Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 12 of 12

Full-Text Articles in Biomedical Engineering and Bioengineering

Design Of A Portable Fast Scan Cyclic Voltammetry Device Utilizing Pulse Width Modulation For Waveform Generation, Nora Szymkowski Aug 2024

Design Of A Portable Fast Scan Cyclic Voltammetry Device Utilizing Pulse Width Modulation For Waveform Generation, Nora Szymkowski

Masters Theses

Fast Scan Cyclic Voltammetry (FSCV) is a widely used electrochemical technique for real-time measurement of the brain’s chemical messengers, including the molecule dopamine, with high temporal resolution. Currently the financial burden of performing FSCV is quite high, ranging from $8,000 to $20,000+ making the barrier to entry nearly insurmountable for laboratories and classrooms at small institutions. The purpose of this project was to develop a Do-It-Yourself (DIY), portable, and cost-effective FSCV system for use in laboratory and classroom settings. The project aimed to create a compact and cost-effective system that could be used by researchers and educators to study dopamine …


Potential Impact Of Proposed Medical Device On Hospital Acquired Anemia, Sam Menzie May 2024

Potential Impact Of Proposed Medical Device On Hospital Acquired Anemia, Sam Menzie

Masters Theses

Evacuated tubes are the industry standard for drawing blood and have improved phlebotomist and patient safety as well as paved the way for laboratory automation. Current practices using evacuated tubes do not allow caregivers to control the volume of blood drawn, leading to blood waste in hospital settings. This overdrawing of blood has led to the prevalence of iatrogenic anemia, or hospital acquired anemia (HAA). HAA represents a significant risk to patients, leading to increased adverse conditions, and a higher consumption of hospital resources. This study seeks to model the efficacy of a potential new medical device. The proposed device …


Effect Of Amputation On Muscle Structure Properties In A Rabbit Model, Roy Caleb Stubbs May 2023

Effect Of Amputation On Muscle Structure Properties In A Rabbit Model, Roy Caleb Stubbs

Masters Theses

After amputation, muscles in the residual limb are detached from their insertion points and no longer span the missing joints. Our objective was to quantify the effect of amputation-induced disuse on residual muscle structure, an indirect indicator of muscle force-generating capacity. One hind paw was surgically removed at the ankle joint of ten rabbits. At two weeks (n=5) and 4 weeks (n=5) post-amputation and for select muscles (gastrocnemius, soleus, tibialis cranialis, extensor digitorum, and flexor digitorum superficialis), we measured and computed several muscle structure properties. Additionally, we qualitatively assessed the muscle fiber appearance of histological samples at each timepoint. At …


Camera-Based Remote Photoplethysmography For Estimation Of Heart Rate Using Single Board Computers, Benjamin Sweely Dec 2020

Camera-Based Remote Photoplethysmography For Estimation Of Heart Rate Using Single Board Computers, Benjamin Sweely

Masters Theses

The objective of this project was to develop a wireless, noncontact monitoring system that measures multiple physiological parameters in human faces from a distance using a camera. Compared to traditional sensors, this monitoring system does not use wires or adhesives, providing a safer, more user-friendly application. The goal of the monitoring systems was to estimate heart rate (HR). The current practices of measuring HR involve collecting electrocardiogram (ECG) signals from adhesive electrodes placed on various parts of the body and using a pulse oximeter (PO) typically placed on the ear lobe or finger. We were able to successfully create 2 …


The Design And Development Of A Device To Assist In Boosting Patients, Taylor A. Rieckhoff Dec 2019

The Design And Development Of A Device To Assist In Boosting Patients, Taylor A. Rieckhoff

Masters Theses

A common task a nurse is required to perform is called boosting patients. Boosting a patient is defined as lifting or sliding a patient back up in the bed after having slid down (Mannheim, Zieve, & Conaway, 2017). The current method for boosting patients involves a minimum of two personnel and an 11-step process. The 11-step process requires the person to manually lift and pull the patient using an existing half sheet on the bed (Mannheim, Zieve, & Conaway, 2017). Patients who cannot move or support themselves are moved every two to six hours or upon request (Bihn, Rieckhoff, Burkman, …


Design Of A Robotic Instrument Manipulator For Endoscopic Deployment, Ryan Ponten Aug 2017

Design Of A Robotic Instrument Manipulator For Endoscopic Deployment, Ryan Ponten

Masters Theses

This thesis describes the initial design process for an application of continuum robotics to endoscopic surgical procedures, specifically dissection of the colon. We first introduce the long-term vision for a benchtop dual-instrument endoscopic system with intuitive haptic controllers and then narrow our focus to the design and testing of the instrument manipulator itself, which must be actuated through the long, winding channel of a standard colonoscope.

