. The resulting circuit acts as an antenna that receives local capacitance signals from a human interaction.

The advantage of this design is that it allows for both proximity sensing and pressure sensing (once the body part is touching the dielectric material). This setup …