Emisja Metali Ciężkich Ze Spalania Odpadów Niebezpiecznych, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1997

Emisja Metali Ciężkich Ze Spalania Odpadów Niebezpiecznych, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of air emissions of heavy metals from hazardous waste incineration in a multiple hearth furnace and a rotary kiln incinerator equipped with a single wet flue gas cleaning systems. In the multiple hearth furnace an industrial sewage sludge (from coke industry) was being incinerated. In the rotary kiln such wastes were being incinerated as: waste paints, varnish and lubricant, coal tars waste, contaminated cleaning rags, sawdust and used gloves, waste resins and plastics, rubber waste, outdated pharmaceuticals and medicines, and hospital waste. The research allowed us to determine the levels of pollutant concentrations …


Zastosowanie Modelu "Skrzynki" Do Oceny Poziomu Stężeń Zanieczyszczeń Komunikacyjnych W Przyziemnej Warstwie Atmosfery, Marek Bogacki, Marian Mazur, Robert Oleniacz Dec 1997

Zastosowanie Modelu "Skrzynki" Do Oceny Poziomu Stężeń Zanieczyszczeń Komunikacyjnych W Przyziemnej Warstwie Atmosfery, Marek Bogacki, Marian Mazur, Robert Oleniacz

Robert Oleniacz

Road transport is an essential source of nitrogen oxides (NOx), carbon monoxide (CO) and reactive hydrocarbons (RHC) emissions to atmosphere. Quantity and chemical constitution of emitted substances and meteorological conditions determine the level of ozon (O3) concentration forming as a result of photochemical reactions. The method presented in the paper consists in designation of quantity and chemical constitution of substances emitted from mo-bile sources and special mathematical modeling of physical and chemical transformations that take place in the lowest atmospheric layer.

English title: The use of box model to estimate the size of traffic pollutant concentrations in the lowest atmospheric …


Emisja Zanieczyszczeń Podczas Składowania I Termicznej Utylizacji Osadów Ściekowych Z Przemysłu Koksochemicznego / Emissions During Storage And Thermal Utilization Of Sewage Sludge From Coke-Chemical Industry, Robert Oleniacz, Marian Mazur, Marek Bogacki Sep 1997

Emisja Zanieczyszczeń Podczas Składowania I Termicznej Utylizacji Osadów Ściekowych Z Przemysłu Koksochemicznego / Emissions During Storage And Thermal Utilization Of Sewage Sludge From Coke-Chemical Industry, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

Both storage and thermal disposal of sewage sludge from industrial wastewater treatment plants are a significant source of air pollutant emissions. The study included the sludge generated in the coke-chemical industry. The paper presents the results of measurements of emissions of selected substances during storage of the waste in a closed storage hall with natural ventilation and during incineration of the mechanically dewatered sludge in a multiple hearth furnace.


Spalanie Odpadów Poszpitalnych I Farmaceutycznych W Piecu Obrotowym / Incineration Of Hospital And Pharmaceutical Wastes In A Rotary Kiln Incinerator, Robert Oleniacz, Marian Mazur, Marek Bogacki Sep 1997

Spalanie Odpadów Poszpitalnych I Farmaceutycznych W Piecu Obrotowym / Incineration Of Hospital And Pharmaceutical Wastes In A Rotary Kiln Incinerator, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The paper presents selected results of research on hospital and pharmaceutical waste incineration in a full-scale rotary kiln with variable loads of the kiln. As part of these studies measurements of air pollutant concentrations in flue gases and leaching tests of solid combustion products were carried out. Based on these studies, the maximum dose of hospital and pharmaceutical waste was proposed in the mixture with industrial wastes, which does not cause excessive air emissions. The average emission factors for the waste mixture loading were also determined.


Koncepcja Monitoringu Zanieczyszczeń Powietrza Wokół Elektrowni “Jaworzno Iii” Mobilną Stacją Pomiarową, Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz Jun 1997

Koncepcja Monitoringu Zanieczyszczeń Powietrza Wokół Elektrowni “Jaworzno Iii” Mobilną Stacją Pomiarową, Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz

Robert Oleniacz

The paper presents the concept of air pollution monitoring around the Power Plant "Jaworzno III" (Poland) with the use of the mobile station. Aim of the new monitoring system is to provide information about the current state of air pollution and to enable an assessment of the environmental implications of the use of low-emission burners, run the installation of flue gas desulphurisation and changes in the way of releasing flue gases into the atmosphere. Due to economic, technical and practical the monitoring system was based on a single mobile station. Measurements will be carried out in a random scheme at …


Spalarnia Odpadów Lobbe W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Ryszard Januszek Apr 1997

Spalarnia Odpadów Lobbe W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Ryszard Januszek

Robert Oleniacz

This paper is a general characteristic of the industrial and hazardous waste incineration plant which was operated in Dąbrowa Górnicza (Poland) in the 90. The waste incineration plant is based on two incinerators - a rotary kiln and a multiple hearth furnace. Levels of selected air pollutant emissions presented in the work allow to assess the potential impact of this facility on air quality.

English title: The LOBBE incineration plant in Dąbrowa Górnicza.