Blood Flow Regulates Atherosclerosis Progression And Regression, Morgan A. Schake May 2023

Blood Flow Regulates Atherosclerosis Progression And Regression, Morgan A. Schake

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Atherosclerosis is the most prevalent pathology of cardiovascular disease with no known cure. Despite the many systemic risk factors for atherosclerosis, plaques do not form randomly in the vasculature. Instead, they form around bifurcations and the inner curvature of highly curving arterial segments that contain so-called disturbed blood flow that is low in magnitude and multidirectional over the cardiac cycle. Conversely, straight, non-bifurcated arterial segments that contain moderate-to-high and unidirectional (i.e., normal) blood flow are protected from plaque development. Thus, blood flow is a key regulator of atherosclerosis that may be able to be leveraged to develop new therapeutics. Towards …


Rheological Behavior Of Dspc-, Dbpc-, And Dppc-Oxygen Microbubbles And Their Effectiveness In Improving Survival In A Rat Model Of Lipopolysaccharide-Induced Acute Respiratory Distress Syndrome, Riaz Ur Rehman Mohammed May 2022

Rheological Behavior Of Dspc-, Dbpc-, And Dppc-Oxygen Microbubbles And Their Effectiveness In Improving Survival In A Rat Model Of Lipopolysaccharide-Induced Acute Respiratory Distress Syndrome, Riaz Ur Rehman Mohammed

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Acute respiratory distress syndrome (ARDS) causes 75,000 deaths in the U.S., annually. It is characterized by hypoxemia and damage to the lung alveoli. ARDS Management strategies involve extracorporeal membrane oxygenation (ECMO) and mechanical ventilation, but none of these methods improve the mortality rates. Oxygen microbubbles (OMBs) consist of a lipid shell with an oxygen core and have potential to augment oxygenation to manage ARDS. Previous studies demonstrated significant improvements in systemic oxygenation and mortality upon administering OMBs.

We replicated an ARDS rat model by intratracheal administration of lipopolysaccharide at a 24 mg/kg dose. After inducing the disease in rats, the …


A Single Cell Pair Mechanical Interrogation Platform To Study Cell-Cell Adhesion Mechanics, Amir Monemianesfahani Aug 2021

A Single Cell Pair Mechanical Interrogation Platform To Study Cell-Cell Adhesion Mechanics, Amir Monemianesfahani

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Cell-cell adhesion complexes are macromolecular adhesive organelles that integrate cells into tissues. Perturbations of the cell-cell adhesion structure or relatedmechanotransduction pathways lead to pathological conditions such as skin and heart diseases, arthritis, and cancer. Mechanical stretching has been used to stimulate the mechanotransduction process originating from the cell-cell adhesion and cell-extracellular matrix (ECM) complexes. The current techniques, however, have limitations on their ability to measure the cell-cell adhesion force directly and quantitatively. These methods use a monolayer of cells, which makes it impossible to quantify the forces within a single cell-cell adhesion complex. Other methods using single cells or cell …


Development Of An Intraperitoneal Catheter Placement Device For Use On The Battlefield, Riley Reynolds May 2021

Development Of An Intraperitoneal Catheter Placement Device For Use On The Battlefield, Riley Reynolds

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The objective of this project was to simplify peritoneal cavity access so an Airforce field medic can safely infuse oxygen microbubbles (OMBs) into the intraperitoneal space for the emergency treatment of hypoxia due to lung damage. To solve this problem, we created an intraperitoneal catheter placement device for use on the battlefield. The three common methods and some of the most common devices for peritoneal cavity access were reviewed. Injury frequencies for each of the three methods were analyzed. The results showed that each of the access techniques gives a similar rate of iatrogenic injury.

