Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Molecular Dynamics Investigation Of The Arabinan-Cellulose Interface For Cellulose Nanocomposite Applications, Luke Thornley Jun 2015

Molecular Dynamics Investigation Of The Arabinan-Cellulose Interface For Cellulose Nanocomposite Applications, Luke Thornley

Materials Engineering

Atom level computer simulations of the arabinan and cellulose interface were performed to better understand the mechanisms that give arabinan-cellulose composites (ArCCs) their strength with the goal to improve man-made ArCCs. The molecular dynamics (MD) software LAMMPS was used in conjunction with the ReaxFF/c force field to model the bond between cellulose and arabinan. A cellulose nanocrystal with dimensions 51 x 32 x 8 Å was minimized with various weight percent of water, 0%, 3%, 5%, 8%, 10%, and 12%. After the system was equilibrated for at least 100,000 femtoseconds, an arabinan molecule composed of 8 arabinose rings was added …


Renal Artery Stent Fatigue Test, Braden Cooper, Munir Eltal, Jennifer Hawthorne, Ashley Schaefer Jun 2015

Renal Artery Stent Fatigue Test, Braden Cooper, Munir Eltal, Jennifer Hawthorne, Ashley Schaefer

Mechanical Engineering

In today’s world of medical innovation, regulations and requirements set by organizations such as the Food and Drug Administration (FDA), the International Organization for Standardization (ISO), and ASTM International (American Society for Testing and Materials) can inhibit rapid innovation by demanding rigorous testing of new designs. For arterial stents, the standard is that each design must be tested to simulate 10 years of life in an environment congruent to an in vivo environment. Endologix in Irvine, California develops and manufactures minimally invasive treatments for aortic diseases, with a focus on stent grafts for the treatment of abdominal aortic aneurysms (AAA). …


Self-Contained Breathing Apparatus For Firefighter With A Permanent Stoma, Jason Delgadillo, Aaron Wheeler, Zachary Wishbow Jun 2015

Self-Contained Breathing Apparatus For Firefighter With A Permanent Stoma, Jason Delgadillo, Aaron Wheeler, Zachary Wishbow

Biomedical Engineering

The purpose of this project was to create a unique SCBA (self-contained breathing apparatus) for a firefighter named Chris Gauer. This prototype consists of a SCBA headgear connected to a polycarbonate-formed stoma mask with a medical-grade sanitary silicone hose.