Cobalt Ferrite Nanoparticles Fabricated Via Co-Precipitation In Air: Overview Of Size Control And Magnetic Properties, Dennis Toledo Nov 2015

Cobalt Ferrite Nanoparticles Fabricated Via Co-Precipitation In Air: Overview Of Size Control And Magnetic Properties, Dennis Toledo

FIU Electronic Theses and Dissertations

Cobalt Ferrite has important, size-dependent magnetic properties. Consequently, an overview of particle size is important. Co-precipitation in air was the fabrication method used because it is comparatively simple and safe. The effects of three different reaction times including 1, 2, 3 hour(s) on particle size were compared. Also, the effectiveness of three different capping agents (Oleic Acid, Polyvinylpyrollidone (PVP), and Trisodium Citrate) in reducing aggregation and correspondingly particle size were examined. Using Welch’s analysis of variance (ANOVA) and the relevant post hoc tests, there was no significant difference (p=0.05) between reaction times of 1 hour and 2 hours, but there …


Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer Nov 2015

Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Many studies aim to understand the fundamentals of kicking commonly displayed by soccer players [4,6,10,16,17,18,24,25,28,29,30,34,36,38,40]. Of those studies, most are limited to a two-dimensional (2D) analysis using high-speed cameras for position tracking or utilizing electromyography to observe the activity of select muscles [4,6,18,25,29,36]. The few studies that investigate kicking using a three-dimensional (3D) model are limited in their position tracking capabilities and focus mainly on joint flexion potentials and foot speed.

This dissertation is a comprehensive biomechanical analysis (kinematic and EMG) of the field-goal place-kicking techniques of four elite kickers in American football. Data were compared and contrasted with ball …


Computational Characterization Of Exogenous Micrornas That Can Be Transferred Into Human Circulation, Jiang Shu, Kevin Chiang, Janos Zempleni, Juan Cui Nov 2015

Computational Characterization Of Exogenous Micrornas That Can Be Transferred Into Human Circulation, Jiang Shu, Kevin Chiang, Janos Zempleni, Juan Cui

School of Computing: Faculty Publications

MicroRNAs have been long considered synthesized endogenously until very recent discoveries showing that human can absorb dietary microRNAs from animal and plant origins while the mechanism remains unknown. Compelling evidences of microRNAs from rice, milk, and honeysuckle transported to human blood and tissues have created a high volume of interests in the fundamental questions that which and how exogenous microRNAs can be transferred into human circulation and possibly exert functions in humans. Here we present an integrated genomics and computational analysis to study the potential deciding features of transportable microRNAs. Specifically, we analyzed all publicly available microRNAs, a total of …


Mattrack: A Matlab-Based Quantitative Image Analysis Platform For Investigating Real-Time Photo-Converted Fluorescent Signals In Live Cells, Jane Courtney, Elena Woods, Dimitri Scholz, William Hall, Virginie Gautier Oct 2015

Mattrack: A Matlab-Based Quantitative Image Analysis Platform For Investigating Real-Time Photo-Converted Fluorescent Signals In Live Cells, Jane Courtney, Elena Woods, Dimitri Scholz, William Hall, Virginie Gautier

Articles

We introduce here MATtrack, an open source MATLAB-based computational platform developed to process multi-Tiff files produced by a photo-conversion time lapse protocol for live cell fluorescent microscopy. MATtrack automatically performs a series of steps required for image processing, including extraction and import of numerical values from Multi-Tiff files, red/green image classification using gating parameters, noise filtering, background extraction, contrast stretching and temporal smoothing. MATtrack also integrates a series of algorithms for quantitative image analysis enabling the construction of mean and standard deviation images, clustering and classification of subcellular regions and injection point approximation. In addition, MATtrack features a simple user …


The Role Of Biological Fluid And Dynamic Flow In The Behavior And Cellular Interactions Of Gold Nanoparticles, Emily K. Breitner, Saber M. Hussain, Kristen K. Comfort Sep 2015

The Role Of Biological Fluid And Dynamic Flow In The Behavior And Cellular Interactions Of Gold Nanoparticles, Emily K. Breitner, Saber M. Hussain, Kristen K. Comfort

Chemical and Materials Engineering Faculty Publications

Background: Due to their distinctive physicochemical properties, nanoparticles (NPs) have proven to be extremely advantageous for product and application development, but are also capable of inducing detrimental outcomes in biological systems. Standard in vitro methodologies are currently the primary means for evaluating NP safety, as vast quantities of particles exist that require appraisal. However, cell-based models are plagued by the fact that they are not representative of complex physiological systems. The need for a more accurate exposure model is highlighted by the fact that NP behavior and subsequent bioresponses are highly dependent upon their surroundings. Therefore, standard in vitro models …


Portable Polarimetric Fiber Stress Sensor System For Visco-Elastic And Biomimetic Material Analysis, Mark C. Harrison, Andrea M. Armani May 2015

Portable Polarimetric Fiber Stress Sensor System For Visco-Elastic And Biomimetic Material Analysis, Mark C. Harrison, Andrea M. Armani

