Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- AIDS (1)
- Autoantibody (1)
- Autoimmunity (1)
- Axial load transducer (1)
- Bone-bridge (1)
-
- Brachytherapy (1)
- Breast radiotherapy (1)
- Cancer (1)
- Chemoradiation therapy (1)
- Cytokine (1)
- Electronic Portal Imaging (1)
- Esophageal cancer (1)
- Esophagectomy (1)
- Forearm loading (1)
- Headless compression screw (1)
- Interstitial Lung (1)
- Irradiation (1)
- Joint loading (1)
- Operative treatment (1)
- Radial head (1)
- Radiocapitellar joint (1)
- Radioulnar load sharing (1)
- Robot Assisted (1)
- Scaphoid fractures (1)
- Ultrasound (1)
Articles 1 - 6 of 6
Full-Text Articles in Biomedical Engineering and Bioengineering
An Intra-Bone Axial Load Transducer: Development And Validation In An In-Vitro Radius Model, Nikolas K. Knowles, Michael Gladwell, Louis M. Ferreira
An Intra-Bone Axial Load Transducer: Development And Validation In An In-Vitro Radius Model, Nikolas K. Knowles, Michael Gladwell, Louis M. Ferreira
Surgery Publications
Background
Accurate measurement of forces through the proximal radius can assess the effects of some surgical procedures on radioulnar load sharing, but is difficult to achieve given the redundant loading nature of the musculoskeletal system. Previously reported devices have relied on indirect measurements that may alter articular joint location and function. An axial load transducer interposed in the diaphysis of the radius may accurately quantify unknown axial loads of the proximal radius, and maintain articular location.
Methods
An in-vitro radius model was developed by interposing an axial load transducer in the diaphysis of the proximal radius. Static loads of 20, …
A Comparison Of Two Headless Compression Screws For Operative Treatment Of Scaphoid Fractures, Ruby Grewal, Joseph Assini, David Sauder, Louis Ferreira, Jim Johnson, Kenneth Faber
A Comparison Of Two Headless Compression Screws For Operative Treatment Of Scaphoid Fractures, Ruby Grewal, Joseph Assini, David Sauder, Louis Ferreira, Jim Johnson, Kenneth Faber
Surgery Publications
PURPOSE: The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw.
METHODS: Sixteen (8 pairs; 6 female, 2 male) cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contralateral scaphoid designated to receive the opposite. Guide wires were inserted under fluoroscopic control. Following transverse osteotomy, the distal and proximal fragments were placed on either side of a custom load cell, to measure interfragmentary compression. Screws were placed …
A Review Of Autoimmune Diseases Associated With Cancer, Patricia Tai, Edward Yu, Kurian Joseph, Thomas Miale
A Review Of Autoimmune Diseases Associated With Cancer, Patricia Tai, Edward Yu, Kurian Joseph, Thomas Miale
Oncology Publications
The focus of this review is on the relationships between autoimmune diseases and cancer from two closely related perspectives: 1.Those autoimmune diseases which are often associated with malignancies. 2.Those prevalent cancers which may increase the risks of developing autoimmune disorders. The review concludes with a brief discussion of some selected innovative approaches to cancer immunotherapy.
Robot Assisted Ultrasound Imaged Guided Interstitial Lung Brachytherapy In A Porcine Model, Richard A. Malthaner, Edward Yu, Jerry J. Battista, Chris Blake, Donal Downey, Aaron Fenster
Robot Assisted Ultrasound Imaged Guided Interstitial Lung Brachytherapy In A Porcine Model, Richard A. Malthaner, Edward Yu, Jerry J. Battista, Chris Blake, Donal Downey, Aaron Fenster
Oncology Presentations
We set out to see if permanent interstitial brachytherapy seeds could be safely and reproducibly inserted thoracoscopicaly with the ZEUS Robotic system and intraoperative ultrasound into in-vivo porcine lungs.
Evaluation Of Intra-And Inter-Fraction Motion In Breast Radiotherapy Using Electronic Portal Imaging Cine Loops, Chrison Lee, Edward Yu, Tomas Kron
Evaluation Of Intra-And Inter-Fraction Motion In Breast Radiotherapy Using Electronic Portal Imaging Cine Loops, Chrison Lee, Edward Yu, Tomas Kron
Oncology Presentations
Parallel tangent breast irradiation is commonly used postbreast conservation surgery for early breast cancer patient without lymph node involvement to improve local disease control. Intra-fractional and inter-fractional variabilities are often presented in daily treatment setup. The present pilot study used Electronic Portal Imaging (EPI) to evaluate intra-and inter-fraction motion in patients undergoing simple breast tangent radiotherapy.
Is Extended Volume Of External Beam Irradiation Beneficial In Post-Esophagectomy High Risk Patients Receiving Combined Chemoradiation Therapy?, E. Yu, A. R. Dar, R. Ash, G. Videtic, P. Truong, L. Stitt, A. Tomiak, M. Vincent, R. Malthaner, I. Craig, E. Brecevic, W. Kocha, R. Inculet, M. Lefcoe
Is Extended Volume Of External Beam Irradiation Beneficial In Post-Esophagectomy High Risk Patients Receiving Combined Chemoradiation Therapy?, E. Yu, A. R. Dar, R. Ash, G. Videtic, P. Truong, L. Stitt, A. Tomiak, M. Vincent, R. Malthaner, I. Craig, E. Brecevic, W. Kocha, R. Inculet, M. Lefcoe
Oncology Presentations
OBJECTIVE: To assess the value of extended volume irradiation with anastomotic coverage in high risk resected esophageal cancer patients.
METHOD: A retrospective study was undertaken at LRCC from 1989-1999 for high risk resected esophageal cancer patients. Adjuvant treatments consisted of 4 cycles of chemotherapy (epirubicin/fluorouracil/cisplatin or cisplatin/fluorouracil), and local regional irradiation with or without coverage of the anastomotic site. Radiation dose ranged from 45-60Gy at 1.8-2.0 Gy/fraction given with initial anterior-posterior/posterior-anterior arrangement with either extended (with anastomotic coverage) or small (without anastomotic coverage) field followed by oblique fields for boost.
RESULT: One hundred eighty-eight charts were reviewed. Seventy-two patients were …