The Effects Of Gantry Tilt On Breast Dose And Image Noise In Cardiac Ct, Michael Hoppe, Diksha Gandhi, Grant Stevens, Dennis Foley, Taly Gilat-Schmidt
The Effects Of Gantry Tilt On Breast Dose And Image Noise In Cardiac Ct, Michael Hoppe, Diksha Gandhi, Grant Stevens, Dennis Foley, Taly Gilat-Schmidt
Biomedical Engineering Faculty Research and Publications
Purpose:
This study investigated the effects of tilted-gantry acquisition on image noise and glandular breast dose in females during cardiac computed tomography (CT) scans. Reducing the dose to glandular breast tissue is important due to its high radiosensitivity and limited diagnostic significance in cardiac CT scans.
Methods:
Tilted-gantry acquisition was investigated through computer simulations and experimental measurements. Upon IRB approval, eight voxelized phantoms were constructed from previously acquired cardiac CT datasets. Monte Carlo simulations quantified the dose deposited in glandular breast tissue over a range of tilt angles. The effects of tilted-gantry acquisition on breast dose were measured on a …
Reducing Radiation Dose To The Female Breast During Ct Coronary Angiography: A Simulation Study Comparing Breast Shielding, Angular Tube Current Modulation, Reduced Kv, And Partial Angle Protocols Using An Unknown-Location Signal-Detectability Metric, Franco Rupcich, Andreu Badal, Lucretiu M. Popescu, Iacovos Kyprianou, Taly Gilat Schmidt
Reducing Radiation Dose To The Female Breast During Ct Coronary Angiography: A Simulation Study Comparing Breast Shielding, Angular Tube Current Modulation, Reduced Kv, And Partial Angle Protocols Using An Unknown-Location Signal-Detectability Metric, Franco Rupcich, Andreu Badal, Lucretiu M. Popescu, Iacovos Kyprianou, Taly Gilat Schmidt
Biomedical Engineering Faculty Research and Publications
Purpose:
The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.
Methods:
The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and …