Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Biomedical Engineering and Bioengineering

Sol Retractor: Rapidly Deployable Film-Based C-Section Retractor, Casey Lee, Silas Cleveland, Jose Dolores Valdivieso, Joseph Perks Jun 2020

Sol Retractor: Rapidly Deployable Film-Based C-Section Retractor, Casey Lee, Silas Cleveland, Jose Dolores Valdivieso, Joseph Perks

Honors Theses

Cesarean Sections (C-sections), a surgery conducted for baby delivery, can be divided into four distinct categories; Category 1 and 2 are considered emergency c-sections, and Category 3 and 4 are scheduled c-sections [2]. A comparative study from 2016 analyzed the difference of need for postoperative treatment between the Collins or the Alexis O retractor ( n = 100). The Alexis O C-Section retractor resulted in 19% of women requiring postoperative treatment, including medication, monitoring, and an extended stay at the hospital. The Collins resulted in 43% of the patients requiring postoperative treatment (p = 0.001) [5]. In emergency C-sections, surgical …


The Theia Soteria: Alternative Design For Safer Initial Entry During Laparoscopic Procedures, Kayla Dubois, Patrick Ryan, Madelyn Joanis Jun 2019

The Theia Soteria: Alternative Design For Safer Initial Entry During Laparoscopic Procedures, Kayla Dubois, Patrick Ryan, Madelyn Joanis

Honors Theses

Laparoscopic procedures account for 15 million surgeries worldwide [1], with the initial entry into the peritoneal cavity accounting for 33-50% of all major laparoscopic complications [7]. This initial entry is the most dangerous as surgeons must enter the cavity using a sharp object with no visibility and space between the outer surface of the cavity and internal tissues. During the initial entry into the peritoneal cavity, the patients undergoing laparoscopic procedures are at a high risk for damage to internal organs and vasculature, necessitating the development of a device to protect these internal tissues and increase patient safety.


Design Of A Double-Dose Epinephrine Auto-Injector Using 3d-Printing, Timothy Calvin Sheehan Jun 2015

Design Of A Double-Dose Epinephrine Auto-Injector Using 3d-Printing, Timothy Calvin Sheehan

Honors Theses

This project involved the design and prototyping of an epinephrine auto-injector capable of administering two separate doses. Epinephrine auto-injectors are used in the treatment of patients undergoing anaphylaxis, an allergic reaction causing the restriction of airways and a drop in blood pressure. The timely administration of epinephrine counteracts these symptoms and can be lifesaving. Currently the only devices available to consumers administer one unit dose of epinephrine and are then no longer usable. In 30% of cases where patients undergo these symptoms a second dose of epinephrine is required. My design was based partially off the concept behind currently available …


History Of Concussion Research In American Football, Timothy Hersey Jun 2013

History Of Concussion Research In American Football, Timothy Hersey

Honors Theses

Concussions have been the topic of discussion in the news and media in recent years for their profound impact on today’s sport industry. Athletes have become bigger, faster, and stronger then in the past, increasing the chance of injury. This can been seen in all sports. Contact sports specifically have seen a rise in mild traumatic brain injuries (MTBIs) over the years. Extensive research has been done to determine the causes of concussion, the short and long term effects of brain injury, and better ways to reduce the risk in sports. Concussion research in athletics has mainly focused on American …


Studying The Material Properties Of The Embryonic Chicken Heart, Kyra Burnett Jun 2013

Studying The Material Properties Of The Embryonic Chicken Heart, Kyra Burnett

Honors Theses

Congenital heart disease is the number one cause of birth defects in the United States, affecting approximately 40,000 newborns each year. Research has shown that serious structural defects of the heart can occur due to abnormal looping. Looping refers to the positional and morphological changes of the early embryo heart and is divided into different phases. Although progress has been made in identifying the genetic processes behind heart looping, the forces involved with the developmental process are still not fully understood. In this research, the chicken embryo heart was used as the experimental model and certain material properties were characterized. …