Compensation For Inertial And Gravity Effects In A Moving Force Platform, Sandra K. Hnat, Ben J.H. Van Basten, Antonie J. Van Den Bogert Jun 2018

Compensation For Inertial And Gravity Effects In A Moving Force Platform, Sandra K. Hnat, Ben J.H. Van Basten, Antonie J. Van Den Bogert

Mechanical Engineering Faculty Publications

Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled surface movements, or in conditions where the foundation is moving or not sufficiently rigid. Here we present a linear model to predict the inertial and gravitational artifacts using accelerometer signals. The model is first calibrated with data collected from random movements of the unloaded system and then used to compensate for the errors in …


Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo Nov 2010

Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo

Mechanical Engineering Faculty Publications

In this paper, a personal micronavigation system that uses high-resolution gait-corrected inertial measurement units is presented. The goal of this paper is to develop a navigation system that uses secondary inertial variables, such as velocity, to enable long-term precise navigation in the absence of Global Positioning System (GPS) and beacon signals. In this scheme, measured zerovelocity duration from the ground reaction sensors is used to reset the accumulated integration errors from accelerometers and gyroscopes in position calculation. With the described system, an average position error of 4 m is achieved at the end of half-hour walks.


An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin Jan 2010

An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin

Mechanical Engineering Faculty Publications

Background

Currently, natural and synthetic scaffolds are being explored as augmentation devices for rotator cuff repair. When used in this manner, these devices are believed to offer some degree of load sharing; however, no studies have quantified this effect. Furthermore, the manner in which loads on an augmented rotator cuff repair are distributed among the various components of the repair is not known, nor is the relative biomechanical importance of each component. The objectives of this study are to (1) develop quasi-static analytical models of simplified rotator cuff repairs, (2) validate the models, and (3) predict the degree of load …


A Real-Time, 3-D Musculoskeletal Model For Dynamic Simulation Of Arm Movements, Edward K. Chadwick, Dimitra Blana, Antonie J. Van Den Bogert, Robert F. Kirsch Apr 2009

A Real-Time, 3-D Musculoskeletal Model For Dynamic Simulation Of Arm Movements, Edward K. Chadwick, Dimitra Blana, Antonie J. Van Den Bogert, Robert F. Kirsch

Mechanical Engineering Faculty Publications

Neuroprostheses can be used to restore movement of the upper limb in individuals with high-level spinal cord injury. Development and evaluation of command and control schemes for such devices typically require real-time, ldquopatient-in-the-looprdquo experimentation. A real-time, 3-D, musculoskeletal model of the upper limb has been developed for use in a simulation environment to allow such testing to be carried out noninvasively. The model provides real-time feedback of human arm dynamics that can be displayed to the user in a virtual reality environment. The model has a 3-DOF glenohumeral joint as well as elbow flexion/extension and pronation/supination and contains 22 muscles …


Comment On "Quadriceps Protects The Anterior Cruciate Ligament", Antonie J. Van Den Bogert Sep 2002

Comment On "Quadriceps Protects The Anterior Cruciate Ligament", Antonie J. Van Den Bogert

Mechanical Engineering Faculty Publications

No abstract provided.