Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering

Old Dominion University

Theses/Dissertations

Tactile sensor

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Biomedical Engineering and Bioengineering

Estimation Of Arterial Wall Parameters Via Model-Based Analysis Of Noninvasively Measured Arterial Pulse Signals, Dan Wang Apr 2019

Estimation Of Arterial Wall Parameters Via Model-Based Analysis Of Noninvasively Measured Arterial Pulse Signals, Dan Wang

Mechanical & Aerospace Engineering Theses & Dissertations

This dissertation presents a model-based method for estimating arterial wall parameters from noninvasively measured arterial pulse signals via a microfluidic-based tactile sensor. The sensor entails a polydimethylsiloxane (PDMS) microstructure embedded with 5×1 transducer array built on Pyrex/Polyethylene terephthalate (PET) substrate. The arterial pulse causes a time-varying deflection on the top of the PDMS microstructure, which registers as a resistance change by the transducer at the site of the artery.

Owing to the time-harmonic nature of its radial motion, the arterial wall is modeled as a second-order dynamic system. By combining this dynamic model with a hemodynamic model of blood flow, …


Understanding The Mechanical Behavior Of Costal Cartilage At Their Curved Exterior Surface Via A Tactile Sensor With A Built-In Probe For Distributed-Deflection Detection, Jiayue Shen Apr 2018

Understanding The Mechanical Behavior Of Costal Cartilage At Their Curved Exterior Surface Via A Tactile Sensor With A Built-In Probe For Distributed-Deflection Detection, Jiayue Shen

Mechanical & Aerospace Engineering Theses & Dissertations

This dissertation is aimed to determine the mechanical properties at the exterior surface of costal cartilages (CC) and examine how they vary with the cartilage length and the anatomical sites of CC in the ribcage via conformal indentation testing which is built upon a tactile sensor for distributed-deflection detection. The sensor entails a rectangular Polydimethylsiloxane (PDMS) microstructure sensing-plate integrated with a 5 ×1 transducer array with 0.75mm spatial resolution underneath and a built-in probe of 0.5mm×5mm×3mm above. By pressing the sensor against the exterior surface of a CC tissue with a pre-defined indentation pattern, the sensor conforms to the curved …