Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Devices and Instrumentation

Electronic Theses and Dissertations

Theses/Dissertations

Mechanical and Materials Engineering

Publication Year

Articles 1 - 5 of 5

Full-Text Articles in Biomedical Engineering and Bioengineering

Hemodynamic Assessment Of Y-Incision Aortic Root Enlargement Using Computational Simulations, Astitwa Ghimire Aug 2023

Hemodynamic Assessment Of Y-Incision Aortic Root Enlargement Using Computational Simulations, Astitwa Ghimire

Electronic Theses and Dissertations

The Yang procedure is a new aortic root enlargement technique used to enlarge the aortic annulus by multiple valve sizes. The procedure prevents patient prosthesis mismatch and establishes a viable platform for future valve-in-valve implantation. This study used the Yang procedure to investigate the hemodynamics in the aortic root and bioprosthetic valve regions after aortic root enlargement. Results indicate the velocity magnitude at the sinus regions of a patient who underwent the Yang procedure was slower, indicating risks of flow stasis and thrombosis. Simulation results denote computational models can be created for optimization of surgical procedures.


Fully Coupled Fluid Structure Interaction Simulation Of Bioprosthetic Heart Valves: A Numerical And Experimental Analysis, Masod Sadipour Jun 2023

Fully Coupled Fluid Structure Interaction Simulation Of Bioprosthetic Heart Valves: A Numerical And Experimental Analysis, Masod Sadipour

Electronic Theses and Dissertations

Aortic stenosis impacts approximately 7% of the global population. In the past decade, the role of computational modeling has been becoming considerably important in the design of BHVs. To obtain reliable solutions in computational modeling, it is essential to consider accurate properties of bioprosthetic heart valves (BHVs), such as density and mechanical properties. Previous computational studies assumed (bovine pericardium) BP used in BHVs density was comparable to water or blood. Yet, BP is subjected to multiple treatments like fixation and anti-calcification. In Chapter 2, I measured BP density and its effect on BHV leaflet stress and strain. In the second …


Patient Movement Monitoring Based On Imu And Deep Learning, Mohsen Sharifi Renani Jun 2023

Patient Movement Monitoring Based On Imu And Deep Learning, Mohsen Sharifi Renani

Electronic Theses and Dissertations

Osteoarthritis (OA) is the leading cause of disability among the aging population in the United States and is frequently treated by replacing deteriorated joints with metal and plastic components. Developing better quantitative measures of movement quality to track patients longitudinally in their own homes would enable personalized treatment plans and hasten the advancement of promising new interventions. Wearable sensors and machine learning used to quantify patient movement could revolutionize the diagnosis and treatment of movement disorders. The purpose of this dissertation was to overcome technical challenges associated with the use of wearable sensors, specifically Inertial Measurement Units (IMUs), as a …


Contact Simulation For Evaluating Patient Specific Surgical Guide Stability, Vincent Nierste Jan 2022

Contact Simulation For Evaluating Patient Specific Surgical Guide Stability, Vincent Nierste

Electronic Theses and Dissertations

This study proposes a novel computational method to quantify guide stability for Patient Specific Instrumentation (PSI) guides. A finite element contact model was used to analyze the final position of PSI guides on a femur across a range of loading parameters representing forces applied by a surgeon during operative use. Separate segmentation methods were used for the guide and bone geometry to represent differences between segmentation and actual patient geometry. The region of loading parameters over which the guide exhibited a consistent final position was measured and reported as Guide Stability Score. The model was verified using cadaver specimens for …


Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi Jan 2020

Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi

Electronic Theses and Dissertations

Transcatheter mitral valve replacement (TMVR) is being developed to become a substitute therapy for surgery in prohibitive or high surgical risk patients to treat severe mitral regurgitation. A limited number of TMVR systems are under clinical evaluation. However, transcatheter mitral valve (TMV) long-term durability and hemodynamic performance is not known. TMV durability and hemodynamics must match with that of surgical bioprostheses for potential commercialization of TMVR. Experimental and computational approaches were used to find the leaflets’ three-dimensional anisotropic mechanical properties in a transcatheter Edwards SAPIEN 3 valve and a surgical Carpentier-Edwards PERIMOUNT Magna mitral valve and finite element (FE) simulations …