Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Quantifying Cross-Scatter Contamination In Biplane Fluoroscopy Motion Analysis Systems, Janelle A. Cross, Ben Mchenry, Taly Gilat-Schmidt Oct 2015

Quantifying Cross-Scatter Contamination In Biplane Fluoroscopy Motion Analysis Systems, Janelle A. Cross, Ben Mchenry, Taly Gilat-Schmidt

Biomedical Engineering Faculty Research and Publications

Biplane fluoroscopy is used for dynamic in vivo three-dimensional motion analysis of various joints of the body. Cross-scatter between the two fluoroscopy systems may limit tracking accuracy. This study measured the magnitude and effects of cross-scatter in biplane fluoroscopic images. Four cylindrical phantoms of 4-, 6-, 8-, and 10-in. diameter were imaged at varying kVp levels to determine the cross-scatter fraction and contrast-to-noise ratio (CNR). Monte Carlo simulations quantified the effect of the gantry angle on the cross-scatter fraction. A cadaver foot with implanted beads was also imaged. The effect of cross-scatter on marker-based tracking accuracy was investigated. Results demonstrated …


Biplanar Fluoroscopic Analysis Of In Vivo Hindfoot Kinematics During Ambulation, Janelle Ann Cross Jul 2015

Biplanar Fluoroscopic Analysis Of In Vivo Hindfoot Kinematics During Ambulation, Janelle Ann Cross

Dissertations (1934 -)

The overall goal of this project was to develop and validate a biplanar fluoroscopic system and integrated software to assess hindfoot kinematics. Understanding the motion of the foot and ankle joints may lead to improved treatment methods in persons with foot and ankle pathologies. During gait analysis, skin markers are placed on the lower extremities, which are defined as four rigid-body segments with three joints representing the hip, knee and ankle. This method introduces gross assumptions on the foot and severely limits the analysis of in depth foot mechanics. Multi-segmental models have been developed, but are susceptible to skin motion …


Sagittal Subtalar And Talocrural Joint Assessment With Weight-Bearing Fluoroscopy During Barefoot Ambulation, Ben Mchenry, Emily L. Exten, Jason Long, Brian Law, Richard Marks, Gerald F. Harris Apr 2015

Sagittal Subtalar And Talocrural Joint Assessment With Weight-Bearing Fluoroscopy During Barefoot Ambulation, Ben Mchenry, Emily L. Exten, Jason Long, Brian Law, Richard Marks, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

Background: Identifying talar position during ambulation has proved difficult as the talus lacks palpable landmarks for skin marker placement and more invasive methodologies such as bone pins are not practical for most clinical subjects. A fluoroscopic motion system was used to track the talus and calcaneus, allowing kinematic analysis of the talocrural and subtalar joints.

Methods: Thirteen male subjects (mean age 22.9 ± 3.0 years) previously screened for normal gait were tested. A fluoroscopy unit was used to collect images at 120 fps during stance. Sagittal motion of the talocrural and subtalar joints were analyzed.

Results: The intersubject mean and …