Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Devices and Instrumentation

Accelerometer

Series

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


Accelerometer Based Measurement For The Mapping Of Neck Surface Vibrations During Vocalized Speech, Mark Nolan, Brian Madden, Edward Burke Sep 2009

Accelerometer Based Measurement For The Mapping Of Neck Surface Vibrations During Vocalized Speech, Mark Nolan, Brian Madden, Edward Burke

Conference Papers

This paper presents a detailed study of the vibrations on the surface of the neck during a vocalization of predefined fundamental frequency and intensity. This study was carried out as part of a wider investigation into the use of laryngeal vibrations as a channel of communication. Another potential application of this study is in identifying a suitable location for a hands-free electro-larynx for laryngectomees.

An analog accelerometer, with dimensions 5x5x1.6mm and of mass 80mg, was used to perform the measurements. It was connected to a 12-bit analog-to-digital converter via single strands of insulated wire with a diameter of 100μm. The …


Accelerometer Based Measurement Of Body Movement For Communication, Play, And Creative Expression, Mark Nolan, Edward Burke, Frank Duignan Nov 2008

Accelerometer Based Measurement Of Body Movement For Communication, Play, And Creative Expression, Mark Nolan, Edward Burke, Frank Duignan

Conference Papers

This paper presents a newly designed wireless accelerometer-based movement measurement device. The device is capable of measuring activity ranging from gross body movements to more subtle vibrations emanating from the body, including laryngeal vibration and the mechanomyogram (mechanical vibrations from working muscles). The main body of the device, which is less than 20cm3 in volume and weighs less than 50g, contains a microcontroller, wireless transceiver, battery, and one accelerometer. A supplementary accelerometer module is connected to the main device by thin wires. This module is very light weight and can therefore be directly attached to the skin to measure laryngeal …