Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Studying Mass And Mechanical Property Changes During The Degradation Of A Bioadhesive With Mass Tracking, Rheology And Magnetoelastic (Me) Sensors, Zhongtian Zhang Jan 2018

Studying Mass And Mechanical Property Changes During The Degradation Of A Bioadhesive With Mass Tracking, Rheology And Magnetoelastic (Me) Sensors, Zhongtian Zhang

Dissertations, Master's Theses and Master's Reports

In this research, the degradable polymer 4-arm poly (ethylene glycol)-glutaric acid-dopamine (PEG-GA-DM4) was synthesized. The degradation behavior of crosslinked PEG-GA-DM4 bioadhesive was studied with mass tracking, oscillatory rheology, and magnetoelastic (ME) sensors. Changes in mechanical properties were correlated with both dry mass and wet mass changes during the degradation. The results indicate that the loss of mechanical property in the bioadhesive can take place without losing the dry mass. The mass loss profile cannot describe the degradation behavior completely. In addition to studying the degradation of PEG-GA-DM4, this research also confirms the application of ME …


Wireless Implantable Magnetoelastic Sensors And Actuators For Biomedical Applications, Andrew Derouin Jan 2016

Wireless Implantable Magnetoelastic Sensors And Actuators For Biomedical Applications, Andrew Derouin

Dissertations, Master's Theses and Master's Reports

Magnetoelastic sensors represent a low-cost wireless and battery-less method for monitoring parameters in embedded or implanted applications; however, some limitations still exist preventing their commercial implementation. Presented in this work are a variety of studies that are aimed at improving the feasibility of magnetoelastic materials for sensing and actuating applications. Magnetoelastic resonant sensors of non-standard geometries were investigated to determine if geometry could play a role on the sensitivity of the sensor response to mass loading. It was shown that a significant increase in sensitivity could be achieved by using triangular sensors rather than standard rectangular strips. A method for …


Design And Application Of Wireless Passive Magnetoelastic Resonance And Magnetoharmonic Force Sensors, Brandon D. Pereles Jan 2014

Design And Application Of Wireless Passive Magnetoelastic Resonance And Magnetoharmonic Force Sensors, Brandon D. Pereles

Dissertations, Master's Theses and Master's Reports - Open

The objective of the work described in this dissertation is the development of new wireless passive force monitoring platforms for applications in the medical field, specifically monitoring lower limb prosthetics. The developed sensors consist of stress sensitive, magnetically soft amorphous metallic glass materials. The first technology is based on magnetoelastic resonance. Specifically, when exposed to an AC excitation field along with a constant DC bias field, the magnetoelastic material mechanically vibrates, and may reaches resonance if the field frequency matches the mechanical resonant frequency of the material. The presented work illustrates that an applied loading pins portions of the strip, …