Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Biomedical Engineering and Bioengineering

4dct Analysis Of In-Vivo Carpal Kinematics During Fem, Manisha R. Mistry Sep 2021

4dct Analysis Of In-Vivo Carpal Kinematics During Fem, Manisha R. Mistry

Electronic Thesis and Dissertation Repository

A consensus, detailed understanding of carpal kinematics remains elusive. 4-dimensional CT (4DCT) is a validated modality capable of accurately studying in-vivokinematic motion. The objective of this work is to quantify normal, in-vivo kinematic motion of the carpus through a flexion-extension arc of motion using 4DCT. Ten healthy, un-injured volunteers underwent a 4DCT scanning protocol through a complete arc of flexion-extension motion. Kinematic changes in motion were quantified using helical axis motion data for each carpal bone. Helical axes were compared between bones and statistical analysis performed using repeated-measures ANOVA to identify difference in kinematic motion between bones (p<0.05). The carpus can be divided into four main kinematic blocks: the distal carpal block, the proximal carpal block and individual scaphoid and trapezial blocks. This work supports an additional segmentation of the trapezium from the distal carpal row, which suggests some modulation between the scaphoid and distal carpal row.


Navigation And Patient Specific Instrumentation In Shoulder Arthroplasty, Joseph Cavanagh Oct 2020

Navigation And Patient Specific Instrumentation In Shoulder Arthroplasty, Joseph Cavanagh

Electronic Thesis and Dissertation Repository

The humeral head osteotomy influences shoulder arthroplasty component height, version and neck shaft angle and therefore outcomes. The purpose of this study is to develop and utilize navigation to execute the osteotomy.

3D printed models were used to develop a navigation technique, and then to execute planned osteotomies. Free hand, fixed angle guide, patient specific guides, and real time navigation osteotomies were completed. The height, neck shaft angle and version were recorded. Also collected, were the planes of the guides once they were placed.

Navigation had significantly less error from the planned osteotomy in neck shaft angle versus all other …


A Biomechanical Investigation Into The Effect Of Experimental Design On Wrist Biomechanics And Contact Mechanics, Clare E. Padmore Aug 2020

A Biomechanical Investigation Into The Effect Of Experimental Design On Wrist Biomechanics And Contact Mechanics, Clare E. Padmore

Electronic Thesis and Dissertation Repository

The wrist is one of the most commonly injured joints, and injury can have serious sequelae if pathological healing ensues. Strides have been made to understand normal and pathological wrist biomechanics using experimental approaches, which has contributed to improved patient care. The present work advances our understanding of the influence of experimental techniques and joint motion measurement techniques on in-vitro wrist biomechanical cadaveric studies, and applies the knowledge learned to a common clinical entity of scapholunate insufficiency.

First, the relative contributions of the carpal rows to wrist motion were assessed, in addition to the identification of limitations of current biomechanical …


The Of Application Of 3d-Printing To Lumbar Spine Surgery, Andrew J. Kanawati Apr 2020

The Of Application Of 3d-Printing To Lumbar Spine Surgery, Andrew J. Kanawati

Electronic Thesis and Dissertation Repository

Rapid prototyping refers to the manufacturing process in which a three-dimensional (3D) digital model can be transformed into a physical model by layering material in the shape of successive cross sections atop of previously layers. Rapid prototyping has been increasing in popularity in the field of medicine and surgery due to the ability to personalize various aspects of patient care. The thesis will explore the use of rapid prototyping in lumbar spine surgery, aim to quantify the accuracy of medical imaging when relating to imaged structures and their corresponding models produced by rapid prototyping, and determine if complex patient-specific guides …


Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan Dec 2018

Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan

Electronic Thesis and Dissertation Repository

Reverse total shoulder arthroplasty (RTSA) is increasingly utilized in the aging population, with a growing list of surgical indications including rotator cuff tear arthropathy, proximal humerus fractures, and revision arthroplasty. Acromial insufficiency fractures following RTSA are poorly understood, difficult to diagnose, and associated with inferior clinical outcomes. There is limited knowledge in the literature regarding the etiology of post-operative acromial fractures. The purpose of this study is to evaluate the role of implant parameters on acromial strain following RTSA.

Using a cadaveric model, a custom designed modular RTSA system was implanted that allowed for evaluation of modifiable parameters including glenoid …


Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan Nov 2018

Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan

Electronic Thesis and Dissertation Repository

Tibiotalar arthrodesis is a surgical procedure, used for the treatment of end-stage ankle arthrosis and instability. There are dozens of described procedures in the literature, all with varying rates of success. Two of the most common reasons for reoperation in tibiotalar arthrodesis are nonunion and infection; few studies have established any associations between patient/surgical factors and reoperation for nonunion and infection.

The first part of this thesis focuses on determining the rate of reoperation to the ipsilateral lower limb and if any patient/surgical factors are associated with reoperation for nonunion and infection. The second part of this thesis turns attention …


The Role Of Scapular Morphology In Reverse Shoulder Arthroplasty, Ashish Gupta Dec 2016

The Role Of Scapular Morphology In Reverse Shoulder Arthroplasty, Ashish Gupta

Electronic Thesis and Dissertation Repository

Baseplate fixation in a reverse shoulder arthroplasty depends on adequate bone stock. In cases of severe glenoid bone loss and revision shoulder arthroplasty, deficiency of the glenoid vault compels the surgeon to attain screw fixation in the three columns of the scapula. The relationship of these columns demonstrated that the coracoid is closer to the lateral scapular pillar in females than in males. Significant gender dimorphism exists between the orientations of the three columns. The gender dimorphism is further evaluated by anthropometric measurements of the scapular body and the glenoid. The clinical significance lies in the ability to reconstruct the …


An Intra-Bone Axial Load Transducer: Development And Validation In An In-Vitro Radius Model, Nikolas K. Knowles, Michael Gladwell, Louis M. Ferreira Dec 2015

An Intra-Bone Axial Load Transducer: Development And Validation In An In-Vitro Radius Model, Nikolas K. Knowles, Michael Gladwell, Louis M. Ferreira

Surgery Publications

Background

Accurate measurement of forces through the proximal radius can assess the effects of some surgical procedures on radioulnar load sharing, but is difficult to achieve given the redundant loading nature of the musculoskeletal system. Previously reported devices have relied on indirect measurements that may alter articular joint location and function. An axial load transducer interposed in the diaphysis of the radius may accurately quantify unknown axial loads of the proximal radius, and maintain articular location.

Methods

An in-vitro radius model was developed by interposing an axial load transducer in the diaphysis of the proximal radius. Static loads of 20, …


The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …


Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad Aug 2013

Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad

Electronic Thesis and Dissertation Repository

Pedicle screws are commonly utilized in spinal surgery; however, traditional designs often do not provide adequate fixation in osteoporotic spines. The objective of this thesis was to develop a novel expanding screw for use in osteoporotic lumbar pedicles. Helical screws capable of expanding post insertion were built on a rapid prototype machine. A materials testing machine performed axial load to failure tests in both Sawbones and cadaveric specimens comparing the new design to traditional screws (rate = 10mm/min to 20 mm). Output parameters included yield load, ultimate load, stiffness, energy to failure and total energy. The expanding screw showed a …