Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Biomedical Engineering and Bioengineering

Under-Sampled Reconstruction Techniques For Accelerated Magnetic Resonance Imaging, Mohammad H. Kayvanrad Dec 2013

Under-Sampled Reconstruction Techniques For Accelerated Magnetic Resonance Imaging, Mohammad H. Kayvanrad

Electronic Thesis and Dissertation Repository

Due to physical and biological constraints and requirements on the minimum resolution and SNR, the acquisition time is relatively long in magnetic resonance imaging (MRI). Consequently, a limited number of pulse sequences can be run in a clinical MRI session because of constraints on the total acquisition time due to patient comfort and cost considerations. Therefore, it is strongly desired to reduce the acquisition time without compromising the reconstruction quality. This thesis concerns under-sampled reconstruction techniques for acceleration of MRI acquisitions, i.e., parallel imaging and compressed sensing.

While compressed sensing MRI reconstructions are commonly regularized by penalizing the decimated wavelet …


The Development Of A New Dry Powder Inhaler, Xi Zhang Dec 2013

The Development Of A New Dry Powder Inhaler, Xi Zhang

Electronic Thesis and Dissertation Repository

A new dry powder inhaler (DPI) for respiratory drug delivery was developed. This novel device is characterized by a micro-dose, passive delivery and multiple doses individually sealed in one replaceable disk. The micro-dose delivery system uses only a small amount of excipient, such as 2-3mg lactose, thereby improving the drug delivery efficiency. The passive delivery method eliminates the need for coordination between breath and device actuation such as the pressure metered dose inhaler (pMDI). Finally, 14 doses on a disk reduce the need to frequently change dosage disks. In addition, each dose is effectively protected by a blister package to …


Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves Aug 2013

Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves

Electronic Thesis and Dissertation Repository

Distal radius fractures are prevalent, debilitating, and costly. This thesis conducts an in vitro investigation of these injuries, examining the role of static muscle loading on fracture threshold measures (i.e., force, impulse, energy). Initially, an impact apparatus and custom LabVIEW colour-thresholding program were designed and assessed for repeatability and accuracy in quantifying fracture measures and impact kinematics. These tools were then used to test six pairs of cadaveric forearms, with static muscle loads simulated in one specimen from each pair. Distal radius fractures were achieved in 5 pairs, with perilunate dislocations in the remaining pair. None of the …


Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad Aug 2013

Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad

Electronic Thesis and Dissertation Repository

Pedicle screws are commonly utilized in spinal surgery; however, traditional designs often do not provide adequate fixation in osteoporotic spines. The objective of this thesis was to develop a novel expanding screw for use in osteoporotic lumbar pedicles. Helical screws capable of expanding post insertion were built on a rapid prototype machine. A materials testing machine performed axial load to failure tests in both Sawbones and cadaveric specimens comparing the new design to traditional screws (rate = 10mm/min to 20 mm). Output parameters included yield load, ultimate load, stiffness, energy to failure and total energy. The expanding screw showed a …