Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Biomedical Engineering and Bioengineering

Development And Validation Of Mechatronic Systems For Image-Guided Needle Interventions And Point-Of-Care Breast Cancer Screening With Ultrasound (2d And 3d) And Positron Emission Mammography, Claire Ks Park May 2023

Development And Validation Of Mechatronic Systems For Image-Guided Needle Interventions And Point-Of-Care Breast Cancer Screening With Ultrasound (2d And 3d) And Positron Emission Mammography, Claire Ks Park

Electronic Thesis and Dissertation Repository

The successful intervention of breast cancer relies on effective early detection and definitive diagnosis. While conventional screening mammography has substantially reduced breast cancer-related mortalities, substantial challenges persist in women with dense breasts. Additionally, complex interrelated risk factors and healthcare disparities contribute to breast cancer-related inequities, which restrict accessibility, impose cost constraints, and reduce inclusivity to high-quality healthcare. These limitations predominantly stem from the inadequate sensitivity and clinical utility of currently available approaches in increased-risk populations, including those with dense breasts, underserved and vulnerable populations.

This PhD dissertation aims to describe the development and validation of alternative, cost-effective, robust, and high-resolution …


Improving The Reliability And Accessibility Of Ct Perfusion Imaging In Acute Ischemic Stroke, Kevin J. Chung Feb 2023

Improving The Reliability And Accessibility Of Ct Perfusion Imaging In Acute Ischemic Stroke, Kevin J. Chung

Electronic Thesis and Dissertation Repository

CT perfusion (CTP) imaging is a validated treatment decision support tool in acute ischemic stroke. Automated analysis of CTP cerebral blood flow (CBF) and Tmax maps produces estimates of ischemic core and penumbra volumes used to determine target mismatch profiles for treatment. However, availability and utilization of CTP is low due to diagnostic variability between CTP software and technical, logistical, and radiation dose considerations that may limit its routine adoption. The objective of this doctoral research was to improve the reliability and accessibility of CTP by (1) improving diagnostic agreement between CTP software, (2) enabling perfusion imaging with standard acute …


A Two-Layer Continuous-Capillary Oxygen Transport Model: Development And Application To Blood Flow Regulation In Resting Skeletal Muscle., Keith C. Afas Aug 2022

A Two-Layer Continuous-Capillary Oxygen Transport Model: Development And Application To Blood Flow Regulation In Resting Skeletal Muscle., Keith C. Afas

Electronic Thesis and Dissertation Repository

In skeletal muscle (SM), the microcirculation distributes blood flow to capillary networks to meet local oxygen (O2) demand. Experiments using intra-vital video microscopy (IVVM) have quantified blood flow and O2 supply in capillary networks, and using an O2 exchange chamber have measured local changes in blood flow believed due to O2-dependent regulation. However, IVVM is unable to simultaneously measure capillary O2 supply and SM O2 content, implying the need for theoretical models to understand how flow regulation and SM oxygenation interact. In this thesis, a novel blood-tissue O2 transport model using …


Cost-Effective Non-Destructive Testing Of Biomedical Components Fabricated Using Additive Manufacturing, Santiago Fabian Cobos Mar 2022

Cost-Effective Non-Destructive Testing Of Biomedical Components Fabricated Using Additive Manufacturing, Santiago Fabian Cobos

Electronic Thesis and Dissertation Repository

Biocompatible titanium-alloys can be used to fabricate patient-specific medical components using additive manufacturing (AM). These novel components have the potential to improve clinical outcomes in various medical scenarios. However, AM introduces stability and repeatability concerns, which are potential roadblocks for its widespread use in the medical sector. Micro-CT imaging for non-destructive testing (NDT) is an effective solution for post-manufacturing quality control of these components. Unfortunately, current micro-CT NDT scanners require expensive infrastructure and hardware, which translates into prohibitively expensive routine NDT. Furthermore, the limited dynamic-range of these scanners can cause severe image artifacts that may compromise the diagnostic value of …


