Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering

Virginia Commonwealth University

Mechanical Engineering

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Biomedical Engineering and Bioengineering

Patient-Specific Analysis Of Aortic Hemodynamics And Wall Shear Stresses In Patients Undergoing Pediatric Bariatric Surgery Using 2d Phase-Contrast Mri, Oluwaferanmi S. Akande, Joao Soares, Nathan Hargan, Dr. Uyen Truong, Haeung Kang, David Lanning Jan 2023

Patient-Specific Analysis Of Aortic Hemodynamics And Wall Shear Stresses In Patients Undergoing Pediatric Bariatric Surgery Using 2d Phase-Contrast Mri, Oluwaferanmi S. Akande, Joao Soares, Nathan Hargan, Dr. Uyen Truong, Haeung Kang, David Lanning

Undergraduate Research Posters

Patient-Specific Analysis of Aortic Hemodynamics and Wall Shear Stresses in Patients Undergoing Pediatric Bariatric Surgery using 2D Phase-Contrast MRI

Feranmi Akande1 Nathan Hargan2 Haesung Kang3 David Lanning3 Uyen Truong4 João S. Soares1

1 Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University

2 Department of Mechanical & Nuclear Engineering, College of Engineering, Virginia Commonwealth University

3 Department of Cardiology, Children’s Hospital of Richmond, Virginia Commonwealth University

Introduction: Severe obesity among today’s youth is a rising epidemic within the United States. Emerging research has linked childhood obesity with shortened life expectancy and early …


Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee Jan 2017

Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee

Undergraduate Research Posters

The ECGs I micro-fabricate are designed to be flexible, stretchable and wireless circuits that can be applied to the skin directly. The device is encased in a conformal, silicon-like substrate, that allows the ECG to be attached with the electrodes. Each electrode has been previously measured and verified that it will be correctly placed for an accurate reading. Prototyping this ECG/electrode device allows the user to mount the prototype directly to the patient without having to attach and wire ten other electrodes. This prototype solves the issue that comes about when a doctor, nurse or emergency medical technician must attach …