Open Access. Powered by Scholars. Published by Universities.®
![Digital Commons Network](http://assets.bepress.com/20200205/img/dcn/DCsunburst.png)
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Antennas (1)
- Arthroscopic (1)
- Assistive device (1)
- Bragg gratings (1)
- Catheter navigation (1)
-
- Design (1)
- Embedded systems (1)
- Fiber optic (1)
- Fluoroscopy (1)
- Force sensing (1)
- Hand tremor (1)
- IMU (1)
- Image-guidance (1)
- Low-cost (1)
- MRI Engineering (1)
- MRI Hardware (1)
- Magnetic Resonance Imaging (1)
- Magnetic resonance imaging (1)
- Master-slave (1)
- Microwave Electronics (1)
- Minimally-invasive surgery (1)
- Motion sensing (1)
- Parkinson's Disease (1)
- Parkinson's disease (1)
- Pathological tremor (1)
- Piezoelectric (1)
- Radio-Frequency Arrays (1)
- Radio-Frequency Engineering (1)
- Radiofrequency ablation (1)
- Robust control (1)
Articles 1 - 6 of 6
Full-Text Articles in Biomedical Engineering and Bioengineering
Modelling And Evaluation Of Piezoelectric Actuators For Wearable Neck Rehabilitation Devices, Shaemus D. Tracey
Modelling And Evaluation Of Piezoelectric Actuators For Wearable Neck Rehabilitation Devices, Shaemus D. Tracey
Electronic Thesis and Dissertation Repository
Neck pain is the most common neck musculoskeletal disorder, and the fourth leading cause of healthy years lost due to disability in the world. Due to the need of hands-on physical therapy and Canada’s aging population, access to treatment will become highly constrained. Wearable devices that allow at-home rehabilitation address this future limitation. However, few have emerged from the laboratory setting because they are limited by the use of conventional actuators. An overlooked type of actuation technology is that of piezoelectric actuators, more specifically, travelling wave ultrasonic motors (TWUM).
In this work, a clear procedure that outlines how the required …
The Development Of A Motion Sensing Device For Use In A Home Setting, Jaspreet K. Kalsi
The Development Of A Motion Sensing Device For Use In A Home Setting, Jaspreet K. Kalsi
Electronic Thesis and Dissertation Repository
Parkinson's disease (PD) is the second most prevalent neurodegenerative disease, with over 10 million individuals diagnosed with PD world-wide. The most common symptom characterized by PD is tremor. Tremor is an involuntary oscillatory motion that most prominently occurs in upper limb, specifically in the hand and wrist that has a measurable frequency and amplitude. This thesis aims to evaluate the usability and functionality of a tremor sensing device designed to collect quantitative data on individuals with PD. The designed device uses 23 commercially-available inertial measuring units (IMUs) located between 21 joints: distal interphalangeal (DIP) joints, proximal interphalangeal (PIP) joints, Interphalangeal …
A Wearable Mechatronic Device For Hand Tremor Monitoring And Suppression: Development And Evaluation, Yue Zhou
A Wearable Mechatronic Device For Hand Tremor Monitoring And Suppression: Development And Evaluation, Yue Zhou
Electronic Thesis and Dissertation Repository
Tremor, one of the most disabling symptoms of Parkinson's disease (PD), significantly affects the quality of life of the individuals who suffer from it. These people live with difficulties with fine motor tasks, such as eating and writing, and suffer from social embarrassment. Traditional medicines are often ineffective, and surgery is highly invasive and risky. The emergence of wearable technology facilitates an externally worn mechatronic tremor suppression device as a potential alternative approach for tremor management. However, no device has been developed for the suppression of finger tremor that has been validated on a human.
It has been reported in …
Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell
Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell
Electronic Thesis and Dissertation Repository
Magnetic Resonance Imaging (MRI) is an indispensable, non-invasive diagnostic tool for the assessment of disease and function. As an investigational device, MRI has found routine use in both basic science research and medicine for both human and non-human subjects.
Due to the potential increase in spatial resolution, signal-to-noise ratio (SNR), and the ability to exploit novel tissue contrasts, the main magnetic field strength of human MRI scanners has steadily increased since inception. Beginning in the early 1980’s, 0.15 T human MRI scanners have steadily risen in main magnetic field strength with ultra-high field (UHF) 8 T MRI systems deemed to …
Magnetic Resonance Imaging Compatible Remote Catheter Navigation System, Mohammad Ali Tavallaei
Magnetic Resonance Imaging Compatible Remote Catheter Navigation System, Mohammad Ali Tavallaei
Electronic Thesis and Dissertation Repository
Many vascular and cardiac diseases are diagnosed and treated using a medical technique known as percutaneous transluminal catheter intervention (PTC). In PTC, the interventionalist inserts a catheter into the vasculature, and using the vessel as the guiding passageway, the catheter is navigated to desired anatomical targets where it would be used for various purposes such as catheter ablation for the treatment/management of cardiac arrhythmias. The catheterization procedure is conventionally guided with x-ray fluoroscopic imaging and more recently, but rarely, with Magnetic Resonance Imaging (MRI). X-ray imaging irradiates the patient directly during the procedure, and the staff and interventionalists indirectly through …
Force Sensing In Arthroscopic Instruments Using Fiber Bragg Gratings, Daniel S. Yurkewich
Force Sensing In Arthroscopic Instruments Using Fiber Bragg Gratings, Daniel S. Yurkewich
Electronic Thesis and Dissertation Repository
Minimally-invasive surgery has revolutionized many medical procedures; however, it also impedes the ability to feel the interaction between the surgical tool and the anatomical part being operated on. In order to address this problem, it is necessary to obtain accurate measurements of the interaction forces exerted on the surgical tools during surgery. These forces can then be manifested to the surgeon via a haptic device or presented visually (visual-force feedback). This thesis describes the use of a fiber optic device to measure and display to the surgeon interaction forces acting on an arthroscopic tool. The sensorization of the tool involves …