Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 30 of 77

Full-Text Articles in Engineering

Development Of An In Vitro 3-Dimensional Co-Culture Human Colorectal Cancer Model In Microfluidic Devices, Abby Jens Mar 2024

Development Of An In Vitro 3-Dimensional Co-Culture Human Colorectal Cancer Model In Microfluidic Devices, Abby Jens

Master's Theses

Colorectal cancer is the second most common cause of cancer-related deaths in the United States, with the relative 5-year survival rate for distant stage cancer being only 14%. The most common treatment for colorectal cancer is with chemotherapeutic drugs; however, the discovery of these drugs is costly, time-consuming, and often requires the use of animal models that do not yield results that translate to clinical trials. Due to these shortcomings, researchers seek to develop physiologically relevant in vitro tumor models that more accurately mimic the tumor microenvironment for cheaper and faster high-throughput drug screening. The aim of this research was …


Finite Element Analysis Of The Bearing Component Of Total Ankle Replacement Implants During The Stance Phase Of Gait, Timothy S. Jain Mar 2024

Finite Element Analysis Of The Bearing Component Of Total Ankle Replacement Implants During The Stance Phase Of Gait, Timothy S. Jain

Master's Theses

Total ankle replacement (TAR) implants are an effective option to restore the range of motion of the ankle joint for arthritic patients. An effective tool for analyzing these implants’ mechanical performance and longevity in-silico is finite element analysis (FEA). ABAQUS FEA was used to statically analyze the von Mises stress and contact pressure on the articulating surface of the bearing component in two newly installed fixed-bearing total ankle replacement implants (the Wright Medical INBONE II and the Exactech Vantage). This bearing component rotates on the talar component to induce primary ankle joint motion of plantarflexion and dorsiflexion. The stress response …


Effects Of Beet Supplements On Cardiovascular Response Using A Noninvasive Blood Pressure Cuff, Nicholas M. Hughes Dec 2023

Effects Of Beet Supplements On Cardiovascular Response Using A Noninvasive Blood Pressure Cuff, Nicholas M. Hughes

Master's Theses

A Calibrated Cuff Plethysmography device was built, tested for verification, and used to experiment on human subjects to measure the cardiovascular response of consuming a beet supplement, specifically looking at arterial compliance and pressure-area curves. Each subject was tested four times. A baseline was measured under normal conditions and after five-minute hyperemia conditions. 10 subjects were given 6 ounces of water mixed with either purple Kool-Aid (control), a SuperBeets supplement, or a SuperBeets Sport supplement and after 45 minutes, measurements were taken undergoing normal and hyperemia conditions once more. The verification testing demonstrated the calibration of the device was effectively …


Using Noninvasive Calibrated Cuff Plethysmography To Observe The Effects Of Cold-Water Immersion On Arterial Compliance, Rita M. Grigorian Oct 2023

Using Noninvasive Calibrated Cuff Plethysmography To Observe The Effects Of Cold-Water Immersion On Arterial Compliance, Rita M. Grigorian

Master's Theses

As the prevalence of cardiovascular diseases continues to exponentially grow in populations across the globe, the necessity of determining underlying factors, effective methods of diagnoses, and universally available preventive measures also grows. Early detection of endothelial dysfunction, a proven precursor of cardiovascular diseases, can be extremely impactful in encouraging preventative measures and early intervention before medical conditions become chronic. In recent years, ice plunging, a form of cryotherapy involving full body immersion in cold water, has gained popularity within circles of fitness and health practitioners, gaining the interest of people of all backgrounds. Certain parallels observed between the human physiological …


Static Vascular Modeling Of Diabetes Progression, Andrea Skattenborg Jun 2023

Static Vascular Modeling Of Diabetes Progression, Andrea Skattenborg

Master's Theses

Cardiovascular disease is the leading cause of mortality in diabetic patients, and diabetes is one of the main causes of cardiovascular disease. Risk factors for cardiovascular disease result in structural and functional changes in the vascular wall. Arterial stiffness is a prominent structural change observed in the arterial wall that can be measured in clinical settings. The purpose of this thesis was to create a static model of the changes in arterial stiffness seen in diabetes. Elastic tubes with varying wall thicknesses were used to create artificial arteries for this purpose. Compliance (inverse of stiffness) of the arteries was determined …