Engineering Faculty Articles and Research

Non-destructive materials characterization methods have significantly changed our fundamental understanding of material behavior and have enabled predictive models to be developed. However, the majority of these efforts have focused on crystalline and metallic materials, and transitioning to biomaterials, such as tissue samples, is non-trivial, as there are strict sample handling requirements and environmental controls which prevent the use of conventional equipment. Additionally, the samples are smaller and more complex in composition. Therefore, more advanced sample analysis methods capable of operating in these environments are needed. In the present work, we demonstrate an all-fiber-based material analysis system based on optical polarimetry. …


Modeling The Contributions Of Hand Loads To Cervical Spine Compressive Forces, Mohamed R.S. Amar May 2015

Modeling The Contributions Of Hand Loads To Cervical Spine Compressive Forces, Mohamed R.S. Amar

Department of Biological Systems Engineering: Dissertations and Theses

The purpose for this study is threefold. All involve single handed lifting tasks where the height of the lifted object, the distance of the lifted object from the body, and the angle of the lift relative to the body were varied. First, examine the activity of each of the shared musculature of selected shared muscles between the shoulder and cervical spine. Second, attempt to empirically model the activations of the shared muscles. Third, to understand the relationship between the active and antagonistic contraction. Finally, to establish a biomechanical model to estimate the compressive forces on the cervical spine.

Ten subjects …


Development Of Point-Of-Care Testing Sensors For Biomarker Detection, Xuena Zhu Apr 2015

Development Of Point-Of-Care Testing Sensors For Biomarker Detection, Xuena Zhu

FIU Electronic Theses and Dissertations

Point-of-care testing (POCT) is defined as medical testing at or near the site of patient care and has become a critical component of the diagnostic industry. POCT has many advantages over tests in centralized laboratories including small reagent volumes, small size, rapid turnaround time, cost-effectiveness, low power consumption and functional integration of multiple devices. Paper-based POCT sensors are a new alternative technology for fabricating simple, low-cost, portable and disposable analytical devices for clinical diagnosis.

The focus of this dissertation was to develop simple, rapid and low cost paper-based POCT sensors with high sensitivity and portability for disease biomarker detection. Lateral …


Effects Of Three Dry Powder Inhalers On Deposition Of Aerosolized Medicine In The Human Oral-Pharyngeal-Laryngeal Regions, Mohammed Ali Feb 2015

Effects Of Three Dry Powder Inhalers On Deposition Of Aerosolized Medicine In The Human Oral-Pharyngeal-Laryngeal Regions, Mohammed Ali

Technology Faculty Publications and Presentations

The dry powder inhaler (DPI) is a popular, effective and convenient drug delivery device for inhalation therapy to treat asthma. However, a large quantity (approximately 54%) of inhaled aerosols deposit in the oropharyngeal region. Deposition in this region is undesirable because it provides minimum therapeutic benefits and has adverse localized or systemic side effects. This study reports a method of examining electrostatic charge effects on deposition of three DPI aerosols (Spiriva Handihaler, Advair Diskus, and Pulmicort Turbohaler) in a cadaver-based cast of the human oral-pharyngeal-laryngeal (OPL) regions. Experimental aerosols were generated from the three commercially available …


Characterization Of Closed Head Impact Injury In Rat, Yi Hua, Praveen Akula, Matthew Kelso, Linxia Gu Jan 2015

Characterization Of Closed Head Impact Injury In Rat, Yi Hua, Praveen Akula, Matthew Kelso, Linxia Gu

Department of Mechanical and Materials Engineering: Faculty Publications

The closed head impact (CHI) rat models are commonly used for studying the traumatic brain injury. The impact parameters vary considerably among different laboratories, making the comparison of research findings difficult. In this work, numerical CHI experiments were conducted to investigate the sensitivities of intracranial responses to various impact parameters (e.g., impact depth, velocity, and position; impactor diameter, material, and shape). A three-dimensional finite element rat head model with anatomical details was subjected to impact loadings. Results revealed that impact depth and impactor shape were the two leading factors affecting intracranial responses.The influence of impactor diameter was region-specific and an …


Blast-Induced Mild Traumatic Brain Injury Through Ear Canal: A Finite Element Study, Praveen Akula, Yi Hua, Linxia Gu Jan 2015

Blast-Induced Mild Traumatic Brain Injury Through Ear Canal: A Finite Element Study, Praveen Akula, Yi Hua, Linxia Gu

Department of Mechanical and Materials Engineering: Faculty Publications

Purpose The role of ear canal in transmitting blast waves to the brain is not clear. The goal of this work is to characterize the influence of ear canal on blast-induced mild traumatic brain injury through a computational approach.

Methods A three-dimensional human head model with single-side ear canal details was reconstructed from computed tomography images. The ear canal was positioned either facing the incident blast wave or facing away from the blast wave.

Results The blast wave-head interaction has demonstrated that the overpressure within the ear canal was substantially amplified when the ear directly faced the blast wave. When …