Open Access. Powered by Scholars. Published by Universities.®
![Digital Commons Network](http://assets.bepress.com/20200205/img/dcn/DCsunburst.png)
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
- Publication
- Publication Type
Articles 1 - 2 of 2
Full-Text Articles in Biomedical Engineering and Bioengineering
Frontal White Matter Integrity In Adults With Down Syndrome With And Without Dementia, David K. Powell, Allison Caban-Holt, Greg A. Jicha, William C. Robertson, Roberta Davis, Brian T. Gold, Frederick A. Schmitt, Elizabeth Head
Frontal White Matter Integrity In Adults With Down Syndrome With And Without Dementia, David K. Powell, Allison Caban-Holt, Greg A. Jicha, William C. Robertson, Roberta Davis, Brian T. Gold, Frederick A. Schmitt, Elizabeth Head
Magnetic Resonance Imaging and Spectroscopy Center Faculty Publications
Adults with Down syndrome (DS) are at high risk for developing Alzheimer's disease after the age of 40 years. To detect white matter (WM) changes in the brain linked to dementia, fractional anisotropy (FA) from diffusion tensor imaging was used. We hypothesized that adults with DS without dementia (DS n = 10), DS with dementia (DSAD n = 10) and age matched non-DS subjects (CTL n = 10) would show differential levels of FA and an association with scores from the Brief Praxis Test and the Severe Impairment Battery. WM integrity differences in DS compared with CTL were found predominantly …
Stabilization Of Extended Diffuse Optical Spectroscopy Measurements On In Vivo Human Skeletal Muscle During Dynamic Exercise, Brad A. Henry
Stabilization Of Extended Diffuse Optical Spectroscopy Measurements On In Vivo Human Skeletal Muscle During Dynamic Exercise, Brad A. Henry
Theses and Dissertations--Biomedical Engineering
This research investigates various applications of diffuse correlation spectroscopy (DCS) on in-vivo human muscle tissue, both at rest and during dynamic exercise. Previously suspected muscle tissue relative blood flow (rBF) baseline shift during extended measurement with DCS and DCS-Near infrared spectroscopy (NIRS) hybrid optical systems are verified, quantified, and resolved by redesign of optical probe and alteration in optical probe attachment methodology during 40 minute supine bed rest baseline measurements. We then translate previously developed occlusion techniques, whereby rBF and relative oxygen consumption rV̇O2 are calibrated to initial resting absolute values by use of a venous occlusion (VO) and …