Flash Radiotherapy: Skin Pigmentation As A Non-Invasive Indicator For Radiation-Induced Damage, Brady Mccallister Jun 2021

Flash Radiotherapy: Skin Pigmentation As A Non-Invasive Indicator For Radiation-Induced Damage, Brady Mccallister

ENGS 88 Honors Thesis (AB Students)

FLASH ultra-high dose rate radiotherapy (RT) is one of the most rapidly growing subfields of radiation oncology today due to its potential to increase the limits of the therapeutic ratio. The FLASH effect, which includes heightened normal tissue sparing paired with iso-effective tumor cell killing, has been literature documented, in a limited manner, in rodent models, a few large animals, and one clinical patients.

A porcine-based experiment was conducted to test the effects of FLASH RT on normal tissue compared to conventional (CONV) RT. A clinical linear accelerator (LINAC) was reversibly converted to be capable of FLASH RT. A female …


Utilizing Neural Networks And Wearables To Quantify Hip Joint Angles And Moments During Walking And Stair Ascent, Megan V. Mccabe Jun 2020

Utilizing Neural Networks And Wearables To Quantify Hip Joint Angles And Moments During Walking And Stair Ascent, Megan V. Mccabe

ENGS 88 Honors Thesis (AB Students)

Wearable sensors were leveraged to develop two methods for computing hip joint angles and moments during walking and stair ascent that are more portable than the gold standard. The Insole-Standard (I-S) approach replaced force plates with force-measuring insoles and achieved results that match the curvature of results from similar studies. Peaks in I-S kinetic results are high due to error induced by applying the ground reaction force to the talus. The Wearable-ANN (W-A) approach combines wearables with artificial neural networks to compute the same results. Compared against the I-S, the W-A approach performs well (average rRMSE = 18%, R2 …


A Physical And Computational Reverse-Engineering Approach To Determine Dimensional Change And Its Relationship To Oxidation In Retrieved Orthopedic Implants, Josephine Kalshoven Jun 2019

A Physical And Computational Reverse-Engineering Approach To Determine Dimensional Change And Its Relationship To Oxidation In Retrieved Orthopedic Implants, Josephine Kalshoven

ENGS 88 Honors Thesis (AB Students)

Oxidation of the Ultra-High Molecular Weight Polyethylene (UHMWPE) tibial inserts of total knee arthroplasty devices is a major factor underlying multiple modes of failure for these devices, including delamination, wear, and fracture. Previous research has demonstrated that oxidation of UHMWPE is driven by a high concentration of free radicals in the polyethylene. However, even new devices created with undetectable amounts of free radicals are oxidizing in vivo. One theory is that, in the absence of residual free radicals, oxidation is facilitated by absorbed species (e.g. lipids, ROS) delivered or exacerbated by contact stress. However, no method exists to comprehensively …


Singular Value Decomposition Metrics Show Limitations Of Detector Design In Diffuse Fluorescence Tomography, Frederic Leblond, Kenneth M. Tichauer, Brian W. Pogue Dec 2010

Singular Value Decomposition Metrics Show Limitations Of Detector Design In Diffuse Fluorescence Tomography, Frederic Leblond, Kenneth M. Tichauer, Brian W. Pogue

Dartmouth Scholarship

The spatial resolution and recovered contrast of images reconstructed from diffuse fluorescence tomography data are limited by the high scattering properties of light propagation in biological tissue. As a result, the image reconstruction process can be exceedingly vulnerable to inaccurate prior knowledge of tissue optical properties and stochastic noise. In light of these limitations, the optimal source-detector geometry for a fluorescence tomography system is non-trivial, requiring analytical methods to guide design. Analysis of the singular value decomposition of the matrix to be inverted for image reconstruction is one potential approach, providing key quantitative metrics, such as singular image mode spatial …