Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Engineering

Understanding The Surface Fouling Mechanism Of Ultrananocrystalline Diamond Microelectrodes Using Microfluidics For Neurochemical Detection, An-Yi Chang Jul 2017

Understanding The Surface Fouling Mechanism Of Ultrananocrystalline Diamond Microelectrodes Using Microfluidics For Neurochemical Detection, An-Yi Chang

Doctoral Dissertations

Electrochemical methods are widely used for chronic neurochemical sensing, but thus far, the organic solution redox reactions fouled the electrodes' surface. It caused the reduction of sensitivity and the electrodes' lifetime.

Here, we present the boron-doped nanocrystalline diamond microelectrodes (BDUNCD) as the next generation electrode material for neurochemical sensor development. To aid in long-term chronic monitoring of neurochemicals, they have a wide window of electrochemical potential, extremely low background current, and excellent chemical inertness. The main research goal is to reduce the rate of electrode fouling due to the reaction by-products, and significantly extend their useful lifetime.

We systematically characterize …


Electrochemical Behavior Of Dense Electrodes For Impedancemetric Nox Sensors, Nabamita Pal Jul 2017

Electrochemical Behavior Of Dense Electrodes For Impedancemetric Nox Sensors, Nabamita Pal

Doctoral Dissertations

NOx (NO and NO2) exhaust gas sensors for diesel powered vehicles have traditionally consisted of porous platinum (Pt) electrodes along with a dense ZrO2 based electrolyte. Advancement in diesel engine technology results in lower NOx emissions. Although Pt is chemically and mechanically tolerant to the extreme exhaust gas environment, it is also a strong catalyst for oxygen reduction, which can interfere with the detection of NOx at concentrations below 100 ppm. Countering this behavior can add to the complexity and cost of the conventional NO x sensor design. Recent studies have shown that dense electrodes are less prone to heterogeneous …


Full Simulation For The Qweak Experiment At 1.16 And 0.877 Gev And Their Impact On Extracting The Pv Asymmetry In The N→Δ A Transition, Hend Abdullah Nuhait Jul 2017

Full Simulation For The Qweak Experiment At 1.16 And 0.877 Gev And Their Impact On Extracting The Pv Asymmetry In The N→Δ A Transition, Hend Abdullah Nuhait

Doctoral Dissertations

The Qweak project is seeking to find new physics beyond the Standard Model. It is aimed to measure the weak charge of the proton, which has never been measured, at 4% precision at low momentum transfer. The experiment is performed by scattering electrons from protons and exploiting parity violation in the weak interaction at low four-momentum transfer.

In this experiment, two measurements were considered: which are elastic and inelastic. The elastic is to measure the proton's weak charge. In addition, the inelastic asymmetry measurement, which will extract the low energy constant dΔ. That measurement works in the neutral current …


Stretching The Limits Of Dynamic Range, Shielding Effectiveness, And Multiband Frequency Response, Matthew J. Hartmann Jul 2017

Stretching The Limits Of Dynamic Range, Shielding Effectiveness, And Multiband Frequency Response, Matthew J. Hartmann

Doctoral Dissertations

In this dissertation, an RF MEMS variable capacitor suitable for applications requiring ultrawide capacitive tuning ranges is reported. The device uses an electrostatically tunable liquid dielectric interface to continuously vary the capacitance without the use of any moving parts. As compared to existing MEMS varactors in literature, this device has an extremely simple design that can be implemented using simple fabrication methods that do not necessitate the use of clean room equipment. In addition, this varactor is particularly suited for incorporating a wide range of liquid dielectric materials for specific tuning ratio requirements.

Additionally, the shielding effectiveness performance of graphene-doped …


Improvement Of Fluorescence-Based Microfluidic Dna Analyzers, Collin Tranter Apr 2017

Improvement Of Fluorescence-Based Microfluidic Dna Analyzers, Collin Tranter

Doctoral Dissertations

A tremendous effort continues in the development of micro-total-analysis-systems; in support of this, many chemical passivation methods have been developed to enhance the biocompatibility of such microfluidic systems. However, the suitability of these passivation techniques to many fluorescence-based assays still remains inconsistent. This part of this work is focused on the performance of a third generation intercalating DNA dye when used within microfluidic devices treated with a select variety of passivating coatings. The results of these tests indicate that passivation coatings which are intended to shed DNA based on electrostatic repulsion will in fact imbibe the fluorescent DNA intercalating dye …


Development Of A Nonlinear Model For The Prediction Of Response Times Of Glucose Affinity Sensors Using Concanavalin A And Dextran And The Development Of A Differential Osmotic Glucose Affinity Sensor, Louis G. Reis Jan 2017

