An Experimentally Validated Computational Model For The Degradation And Fracture Of Magnesium-Based Implants In A Chemically Corrosive Environment, Mark M. Ousdigian Jan 2023

An Experimentally Validated Computational Model For The Degradation And Fracture Of Magnesium-Based Implants In A Chemically Corrosive Environment, Mark M. Ousdigian

Dissertations, Master's Theses and Master's Reports

In the orthopedic and cardiovascular fields there is a growing interest for biodegradable implants, which can be naturally degraded in the body environment over time so that no extraction surgery is required. These implants must be designed to maintain their strength until the fracture has healed in the body, which could be influenced by many factors such as -the patient’s age, activities, body weight, pre-existing conditions etc. Hence, an ideal implant design should be done on a patient-by-patient basis. In the present work, a computational model is developed to predict the degradation and fracture of magnesium-based implants in a stress-coupled …


3d Printing Of Iron Oxide Incorporated Polydimethylsiloxane Soft Magnetic Actuator, Rasoul Bayaniahangar Jan 2020

3d Printing Of Iron Oxide Incorporated Polydimethylsiloxane Soft Magnetic Actuator, Rasoul Bayaniahangar

Dissertations, Master's Theses and Master's Reports

Soft actuators have grown to be a topic of great scientific interest recently. As the fabrication of soft actuators with conventional microfabrication methods are tedious, expensive, and time consuming, employment of 3-D printing fabrication methods appears promising as they can simplify fabrication and reduce the production cost. Complex structures can be fabricated with 3-D printing such as helical coils can achieve actuation performances that otherwise would not be possible with simpler geometries. In this thesis development of soft magnetic helical coil actuators of iron-oxide embedded polydimethylsiloxane (PDMS) was achieved with embedded 3-D printing techniques. Composites with three different weight ratios …


3d Printing In Low Resource Healthcare Settings: Analysis Of Potential Implementations, Alenna Beroza Jan 2019

3d Printing In Low Resource Healthcare Settings: Analysis Of Potential Implementations, Alenna Beroza

Dissertations, Master's Theses and Master's Reports

3D printing has gained significant momentum in the past ten years, and its unique advantages make it especially ideal for use in low resource healthcare settings, where many designs have already been successfully implemented. Yet, little has been studied on how 3D printing can be sustainably and functionally implemented in low resource healthcare systems as a manufacturing practice. In this report, three business models are proposed for this implementation: In-House Operator, Independent Operator, and Print Farm. These models were then tested over four months in Kisumu county, Kenya, at two workshops and seven public hospitals. I worked with local medical …


Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop Jan 2019

Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop

Dissertations, Master's Theses and Master's Reports

The purpose of this research is to investigate the relationship between the mechanical impedance of the human ankle and the corresponding lower extremity muscle activity. Three experimental studies were performed to measure the ankle impedance about multiple degrees of freedom (DOF), while the ankle was subjected to different loading conditions and different levels of muscle activity. The first study determined the non-loaded ankle impedance in the sagittal, frontal, and transverse anatomical planes while the ankle was suspended above the ground. The subjects actively co-contracted their agonist and antagonistic muscles to various levels, measured using electromyography (EMG). An Artificial Neural Network …


A Hybrid-Powered Wireless System For Multiple Biopotential Monitoring, Shawn Li Jan 2019

A Hybrid-Powered Wireless System For Multiple Biopotential Monitoring, Shawn Li

Dissertations, Master's Theses and Master's Reports

Chronic diseases are the top cause of human death in the United States and worldwide. A huge amount of healthcare costs is spent on chronic diseases every year. The high medical cost on these chronic diseases facilitates the transformation from in-hospital to out-of-hospital healthcare. The out-of-hospital scenarios require comfortability and mobility along with quality healthcare. Wearable electronics for well-being management provide good solutions for out-of-hospital healthcare. Long-term health monitoring is a practical and effective way in healthcare to prevent and diagnose chronic diseases. Wearable devices for long-term biopotential monitoring are impressive trends for out-of-hospital health monitoring. The biopotential signals in …


Estimation And Prediction Of The Human Gait Dynamics For The Control Of An Ankle-Foot Prosthesis, Guilherme Aramizo Ribeiro Jan 2019

Estimation And Prediction Of The Human Gait Dynamics For The Control Of An Ankle-Foot Prosthesis, Guilherme Aramizo Ribeiro

Dissertations, Master's Theses and Master's Reports

With the growing population of amputees, powered prostheses can be a solution to improve the quality of life for many people. Powered ankle-foot prostheses can be made to behave similar to the lost limb via controllers that emulate the mechanical impedance of the human ankle. Therefore, the understanding of human ankle dynamics is of major significance. First, this work reports the modulation of the mechanical impedance via two mechanisms: the co-contraction of the calf muscles and a change of mean ankle torque and angle. Then, the mechanical impedance of the ankle was determined, for the first time, as a multivariable …


Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak Jan 2017

Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak

Dissertations, Master's Theses and Master's Reports

Football helmets have been used for many years to prevent head injuries to players. Over the years, the helmet design has evolved from a crude leather head covering to the more recent form fitting helmets that are seen today. The one design feature that has been common in the majority of all helmets is a hard polycarbonate shell with a foam cushion padding. The main goal of the padding layer was to reduce the amount of linear acceleration during an impact event. The one feature that has been overlooked is how stiff the padding is in rotation.

The purpose of …


Mechanical Impedance Of Ankle As A Function Of Electromyography Signals Of Lower Leg Muscles Using Artificial Neural Network, Chen Jia Jan 2015

Mechanical Impedance Of Ankle As A Function Of Electromyography Signals Of Lower Leg Muscles Using Artificial Neural Network, Chen Jia

Dissertations, Master's Theses and Master's Reports - Open

This paper reports on the feasibility of developing a model to describe the nonlinear relationship between the mechanical impedance of the human ankle within a specified range of frequency and the root mean square (RMS) value of the Electromyography (EMG) signals of the muscles of human ankle using Artificial Neural Network (ANN). A lower extremity rehabilitation robot — Anklebot was used to apply pseudo-random mechanical perturbations to the ankle and measure the angular displacement of the ankle to estimate the data of ankle mechanical impedance. Meanwhile, the surface EMG signals from the selected muscles were monitored and recorded using a …


A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari Jan 2014

A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari

Dissertations, Master's Theses and Master's Reports - Open

Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based …