Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 3 of 3
Full-Text Articles in Biomedical Engineering and Bioengineering
Computational Bone Mechanics Modeling With Frequency Dependent Rheological Properties And Crosslinking, Timothy G. Moreno
Computational Bone Mechanics Modeling With Frequency Dependent Rheological Properties And Crosslinking, Timothy G. Moreno
Master's Theses
Bone is a largely bipartite viscoelastic composite. Its mechanical behavior is determined by strain rate and the relative proportions of its principal constituent elements, hydroxyapatite and collagen, but is also largely dictated by their geometry and topology. Collagen fibrils include many segments of tropocollagen in staggered, parallel sequences. The physical staggering of this tropocollagen allows for gaps known as hole-zones, which serve as nucleation points for apatite mineral. The distance between adjacent repeat units of tropocollagen is known as D-Spacing and can be measured by Atomic Force Microscopy (AFM). This D-Spacing can vary in length slightly within a bundle, but …
Optimal Parameter Values For Accurate And Repeatable Nanoindentation Of Human Trabecular Bone, Stephen Matthew Kmak
Optimal Parameter Values For Accurate And Repeatable Nanoindentation Of Human Trabecular Bone, Stephen Matthew Kmak
Master's Theses
Nanoindentation techniques have not been standardized for use on bone tissues, making comparison of bone material properties obtained via nanoindentation across studies difficult and unreliable. This study determined a set of optimal parameter values for thermal drift correction time, dwell time, and loading rate that can be used to obtain accurate and repeatable material properties from human femoral trabecular bone through experimentation and statistical analysis. All testing was conducted using a single nanoindenter on a single trabeculae, with the assumption that material properties within the individual trabeculae were internally consistent. Parameters not of interest during this study, such as ambient …
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Master's Theses
With more young adults requiring total hip
arthroplasties the need for bone saving implants becomes
more important. The Zimmer Fitmore is a new bone saving
implant that utilizes an implantation technique that
reduces the damage to the muscle tissue allowing for
patients to have a short recovery time as well as a new
design that allows it to rest on the medial cortex. There
has been anecdotal evidence that this device leads to early
revision within six months of implantation due to failures
occurring in the medial cortex. The main goal of this
study was to computationally model the Zimmer …