Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 2 of 2
Full-Text Articles in Biomedical Engineering and Bioengineering
Objectively Measuring Effects Of Electro-Acupuncture In Parkinsonian Rhesus Monkeys, Rui Zhang, Anders H. Andersen, Peter A. Hardy, Eric Forman, April Evans, Yi Ai, Jin Yue, Guihua Yue, Don M. Gash, Richard Grondin, Zhiming Zhang
Objectively Measuring Effects Of Electro-Acupuncture In Parkinsonian Rhesus Monkeys, Rui Zhang, Anders H. Andersen, Peter A. Hardy, Eric Forman, April Evans, Yi Ai, Jin Yue, Guihua Yue, Don M. Gash, Richard Grondin, Zhiming Zhang
Magnetic Resonance Imaging and Spectroscopy Center Faculty Publications
Acupuncture has increasingly been used as an alternative therapy for treatment of Parkinson’s disease (PD). However, the efficacy of acupunture for PD still remains unclear. The present study was designed to objectively and safely monitor anti-parkinsonian effects of electroacupuncture (EA) and brain activity in nonhuman primates modeling human PD. Six middle-aged rhesus monkeys were extensively studied by a computerized behavioral testing battery and by pharmacological MRI (phMRI) scans with specific dopaminergic drug stimulations. All animals were evaluated for behavior and phMRI responses under normal, parkinsonian, parkinsonian with EA treatment and parkinsonian after EA treatment conditions. Stable parkinsonian features were observed …
High Resolution Imaging Of The Mitral Valve In The Natural State With 7 Tesla Mri, Sam E. Stephens, Serguei Liachenko, Neil B. Ingels, Jonathan F. Wenk, Morten O. Jensen
High Resolution Imaging Of The Mitral Valve In The Natural State With 7 Tesla Mri, Sam E. Stephens, Serguei Liachenko, Neil B. Ingels, Jonathan F. Wenk, Morten O. Jensen
Mechanical Engineering Faculty Publications
Imaging techniques of the mitral valve have improved tremendously during the last decade, but challenges persist. The delicate changes in annulus shape and papillary muscle position throughout the cardiac cycle have significant impact on the stress distribution in the leaflets and chords, thus preservation of anatomically accurate positioning is critical. The aim of this study was to develop an in vitro method and apparatus for obtaining high-resolution 3D MRI images of porcine mitral valves in both the diastolic and systolic configurations with physiologically appropriate annular shape, papillary muscle positions and orientations, specific to the heart from which the valve was …