Based on design requirements for a target procedure, we analyze simulations of two types of continuum robots using recently established kinematic and mechanic modeling approaches: the concentric-tube robot (CTR) and the concentric agonist-antagonist robot …


A Feasibility Study Of Just-In-Time Asthma Self-Management Intervention, Phillip Charles Scruggs Aug 2016

A Feasibility Study Of Just-In-Time Asthma Self-Management Intervention, Phillip Charles Scruggs

Masters Theses

Quality asthma care requires not only an initial diagnosis, but long term follow up care and education on long term control. Preventable symptoms continue to reduce the quality of life for chronic asthma sufferers and place an unnecessary burden on emergency services and the health care system at large. A mobile health (mHealth) solution is proposed to effectively improve outcomes for patients while ultimately reducing the overall burden of mismanagement on the healthcare system as a whole. The Just-in-Time Asthma Self- Management and Intervention (JASMIN) system provides a way for a patient or user to track, self-manage, and interact with …


Icloudecg: A Mobile Cardiac Telemedicine System, David S. Clifford Dec 2015

Icloudecg: A Mobile Cardiac Telemedicine System, David S. Clifford

Masters Theses

With rising healthcare costs and a substantially growing number of patients 65 or over, the benefits of telemedicine and patient self-monitoring systems are becoming increasingly evident. Patients, physicians, hospitals, and even insurance providers benefit from vigilant, cost-effective patient monitoring systems. This thesis describes the development of a portable, smart-phone connected system for continuous cardiac monitoring. The system is capable of continuously monitoring the conditions of the heart, automated detection of cardiac arrhythmias, and real-time notifying patients and physicians of the detected abnormalities. The system consists of four main subsystems: 1) a Bluetooth capable chest-strap ECG, 2) an Android-enabled mobile device, …


Doping Of Fluorchlorozirconate And Borate-Silica Glass Ceramics For Medical Imaging And Fast Neutron Scintillation, Julie Elizabeth Swafford May 2015

Doping Of Fluorchlorozirconate And Borate-Silica Glass Ceramics For Medical Imaging And Fast Neutron Scintillation, Julie Elizabeth Swafford

Masters Theses

Borate silica glass ceramics were produced for neutron scintillation. The Glass ceramics were doped with europium fluoride [EuF2] and cerium chloride [CeCl3]. Isotopic lithium fluoride [6LiF] and boron oxide [10B2O3] were used in most samples while non-isotopic lithium fluoride [LiF] and boron oxide [ B2O3] were used in the rest. When exposed to a neutron beam, samples doped with europium fluoride [EuF2] scintillated while samples doped with cerium chloride [CeCl3] did not. This contradicts current literature on fast scintillation. What …


A Low-Power Approach For Front End Biological Signal Conditioning, Logan Smith Taylor Dec 2014

A Low-Power Approach For Front End Biological Signal Conditioning, Logan Smith Taylor

Masters Theses

In a lab-on-a-chip (LOC) application, the measurement of small analog signals such as local temperature variation often involves detection of very low-level signals in a noisy micro-scale environment. This is true for other biomedical monitoring systems as well. These systems observe various physiological parameters or electrochemical reactions that need to be tracked electrically. For temperature measurement pyroelectric transducers represent an efficient solution in terms of speed, sensitivity, and scale of integration, especially when prompt and accurate temperature monitoring is desired.

The ability to perform laboratory operations on a small scale using miniaturized LOC devices is a promising biosensing technique. The …


An Implantable Low Pressure Biosensor Transponder, Chad Eric Seaver Dec 2013

An Implantable Low Pressure Biosensor Transponder, Chad Eric Seaver

Masters Theses

The human body’s intracranial pressure (ICP) is a critical element in sustaining healthy blood flow to the brain while allowing adequate volume for brain tissue within the relatively rigid structure of the cranium. Disruptions in the body’s maintenance of intracranial pressure are often caused by hemorrhage, tumors, edema, or excess cerebral spinal fluid resulting in treatments that are estimated to globally cost up to approximately five billion dollars annually. A critical element in the contemporary management of acute head injury, intracranial hemorrhage, stroke, or other conditions resulting in intracranial hypertension, is the real-time monitoring of ICP. Currently such monitoring can …


Optimization Of Insertion Holes And Anchor Design For Cylinder Shaped Toggle Type Suture Anchors, Adam Fedenia Jan 1999

Optimization Of Insertion Holes And Anchor Design For Cylinder Shaped Toggle Type Suture Anchors, Adam Fedenia

Masters Theses

This research was performed to optimize insertion holes and anchor design for cylinder shaped toggle type suture anchors. Four types of anchors were investigated in terms of pull strength and design in acrylic plate and pig bone. They included small type A and B anchors and large type A and B anchors.

Pull strength trends suggest that the small type anchors behave similarly since their external dimensions are identical, with the exception of type A anchor having a hole running from one end of the cylinder to the other like a pipe. It was found that the suture would fail …