Analysis Of Arterial Compliance Using A Surrogate Arm Bench Top Model For The Validation Of Oscillometric Blood Pressure Methods, Christopher J. Cunningham Jun 2023

Analysis Of Arterial Compliance Using A Surrogate Arm Bench Top Model For The Validation Of Oscillometric Blood Pressure Methods, Christopher J. Cunningham

Master's Theses

A study was performed on a recently developed prototype of the Yong-Geddes surrogate arm design to collect compliance data of the various system components and determine the accuracy of measurements made through the bench top model. The study was performed to perceive the effectiveness of the model as a tool for validating non-invasive blood pressure detection monitors. Three stages of testing were performed to gather pressure and volume data from an artificial artery component, a sphygmomanometer, and the surrogate arm system to produce compliance estimations. Mathematical equations from supported arterial hemodynamics studies and clinical trials were applied to the pressure …


Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones Nov 2022

Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones

Master's Theses

This paper describes the design, manufacturing, and testing of a novel controllable hypoxic incubator with fully functional oxygen gas control and temperature control in a humid environment. On the current market, a majority of the few hypoxic incubators use pre-mixed gas that does not offer precise control over gas concentration. The objective for this project was to create a chamber that allows the user to set the O2 concentration to varying set points of % O2 while maintaining the chamber at a constant body temperature, CO2 level, humidity, and sterility. To start the project, multiple concepts were developed for the …


Integration Of Electrical Impedance Spectroscopy For Multichannel Cell Culture Measurement, Conard Chan Feb 2022

Integration Of Electrical Impedance Spectroscopy For Multichannel Cell Culture Measurement, Conard Chan

Master's Theses

ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY (EIS) has been widely used to study the electrical properties of biological material due to its non-invasive nature and experimental reliability. However, most of the precision impedance analyzers used in EIS only provide single- or two-channel measurements which are inadequate for larger-scale multiplexed measurements, such as those found in modern microfluidic cell culture experiments. The Biomedical Microsystems Laboratory has developed a 16-channel cell culture platform with integrated electrode arrays for monitoring cell growth and electrical properties (i.e., the so-called “electrical phenotype”). In this paper, a system consisting of a 16-channel solid-state analog multiplexer (MUX)paired with a low-cost, …


Microfluidic Electrical Impedance Spectroscopy System Automation And Characterization, Keaton Frahmann Jun 2021

Microfluidic Electrical Impedance Spectroscopy System Automation And Characterization, Keaton Frahmann

Master's Theses

In this work, a novel microfluidic cell culture platform capable of automated electrical impedance measurements and immunofluorescence and brightfield microscopy was developed for further in-vitro cellular research intended to optimize cell culture conditions. The microfluidic system design, fabrication, automation, and design verification testing are described. Electrical and optical measurements of the 16 parallel cell culture chambers were automated via a custom LabView interface. A proposed design change will enable gas diffusion, removing the need for an environmental enclosure and allow long-term cell culture experiments. This "lab on a chip" system miniaturizes and automates experiments improving testing throughput and accuracy while …


A Novel Method To Commercialize Medical Devices Initially Developed At California Polytechnic State University San Luis Obispo, Christina Grigorian Dec 2020

A Novel Method To Commercialize Medical Devices Initially Developed At California Polytechnic State University San Luis Obispo, Christina Grigorian

Master's Theses

California Polytechnic State University, San Luis Obispo is a university that encourages students to approach learning hands-on. As such, there is cutting-edge technology being developed by students in all departments on campus. Being that the university possesses an outstanding biomedical engineering department, there are groundbreaking medical devices that students are creating at Cal Poly SLO. These are devices that can better the lives of individuals suffering from ailments or fulfill needs in the medical industry. Subsequently, it is vital that these devices make it out of campus laboratories and into the hands of consumers. In order to move a product …


