Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Structural Performance Of Single-Skin Glass Façade Systems Exposed To Fire, Mohamed Badr, Maged A. Youssef, Salah El-Din F. El-Fitiany, Ajitanshu Vedrtnam Aug 2022

Structural Performance Of Single-Skin Glass Façade Systems Exposed To Fire, Mohamed Badr, Maged A. Youssef, Salah El-Din F. El-Fitiany, Ajitanshu Vedrtnam

Civil and Environmental Engineering Publications

Purpose

Understanding the structural performance of external glass curtain walls (façades) during fire exposure is critical for the safety of the occupants, as their failure can lead to fire spread throughout the entire building. This concern is magnified by the recent increase in fire incidents and wildfires. This paper presents the first simplified technique to model single skin façades during fire exposure, and, then utilizes it to examine the structural behaviour of vertical, inclined, and oversized façade panels.

Design/methodology/approach

The proposed technique is based on conducting simplified heat transfer calculations, and, then utilizing a widely used structural analysis software to …


Steel Compression Members With Partial-Length Reinforcement, Morgan Herrell Apr 2016

Steel Compression Members With Partial-Length Reinforcement, Morgan Herrell

Electronic Thesis and Dissertation Repository

Steel wide-flange columns in existing truss bridges may be built-up with flange cover plate reinforcement to increase compressive capacity. This thesis investigates the use of partial-length steel cover plates about column mid-height to improve the weak-axis buckling resistance.

The present research first reviews literature concerning the Euler buckling of members with partial-length reinforcement. Inelastic buckling is simulated by 3-D finite element analysis accounting for cover plate length, cover plate area, bolt hole perforations, yield stresses, residual and locked-in dead load stresses, and initial out-of-straightness. The model is validated by a load test of a full-scale column with bolted reinforcement plates. …


Experimental And Numerical Study On Full-Scale Precast Steel Fibre-Reinforced Concrete Pipes, Nedal Mohamed Apr 2015

Experimental And Numerical Study On Full-Scale Precast Steel Fibre-Reinforced Concrete Pipes, Nedal Mohamed

Electronic Thesis and Dissertation Repository

Reinforced concrete (RC) pipes are widely used as open channels (non-pressurized pipes) for sewage and storm water conveyance. RC pipes have generally achieved a reliable long-term performance. Depending on multiple parameters (e.g. pipe diameter, pipe wall thickness, required strength, etc.) the pipe may have up to three welded reinforcement cages in order to resist anticipated loads. Each cage is an assembled unit of steel reinforcement consisting of circumferential and longitudinal bars or wires. The fabrication process of a steel cage reinforcement is time and labour consuming. Thus, eliminating the steel cage reinforcement will yield an overall reduction in the production …