The battlefield conditions where the …


Ring And Peg Simulation For Minimally Invasive Surgical Robot, Evan Brown Apr 2018

Ring And Peg Simulation For Minimally Invasive Surgical Robot, Evan Brown

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Surgical procedures utilizing minimally invasive laparoscopic techniques have shown less complications, better cosmetic results, and less time in the hospital than conventional surgery. These advantages are partially offset by inherent difficulties of the procedures which include an inverted control scheme, instrument clashing, and loss of triangulation. Surgical robots have been designed to overcome the limitations, the Da Vinci being the most widely used. A dexterous in vivo, two-armed robot, designed to enter an insufflated abdomen with a limited insertion profile and expand to perform a variety of operations, has been created as a less expensive, versatile alternative to the Da …


Stretch Control Of Adipocyte Insulin Signaling, Tasneem Bouzid Aug 2017

Stretch Control Of Adipocyte Insulin Signaling, Tasneem Bouzid

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Obesity and related metabolic disorders have reached global epidemic proportions in recent decades. Excess and hypertrophic adipose tissue has been implicated in the development of various pathological diseases and disorders including Type-2 diabetes mellitus (Type-2 DM). In addition to serving as energy storage for the body, evidence also suggests that adipose tissue behaves as an endocrine organ capable of secreting bioactive cytokines known as adipokines, which mediate insulin signaling pathways in various tissues. Physical exercise has been demonstrated to positively affect insulin signaling activities potentially through increasing the secretion of insulin sensitizing adipokines and/or decreasing the secretion of pro-inflammatory insulin …


Development Of Peritoneal Microbubble Oxygenation As An Extrapulmonary Treatment For Hypoxia, Nathan Legband May 2017

Development Of Peritoneal Microbubble Oxygenation As An Extrapulmonary Treatment For Hypoxia, Nathan Legband

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Patients affected by a respiratory disease or injury experience a substantially impaired respiratory system and as a consequence are unable to obtain a sufficient amount of oxygen. Hypoxia can quickly result in developing permanent tissue damage or death. Currently, the medical methods of treating hypoxia are mechanical ventilation or extracorporeal membrane oxygenation. However, these treatments are ineffective in certain cases and possess significant additional risks including barotrauma, infection, hemorrhage, and thrombosis.

The extrapulmonary method of peritoneal oxygenation has been investigated by other research groups as a potential alternative to providing supplemental oxygen in hypoxic animals. In peritoneal oxygenation, the peritoneum, …


Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie May 2017

Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The invention of capsule endoscopy (CE) made the non-invasive monitoring of the entire small bowel possible and became the primary means for diagnosing small bowel pathology. In the last decade, capsule robots have been transformed from diagnostic devices into a widely studied biomedical platform with the potential for active locomotion, drug delivery and therapeutic capabilities. To perform accurate on-site drug release and therapy, it is necessary for a capsule robot to be able to attach to the intestinal tissue and maintain its position long-term. Design challenges derive from the task of long-term mucosal adhesion which requires firm, quick-response attachment without …


A Novel Biochamberfor Modeling Of Atherosclerotic Arteries: In-Vitro Capabilities And Applications, Iman Salafian, Angelos Karagiannis, Benjamin S. Terry, Yiannis S. Chatzizisis Apr 2017

A Novel Biochamberfor Modeling Of Atherosclerotic Arteries: In-Vitro Capabilities And Applications, Iman Salafian, Angelos Karagiannis, Benjamin S. Terry, Yiannis S. Chatzizisis

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Atherosclerosis is a chronic disease that involves the lipid accumulation and inflammation of the arterial wall [1,2]. Despite great efforts,its pathophysiology has not been fully elucidated. Existent drugs can reduce its progression but there are no available drugs to prevent its complications [3,4]. Atherosclerosis remains the leading global cause of death[5].

The purpose of this work is to design and build a customized biochamber which can be used for the following studies:

•Study the pathophysiology of atherosclerosis in vitro & ex vivo

•Investigate the mechanisms of atherosclerotic plaque disruption

•Examine the direct effect of different anti-atherosclerotic drugs on lesions

•Use …


Design Of A Flexible Control Platform And Miniature In Vivo Robots For Laparo-Endoscopic Single-Site Surgeries, Lou P. Cubrich Dec 2016

Design Of A Flexible Control Platform And Miniature In Vivo Robots For Laparo-Endoscopic Single-Site Surgeries, Lou P. Cubrich