Analysis Of Electroanatomic Mapping System Accuracy Using X-Ray Reconstruction Of Electrode Locations In A Porcine Animal Model, Hana Boudlali Dec 2020

Analysis Of Electroanatomic Mapping System Accuracy Using X-Ray Reconstruction Of Electrode Locations In A Porcine Animal Model, Hana Boudlali

Master's Theses

Fluoroscopy is considered the gold standard for locating catheters during cardiac electrophysiology (EP) procedures. However, fluoroscopy emits ionizing radiation which can lead to adverse health effects when exposed to in high doses (World Health Organization, 2016). Electroanatomic mapping (EAM) systems display the three-dimensional location of EP catheters and measure the local electrical activity of the heart. They can minimize a physician’s reliance on fluoroscopy and can help reduce radiation exposure during a case (Casella, 2011).

EAM systems are diagnostic medical devices that inform the placement of ablation therapy and must accurately locate catheters to be deemed safe. Test methods to …


Insulative (Direct Current) Dielectrophoretic Foul-Less Filtration In Microfuidic Systems, Matthew A A Whitman Mar 2020

Insulative (Direct Current) Dielectrophoretic Foul-Less Filtration In Microfuidic Systems, Matthew A A Whitman

Master's Theses

Filtration is a technology that is used almost ubiquitously in society from uses raging from filtration of macroparticles from water to pharmaceutical grade filtration products to remove anything larger than a protein. However, with such a wide range of uses, most filtration products have the same issue; membrane clogging (fouling) that prevents continuous use and requires frequent maintenance. This thesis hypothesizes that by applying a direct current (DC) to an insulating array of posts, they will create a foul-less insulative dielectrophoretic filter (iDEP) that does not clog since particles will levitate above the insulating array.

This thesis tested an inherited …


Single-Cell Impedance Spectroscopy, David Paul Lange Dec 2019

Single-Cell Impedance Spectroscopy, David Paul Lange

Master's Theses

Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Biofluidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS system, an impedance spectroscopy bioMEMS chip was fabricated in the Cal Poly Microfabcrication lab, software was developed to run IS experiments, and studies were run to validate the system. To explore IS optimization, Maxwell’s mixture theorem and the Schwartz-Christoffel transform were used to calculate an analytic impedance solution to the co-planar electrode system,a novel volume fraction to account for …


Transmission Probability Of Embolic Debris Through The Aortic Arch And Daughter Vessels During A Transcatheter Aortic Valve Replacement Procedure, Jessica Lena Wirth Jun 2019

Transmission Probability Of Embolic Debris Through The Aortic Arch And Daughter Vessels During A Transcatheter Aortic Valve Replacement Procedure, Jessica Lena Wirth

Master's Theses

Cerebral ischemia leading to an ischemic stroke is a possible complication of a transcatheter aortic valve replacement (TAVR) procedure. This is because embolic debris can become dislodged and travel through the aortic arch, where they either continue to the descending aorta and join the systemic circulation or travel into the cerebral vasculature through the three daughter vessels that branch off the top of the aortic arch. These three vessels are the brachiocephalic artery, the left subclavian artery, and the left common carotid artery. These three vessels lead either directly or indirectly to the cerebral vasculature, where the diameter of vessels …


A 3-Dimensional In Silico Test Bed For Radiofrequency Ablation Catheter Design Evaluation And Optimization, Carolyn Teng Jun 2019

A 3-Dimensional In Silico Test Bed For Radiofrequency Ablation Catheter Design Evaluation And Optimization, Carolyn Teng

Master's Theses

Atrial fibrillation (AF) is the disordered activation of the atrial myocardium, which is a major cause of stroke. Currently, the most effective, minimally traumatic treatment for AF is percutaneous catheter ablation to isolate arrhythmogenic areas from the rest of the atrium. The standard in vitro evaluation of ablation catheters through lesion studies is a resource intensive effort due to tissue variability and visual measurement methods, necessitating large sample sizes and multiple prototype builds. A computational test bed for ablation catheter evaluation was built in SolidWorks® using the morphology and dimensions of the left atrium adjacent structures. From this geometry, the …


