Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Engineering

Light Scattering In Diffraction Limit Infrared Imaging, Ghazal Azarfar Aug 2019

Light Scattering In Diffraction Limit Infrared Imaging, Ghazal Azarfar

Theses and Dissertations

Fourier Transform Infrared (FTIR) microspectroscopy is a noninvasive technique for chemical imaging of micrometer size samples. Employing an infrared microscope, an infrared source and FTIR spectrometer coupled to a microscope with an array of detectors (128 x 128 detectors), enables collecting combined spectral and spatial information simultaneously. Wavelength dependent images are collected, that reveal biochemical signatures of disease pathology and cell cycle. Single cell biochemistry can be evaluated with this technique, since the wavelength of light is comparable to the size of the objects of interest, which leads to additional spectral and spatial effects disturb biological signatures and can confound …


Multi-Tap Extended Kalman Filter For A Periodic Waveform With Uncertain Frequency And Waveform Shape, And Data Dropouts, Justin Saboury Aug 2019

Multi-Tap Extended Kalman Filter For A Periodic Waveform With Uncertain Frequency And Waveform Shape, And Data Dropouts, Justin Saboury

Theses and Dissertations

Gait analysis presents the challenge of detecting a periodic waveform in the presence of time varying frequency, amplitude, DC offset, and waveform shape, with acquisition gaps from partial occlusions. The combination of all of these components presents a formidable challenge. The Extended Kalman Filter for this system model has six states, which makes it weakly identifiable within the standard Extended Kalman Filter network. In this work, a novel robust Extended Kalman Filter-based approach is presented and evaluated for clinical use in gait analysis. The novel aspect of the proposed method is that at each sample, the present and several past …


Piezoelectric Sensor Crack Detection On Airframe Systems, Kevin J. Lin Mar 2019

Piezoelectric Sensor Crack Detection On Airframe Systems, Kevin J. Lin

Theses and Dissertations

In 2008, the Department of Defense published a guidebook for a methodology named Condition-Based Maintenance Plus (CBM+) which capabilities include improving productivity, shortening maintenance cycles, lowering costs, and increasing availability and reliability. This push replaces existing inspection criteria, often conducted as non-destructive testing (NDT), with structural health monitoring (SHM) systems. The SHM system addressed utilizes guided Lamb waves generated by piezoelectric wafer active sensors (PWAS) to detect the existence, size, and location of damage from through-thickness cracks around a rivet hole. The SHM field lacks an experiment testing how small changes in receiver sensor distances affect damage detection. In addition, …


Wall Model Large Eddy Simulation Of A Diffusing Serpentine Inlet Duct, Ryan J. Thompson Mar 2019

Wall Model Large Eddy Simulation Of A Diffusing Serpentine Inlet Duct, Ryan J. Thompson

Theses and Dissertations

The modeling focus on serpentine inlet ducts (S-duct), as with any inlet, is to quantify the total pressure recovery and ow distortion after the inlet, which directly impacts the performance of a turbine engine fed by the inlet. Accurate prediction of S-duct ow has yet to be achieved amongst the computational fluid dynamics (CFD) community to improve the reliance on modeling reducing costly testing. While direct numerical simulation of the turbulent ow in an S-duct is too cost prohibitive due to grid scaling with Reynolds number, wall-modeled large eddy simulation (WM-LES) serves as a tractable alternative. US3D, a hypersonic research …


Schlieren Imaging And Flow Analysis On A Cone/Flare Model In The Afrl Mach 6 Ludwieg Tube Facility, David A. Labuda Mar 2019

Schlieren Imaging And Flow Analysis On A Cone/Flare Model In The Afrl Mach 6 Ludwieg Tube Facility, David A. Labuda

Theses and Dissertations

High-speed Schlieren photography was utilized to visualize flow in the Air Force Research Laboratory Mach 6 Ludwieg tube facility. A 7° half-angle cone/flare model with variable nosetip radius and flare angle options was used in the study. Testing was performed at two driver tube pressures, generating freestream Reynolds numbers of 10.0x106 and 19.8x106 per meter. The variable-angle flare portion of the model provided a method for adjusting the intensity of the adverse pressure gradient at the cone/flare junction. As expected from existing literature, boundary layer separation along the cone frustum occurred further upstream as the magnitude of the …