Frequency Dependent Diffusion Kurtosis Measurement In The Human Brain With Oscillating Gradients, Kevin B. Borsos Aug 2021

Frequency Dependent Diffusion Kurtosis Measurement In The Human Brain With Oscillating Gradients, Kevin B. Borsos

Electronic Thesis and Dissertation Repository

Oscillating gradient spin-echo (OGSE) is an implementation of diffusion MRI that enables shorter effective diffusion times than the conventional pulse gradient spin-echo (PGSE) by periodically modulating the diffusion gradient. Measurements of the diffusion kurtosis, which reflects the degree of restricted diffusion, have previously been prohibited with OGSE due to technical limitations of clinical gradient systems. This thesis presents a novel oscillating gradient waveform that enables the measurement of kurtosis using OGSE without requiring advanced gradient hardware. Decreases of kurtosis are observed in OGSE acquisitions of healthy human subjects relative to PGSE, demonstrating the dependence of the kurtosis on oscillation frequency. …


The Design, Fabrication, And Characterization Of Nanoparticle-Protein Interactions For Theranostic Applications, Wai Hei Tse Aug 2017

The Design, Fabrication, And Characterization Of Nanoparticle-Protein Interactions For Theranostic Applications, Wai Hei Tse

Electronic Thesis and Dissertation Repository

Theranostics, a combination of therapeutics and diagnostics, spans a spectrum of research areas to provide new opportunities in developing new healthcare technologies and medicine at affordable prices. Through employing a personalized medicine approach, biotechnology can be tailored to the needs of an individual. Applications of theranostics include drug delivery carriers capable of sustained drug release and targeted delivery, biosensors with high sensitivity and selectivity, and diagnostic relevant entities that can be incorporated into the former technologies. Nanotechnology provides a suitable foundation for theranostics to build upon due to material-based properties; magnetism, biocompatibility, and quantum effects to name a few. Purpose …


Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon Apr 2016

Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon

Electronic Thesis and Dissertation Repository

The purpose of this collection of studies was to further develop the knowledge of shoulder motion in order to better understand joint function through direct measurement of 3D scapulohumeral joint kinematics using a technique of high accuracy. Markerless, bi-planar fluoroscopic radiostereometric analysis using a generic shoulder model was developed in this thesis, reducing the amount of radiation exposure to subjects. The studies compared kinematic data of the scapulohumeral joint in six degrees of freedom with a precise, in-vivo measuring technique. Data were collected on young and older healthy individuals, individuals with a torn supraspinatus and post-surgical intervention.

Although this generic …


The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …


Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall May 2012

Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall

Electronic Thesis and Dissertation Repository

The hybridization of magnetic resonance imaging (MRI) with positron emission tomography (PET) or single photon emission computed tomography (SPECT) enables the collection of an assortment of biological data in spatial and temporal register. However, both PET and SPECT are subject to photon attenuation, a process that degrades image quality and precludes quantification. To correct for the effects of attenuation, the spatial distribution of linear attenuation coefficients (μ-coefficients) within and about the patient must be available. Unfortunately, extracting μ-coefficients from MRI is non-trivial. In this thesis, I explore the problem of MRI-based attenuation correction (AC) in emission tomography.

In particular, I …


Modeling Lung Tissue Motions And Deformations: Applications In Tumor Ablative Procedures, Ali Sadeghi Naini May 2011

Modeling Lung Tissue Motions And Deformations: Applications In Tumor Ablative Procedures, Ali Sadeghi Naini

Electronic Thesis and Dissertation Repository

Various types of motion and deformation that the lung undergoes during minimally invasive tumor ablative procedures have been investigated and modeled in this dissertation. The lung frequently undergoes continuous large respiratory deformation, which can greatly affect the pre-planned outcome of the operation, hence deformation compensation becomes necessary. The first type of major deformation involved in a target lung throughout a tumor ablative procedure is the one encountered in procedures where the lung is totally deflated before starting the operation. A consequence of this deflation is that pre-operative images (acquired while the lung was partially inflated) become inaccurate for targeting the …