Development Of A Nonlinear Model For The Prediction Of Response Times Of Glucose Affinity Sensors Using Concanavalin A And Dextran And The Development Of A Differential Osmotic Glucose Affinity Sensor, Louis G. Reis

Doctoral Dissertations

With the increasing prevalence of diabetes in the United States and worldwide, blood glucose monitoring must be accurate and reliable. Current enzymatic sensors have numerous disadvantages that make them unreliable and unfavorable among patients. Recent research in glucose affinity sensors correct some of the problems that enzymatic sensors experience. Dextran and concanavalin A are two of the more common components used in glucose affinity sensors. When these sensors were first explored, a model was derived to predict the response time of a glucose affinity sensor using concanavalin A and dextran. However, the model assumed the system was linear and fell …


Synthesis, Characterization, And Activity Of Co/Fe Alumina/Silica Supported Ft Catalysts And The Study Of Promoter Effect Of Ruthenium, Sunday Azubike Esumike Jan 2017

Synthesis, Characterization, And Activity Of Co/Fe Alumina/Silica Supported Ft Catalysts And The Study Of Promoter Effect Of Ruthenium, Sunday Azubike Esumike

Doctoral Dissertations

The alumina and hybrid alumina-silica FT catalyst were prepared by one-step solgel/oil-drop methods using metal-nitrate-solutions (method-I), and nanoparticle-metaloxides (method-2). The nanoparticle-metal-oxides did not participate in solubility equilibria in contrast to metal nitrate in method-1 causing no metal ion seepage; therefore, method-2 yields higher XRF metal loading efficiency than method-1. The thermal analysis confirmed that the metal loading by method-1 and method-2 involved two different pathways. Method-1 involves solubility equilibria in the conversion of metal-nitrate to metal- hydroxide and finally to metal-oxide, while in method-2 nanoparticle-metal-oxide remained intact during sol-gel-oil-drop and calcination steps.

The alumina supported catalysts were dominated by γ-alumina …


A Study Of Mathematics Achievement, Placement, And Graduation Of Engineering Students, Sara Hahler Blazek Jan 2017

A Study Of Mathematics Achievement, Placement, And Graduation Of Engineering Students, Sara Hahler Blazek

Doctoral Dissertations

The purpose of this study was to determine how background knowledge impacts freshmen engineering students' success at Louisiana Tech University in terms of grades in two different freshman classes and graduation. To determine what factors impact students, three different studies were implemented. The first study used linear regression to analyze which demographic and academic variables significantly impacted freshman math and engineering courses. Using regression discontinuity, the second study determined if the university's placement requirement for Pre-Calculus was appropriate. The final study analyzed factors that impact graduation for engineering students as well as other disciplines to determine which significant variables were …


Design, Modeling, Fabrication, And Testing Of A Multistage Micro Gas Compressor With Piezoelectric Unimorph Diaphragm And Passive Microvalves For Microcooling Applications, Shawn Thanhson Le Jan 2017

Design, Modeling, Fabrication, And Testing Of A Multistage Micro Gas Compressor With Piezoelectric Unimorph Diaphragm And Passive Microvalves For Microcooling Applications, Shawn Thanhson Le

Doctoral Dissertations

This dissertation investigates the development of a multistage micro gas compressor utilizing multiple pump stages cascaded in series to increase the pressure rise with passive microvalves and piezoelectric unimorph diaphragms. This research was conducted through modeling, simulation, design, and fabrication of the microcompressor and its components. A single-stage and a two-stage microcompressor were developed to demonstrate and compare the performance and effectiveness of using a cascaded multistage design.

Steady fluid flow through static microvalves structure was studied to gain insight on its gas flow dynamics and characteristics. Transient analysis combined with the structure's interaction was investigated with an analytical model …


Expanding The Applications Of Poly(Dimethylsiloxane) In Biomicrofluidics, Sawyer D. Stone Jan 2017

Expanding The Applications Of Poly(Dimethylsiloxane) In Biomicrofluidics, Sawyer D. Stone

Doctoral Dissertations

This work aims to create novel applications for poly(dimethylsiloxane) (PDMS) in the field of biomicrofluidics through oxidative stress detection, doping of the polymer for intentional leaching into microdevices, and the development of low-cost implements for fabricating PDMS microfluidic devices. PDMS has become the polymer of choice for research in microfluidics due to its optical clarity, ease of fabrication, flexibility in design, good mechanical properties, and the ability to chemically modify the surface.

Biomicrofluidics enables the rapid throughput and analysis of small biological samples requiring less time investment and reagent use than traditional macroscale laboratory techniques. Polymer devices are inexpensive, easily …