Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Clemson University

Series

Lumped-parameter network

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Biomedical Engineering and Bioengineering

A Protocol For Coupling Volumetrically Dynamic In Vitro Experiments To Numerical Physiology Simulation For A Hybrid Cardiovascular Model, Abraham Umo, Ethan Kung Oct 2022

A Protocol For Coupling Volumetrically Dynamic In Vitro Experiments To Numerical Physiology Simulation For A Hybrid Cardiovascular Model, Abraham Umo, Ethan Kung

Publications

Objective: The Physiology Simulation Coupled Experiment (PSCOPE) is a hybrid modeling framework that enables a physical fluid experiment to operate in the context of a closed-loop computational simulation of cardiovascular physiology. Previous PSCOPE methods coupled rigid experiments to a lumped parameter network (LPN) of physiology but are incompatible with volumetrically dynamic experiments where fluid volume varies periodically. We address this limitation by introducing a method capable of coupling rigid, multi-branch, and volumetrically dynamic in-vitro experiments to an LPN. Methods: Our proposed method utilizes an iterative weighted-averaging algorithm to identify the unique solution waveforms for a given PSCOPE model. We confirm …


Superior Performance Of Continuous Over Pulsatile Flow Ventricular Assist Devices In The Single Ventricle Circulation: A Computational Study, Tyler Schmidt, David Rosenthal, Olaf Reinhartz, Kirk Riemer, Fei He, Tain-Yen Hsia, Alison Marsden, Ethan Kung Feb 2017

Superior Performance Of Continuous Over Pulsatile Flow Ventricular Assist Devices In The Single Ventricle Circulation: A Computational Study, Tyler Schmidt, David Rosenthal, Olaf Reinhartz, Kirk Riemer, Fei He, Tain-Yen Hsia, Alison Marsden, Ethan Kung

Publications

This study compares the physiological responses of systemic-to-pulmonary shunted single ventricle patients to pulsatile and continuous flow ventricular assist devices (VADs). Performance differences between pulsatile and continuous flow VADs have been clinically observed, but the underlying mechanism remains poorly understood. Six systemic-to-pulmonary shunted single ventricle patients (mean BSA=0.30 m2) were computationally simulated using a lumped-parameter network tuned to match patient specific clinical data. A first set of simulations compared current clinical implementation of VADs in single ventricle patients. A second set modified pulsatile flow VAD settings with the goal to optimize cardiac output (CO). For all patients, the best-case continuous …