Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
Articles 1 - 4 of 4
Full-Text Articles in Biomedical Engineering and Bioengineering
Full-Field Vibrometry By High-Speed Digital Holography For Middle-Ear Mechanics, Ivo Dobrev
Full-Field Vibrometry By High-Speed Digital Holography For Middle-Ear Mechanics, Ivo Dobrev
Ivo Dobrev
Hearing loss affects approximately 1 in 10 people in the world and this percentage is increasing every year. Some of the most common courses for hearing loss are disorders of the human tympanic membrane (TM or eardrum) and middle-ear. Early detection and diagnosis of hearing loss as well as research and understanding of the hearing process depend on medical and research tools for quantification of the hearing capabilities, including the function of the human TM in the complex acoustic-mechanical transformation of environmental sounds into vibrations of the middle- and the inner-ear. Current ear exams are assessing the state of the …
Vicon Motion System, Arezoo Eshraghi
Sparse Signal Reconstruction From Polychromatic X-Ray Ct Measurements Via Mass Attenuation Discretization, Renliang Gu, Aleksandar Dogandžić
Sparse Signal Reconstruction From Polychromatic X-Ray Ct Measurements Via Mass Attenuation Discretization, Renliang Gu, Aleksandar Dogandžić
Aleksandar Dogandžić
We propose a method for reconstructing sparse images from polychromatic x-ray computed tomography (ct) measurements via mass attenuation coefficient discretization. The material of the inspected object and the incident spectrum are assumed to be unknown. We rewrite the Lambert-Beer’s law in terms of integral expressions of mass attenuation and discretize the resulting integrals. We then present a penalized constrained least-squares optimization approach forreconstructing the underlying object from log-domain measurements, where an active set approach is employed to estimate incident energy density parameters and the nonnegativity and sparsity of the image density map are imposed using negative-energy and smooth ℓ1-norm penalty …
Xena: An Automated 'Open-Source' 129xe Hyperpolarizer For Clinical Use, Panayiotis Nikolaou, Aaron M. Coffey, Laura L. Walkup, Brogan M. Gust, Nicholas Whiting, Hayley Newton, Iga Muradyan, Mikayel Dabaghyan, Kaili Ranta, Gregory D. Moroz, Matthew S. Rosen, Samuel Patz, Michael J. Barlow, Eduard Y. Chekmenev, Boyd M. Goodson
Xena: An Automated 'Open-Source' 129xe Hyperpolarizer For Clinical Use, Panayiotis Nikolaou, Aaron M. Coffey, Laura L. Walkup, Brogan M. Gust, Nicholas Whiting, Hayley Newton, Iga Muradyan, Mikayel Dabaghyan, Kaili Ranta, Gregory D. Moroz, Matthew S. Rosen, Samuel Patz, Michael J. Barlow, Eduard Y. Chekmenev, Boyd M. Goodson
Nicholas Whiting