On-Demand Label Production, Robert A. Zimmerman May 2019

On-Demand Label Production, Robert A. Zimmerman

Master's Theses

The production and approval process for the various labels used in clinical trials wastes significant time and resources through the need to outsource label production or rely on large reams of pre-cut label stock for each revision throughout the process. An in-house, on-demand label printing and cutting system is a potential remedy to this waste. Previous work by Cheadle et al. resulted in a functional electomechanical prototype of the label cutting aspect of this research, capable of rudimentary linear cuts. In this continued research, emphasis was placed on improved label cutting capabilities and creating PC control software for label design. …


Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler Mar 2019

Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler

Master's Theses

Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …


Assessing Endothelial Dysfunction Estimating The Differences Between 3 Minute And 5 Minute Reactive Hyperemia, Tamiko K. Saldin Jan 2019

Assessing Endothelial Dysfunction Estimating The Differences Between 3 Minute And 5 Minute Reactive Hyperemia, Tamiko K. Saldin

Master's Theses

The purpose of this study was to define a lower standard cuff occlusion time to induce reactive hyperemia in assessing endothelial dysfunction. In this study, strong evidence was found by a novel technique that used oscillometric methods, which supported that 3 minute reactive hyperemia was sufficient to elicit a significant difference in arterial compliance from baseline. Twenty healthy Cal Poly students were assessed, (n=12 female, n=8 male) aged 22 years old with a standard deviation of 2.04 years. Arterial compliance was estimated by measuring the peak-to-peak oscillations for baseline, 3 minute reactive hyperemia, and 5 minute reactive hyperemia tests, with …


Microfluidic Electrical Impedance Spectroscopy, John J. Foley Sep 2018

Microfluidic Electrical Impedance Spectroscopy, John J. Foley

Master's Theses

The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …


Extended-Use Ecg Monitor, Daniel Aaron Soski Jun 2018

Extended-Use Ecg Monitor, Daniel Aaron Soski

Master's Theses

In this thesis, a prototype ECG monitor was developed that is integrated into an elastic shirt and takes a 3-lead ECG for over 5 days. The high-quality measurements can be used to identify markers indicative of various detrimental heart conditions. Measurements recorded by the device are encrypted and stored onto a micro-SD card. Current Holter monitors are expensive and have functional lives less than 48 hours; however, extended duration monitoring has been proven more useful in diagnosis. The device designed demonstrates that ECG measurements can be taken over longer durations without sacrificing quality, comfort, or device cost.


Eeg Characterization During Motor Tasks That Are Difficult For Movement Disorder Patients, Adam Joshua Aslam Dec 2017

Eeg Characterization During Motor Tasks That Are Difficult For Movement Disorder Patients, Adam Joshua Aslam

Master's Theses

Movement disorders are a group of syndromes that often arise due to neurological abnormalities. Approximately 40 million Americans are affected by some form of movement disorder, significantly impacting patients’ quality of life and their ability to live independently. Deep brain stimulation (DBS) is one treatment that has shown promising results in the past couple decades, however, the currently used open-loop system has several drawbacks. By implementing a closed-loop or adaptive DBS (aDBS) system, the need for expensive parameter reprogramming sessions would be reduced, side-effects may be relieved, and habituation could be avoided. Several biomarkers, for example signals or activity derived …


A 3-D Multiplex Paper-Microfluidic Platform, Mitchell Patrick Young Sep 2016

A 3-D Multiplex Paper-Microfluidic Platform, Mitchell Patrick Young

Master's Theses

3-D paper-based microfluidic devices (micoPADs) are small and portable devices made out of paper that offer a promising platform for diagnostic applications outside of a laboratory. These devices are easy to use, low cost, require no power source, and capable of detecting multiple targets simultaneously. The work in this thesis demonstrated the ability of a 3-D paper-microfluidic platform to simultaneously detect 5 targets. Rubber cord stock was used in conjunction with an acrylic housing unit to apply pressure along the edge of the channel. The indirect pressure application was successful in promoting vertical fluid flow between layers. Average channel development …


Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer Aug 2016

Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer

Master's Theses

Transcatheter aortic heart valve replacement (TAVR) is a procedure to replace a failing aortic valve and is becoming the new standard of care for patients that are not candidates for open-heart surgery [2]. However, this minimally invasive technique has shown to cause ischemic brain lesions, or “silent infarcts”, in 90% of TAVR patients, which can increase the patient’s risk for stroke by two to four times in future years [3]. Claret Medical Inc., a medical device company, has developed a cerebral protection system that filters and captures embolic debris released during endovascular procedures, such as TAVR. This thesis utilized CT …


Design And Analysis Of A Lift Assist Walker, Deep P. Shah Mar 2016

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley Mar 2016

Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley

Master's Theses

Despite significant preventative efforts, falls continue to be a major source of morbidity and mortality among the elderly. Additionally, the fear of falling can be a major obstacle to independent living for otherwise self-sufficient individuals. This fear is significantly heightened in individuals who have sustained a fall and often results in self-imposed restrictions on mobility and exercise, causing weakening in these individuals and further exacerbating the danger. Much time has been spent developing alert systems in an attempt to mitigate these problems. Unfortunately these systems typically involve dedicated monitoring centers and therefore often come with substantial upfront and recurring costs. …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon Jun 2015

Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon

Master's Theses

This thesis designed and fabricated various devices that were interfaced to an IC for an active contact lens that notifies the user of an event by detection of an external wireless signal. The contact lens consisted of an embedded antenna providing communication with a 2.4GHz system, as well as inductive charging at an operating frequency of 13.56 MHz. The lens utilized a CBC005 5µAh thin film battery by Cymbet and a manufactured graphene super capacitor as a power source. The custom integrated circuit (IC) was designed using the On Semiconductor CMOS C5 0.6 µm process to manage …


Micro Electrostatic Actuation Of A Silicon Diaphragm, Matthew W. Samples Jun 2015

Micro Electrostatic Actuation Of A Silicon Diaphragm, Matthew W. Samples

Master's Theses

There are a number of applications, from hearing aids to microfluidic pumps, which utilize micro-scale actuating diaphragms. These MEMS (micro-electromechanical system) devices can be actuated by electrostatic forces, which utilize an induced electric field to pull two charged plates towards one another. Such devices were fabricated and electrostatic actuation of the diaphragms was performed to analyze its viability as a micro-speaker. The long-term performance of such products requires adequate diaphragm deflection to create audible pressure waves with relatively low maximum stresses to ensure a high cycle fatigue life. With these requirements, initial calculations and FEA (finite element analysis) were performed …


Analysis Of Particles Thorough The Aortic Arch During Transcatheter Aortic Valve Replacement, Andrew Joseph Janicki Jun 2015

Analysis Of Particles Thorough The Aortic Arch During Transcatheter Aortic Valve Replacement, Andrew Joseph Janicki

Master's Theses

Ischemia caused by particles becoming dislodged during transcatheter aortic valve replacement (TAVR) is a possible complication of TAVR. The particles that become dislodged can travel out of the aortic valve, into the aortic arch, and then into either the brachiocephalic artery, the left common carotid artery, the left subclavian artery or continue into the descending aorta. If the particles continue into the descending aorta it poses no risk of causing ischemia however if it travels into the other arteries then it increases the possibility of the particle causing an ischemic event. The goal of this study is to determine what …


Evaluating The Effectiveness Of Cranial Molding For Treatment Of Positional Plagiocephaly Using Finite Element Analysis, Maziyar Keshtgar May 2015

Evaluating The Effectiveness Of Cranial Molding For Treatment Of Positional Plagiocephaly Using Finite Element Analysis, Maziyar Keshtgar

Master's Theses

Since the advent of recommendations for placing infants in the supine position during sleep to reduce the incidence of sudden infant death syndrome, clinicians have noted an increase in the frequency of cranial asymmetry due to deformation of suture sections of the infants’ skulls as a result of constant concentrated stress in one area at the back of their head. This specific form of cranial deformation is known as positional plagiocephaly and its rate of occurrence has increased from 0.3% in 8.2% within the past 30 years.

Current treatments and methodologies for preventing and correcting positional plagiocephaly such as stretching …