Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Engineering

A Coupled Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Wire Waveguide, Graham Gavin, Finbar Dolan, M.S. Hashmi, Garrett Mcguinness Dec 2007

A Coupled Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Wire Waveguide, Graham Gavin, Finbar Dolan, M.S. Hashmi, Garrett Mcguinness

Articles

Ultrasonic longitudinal displacements, delivered to the distal tips of small diameter wire waveguides, have been shown to be capable of disrupting complicated atherosclerotic plaques during vascular interventions. These ultrasonic displacements can disrupt plaques by direct contact ablation but also by pressure waves, associated cavitation and acoustic streaming developed in the surrounding blood and tissue cavities. The pressure waves developed within the arterial lumen appear to play a major role but are complex to predict as they are determined by the distal tip output of the wire waveguide (both displacement and frequency), the geometric features of the waveguide tip and the …


Comparison Of Stent Designs Using Computational Fluid Dynamics, Jonathan Murphy, Fergal Boyle Mar 2007

Comparison Of Stent Designs Using Computational Fluid Dynamics, Jonathan Murphy, Fergal Boyle

Conference Papers

Coronary artery disease (CAD) is one of the leading causes of death in the developed world. CAD occurs due to the build up of plaque in the coronary arteries which supply fresh blood to the constantly active heart muscle. Several methods exist to alleviate CAD such as coronary artery bypass grafting, balloon angioplasty and coronary stenting. A coronary stent is a small tubular prosthesis which can improve blood flow by acting as a scaffold to prop the diseased artery open. However, stent restenosis (re-blockage) remains a common problem with different stent designs leading to different restenosis rates. This work investigates …


Performance Characteristics Of A Therapeutic Ultrasound Wire Waveguide, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. Hashmi Mar 2007

Performance Characteristics Of A Therapeutic Ultrasound Wire Waveguide, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. Hashmi

Articles

Therapeutic ultrasound angioplasty has been investigated, clinically, by a number of researchers and represents a potentially promising therapy for the treatment of atherosclerotic lesions. To date, there has been no detailed analysis of the effect of mechanical design parameters, such as wire geometry or damping characteristics, on wire waveguide performance. An apparatus capable of delivering therapeutic ultrasound down small diameter nickel–titanium (NiTi) wire waveguides is described. The output peak-to-peak (p–p) displacements at the distal tip of a 1.0mm diameter waveguide were measured experimentally, by means of an optical microscope and image analysis software. The output was measured for a range …


Application Of Advanced Computational Modelling In The Comparison Of Stent Induced Coronary Flow Disturbances, Jonathan Murphy, Fergal Boyle Feb 2007

Application Of Advanced Computational Modelling In The Comparison Of Stent Induced Coronary Flow Disturbances, Jonathan Murphy, Fergal Boyle

Conference Papers

Coronary stent implantation can improve blood flow in an artery narrowed by the build up of arterial plaque. However, the haemodynamic effect of stent placement is unclear and may influence arterial restenosis (re-blockage). In this investigation computational fluid dynamics (CFD) was used to predict the non-Newtonian three-dimensional flow field in a coronary artery following implantation of two different stents. A graphical illustration of the stented areas affected to various degrees of wall shear stress (WSS) is presented for both the Palmaz-Schatz (PS) and the Gianturco-Roubin-II (GR-II) coronary stents. The axial WSS and wall shear stress gradient (WSSG) is also presented …


Evaluation Of Stent Design Based On The Haemodynamic Effect Of Coronary Stenting, Jonathan Murphy, Fergal Boyle Jan 2007

Evaluation Of Stent Design Based On The Haemodynamic Effect Of Coronary Stenting, Jonathan Murphy, Fergal Boyle

Conference Papers

No abstract provided.


Transfer Function Modelling: A Student-Centred Learning Approach, Aidan O'Dwyer Jan 2007

Transfer Function Modelling: A Student-Centred Learning Approach, Aidan O'Dwyer

Conference papers

Traditionally, the modelling of real systems in engineering, using transfer functions, has been done in a mathematically intense manner. However, non-traditional learners such as mature students, part-time students and students without a conventional second-level educational background may not have strong mathematical foundations; in addition, all students increasingly expect technical work which is practical and which motivates independent learning. This paper reports on, reflects on and evaluates an innovative experiment developed by the author to estimate a transfer function model of a person’s eye-brain-hand motor response. In the experiment, carried out using a PC with data acquisition capability, the person is …


Medical Rehabilitation Robotics, David Kennedy, Philip Deering, James Conlon Jan 2007

Medical Rehabilitation Robotics, David Kennedy, Philip Deering, James Conlon

Conference Papers

Robotic Rehabilitation is a novel field of bio engineering combining precise mechanical design with control technology through the interaction of Medical and Engineering professionals to produce a new tool in medical rehabilitation. Paralysis is one of the common symptoms of a stroke sufferer; a medical condition causing weakness in one side of the body. It is treatable with a course of physiotherapy and Interactive Robotics can greatly accelerate this recovery. Although Robotic Rehabilitation is a relatively new technology its benefits are well recognized. The objective of this research work was to develop an interactive robot for the medical rehabilitation of …