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimally-invasive laparoscopic procedures have proven efficacy for a wide range of surgical procedures as well as benefits such as reducing scarring, infection, recovery time, and post-operative pain. While the procedures have many advantages, there are significant shortcomings such as limited instrument motion and reduced dexterity. In recent years, robotic surgical technology has overcome some of these limitations and has become an effective tool for many types of surgeries. These robotic platforms typically have an increased workspace, greater dexterity, improved ergonomics, and finer control than traditional laparoscopic methods. This thesis presents the designs of both a four degree-of-freedom (DOF) and 5-DOF …


Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum May 2016

Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Acute respiratory distress syndrome (ARDS) is a pulmonary disease that causes hypoxemia and respiratory failure. The mortality rate for ARDS ranges between 27% and 45%. Current treatments including mechanical ventilation and extracorporeal membrane oxygenation (ECMO) are often associated with high risk complications including barotrauma, infection, thrombosis, and hemorrhage. Alternative pulmonary support techniques are needed to improve the survival rate of patients suffering from ARDS. Previous studies introducing pure O2 gas, perfluorocarbons and red blood cells into the intraperitoneal (IP) cavity have reported no effect or only a mild increase in oxygenation. Here we report peritoneal membrane oxygenation (PMO) using …


Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch Apr 2016

Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

This thesis presents the design, controls, and testing of two systems: a novel colonoscope locomotion design for diagnostics, and a biosensor capsule that implants a sensor in the small intestine. Each system requires special design considerations for use in the gastrointestinal system.

Colonoscopy procedures are recommended as a screening for colon cancer and related conditions after the age of 50. The need for an improved colonoscope that reduces the colonoscopy time and patient discomfort is apparent. The semi-autonomous device presented here could likely reduce the colonoscopy procedure time by allowing the physician to focus more on the diagnosis and less …


Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer Nov 2015

Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Many studies aim to understand the fundamentals of kicking commonly displayed by soccer players [4,6,10,16,17,18,24,25,28,29,30,34,36,38,40]. Of those studies, most are limited to a two-dimensional (2D) analysis using high-speed cameras for position tracking or utilizing electromyography to observe the activity of select muscles [4,6,18,25,29,36]. The few studies that investigate kicking using a three-dimensional (3D) model are limited in their position tracking capabilities and focus mainly on joint flexion potentials and foot speed.

This dissertation is a comprehensive biomechanical analysis (kinematic and EMG) of the field-goal place-kicking techniques of four elite kickers in American football. Data were compared and contrasted with ball …


An Experimental Study Of The Implementation Of A Fluid Diode Inside A Sano Shunt, Patrick Austin Lane Sep 2014

An Experimental Study Of The Implementation Of A Fluid Diode Inside A Sano Shunt, Patrick Austin Lane

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Fluid diodes are fluidic devices that enhance fluid flow in a particular direction while inhibiting it in the opposite direction without the use of moving parts. This is accomplished through the use of nozzle shaped geometry on one side of the diode, and cusp shaped geometry on the opposing side. Fluid meets very little resistance as is travels though the nozzle side of the diode. The cusps on the other side of the diode reduce the effective flow area, thereby inhibiting flow. The objective of this study is to determine the effectiveness of a fluid diode installed in a reconstructed …


Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka Aug 2014

Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Paradigm shifts in invasiveness, recovery time, cosmesis, and cost have been seen within the field of general surgery through major advances in surgical technology. Some of the most advanced types of general surgery now include Minimally Invasive Surgery (MIS), LaparoEndoscopic Single-Site (LESS) surgery, and Natural Orifice Translumenal Endoscopic Surgery (NOTES). One of the newest and rapidly developing catalysts is robotic platforms. Such platforms have improved ergonomics and control, increased workspace and dexterity, and have surpassed the efficacy of many non-robotic platforms such as traditional laparoscopic surgical tools. This thesis presents the design and development of a four-degree-of-freedom (4- DOF) miniature …


Fluid Powered Miniature In-Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat Aug 2014

Fluid Powered Miniature In-Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.

Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …


Fluid Flow-Induced Mesenchymal Stem Cell Migration: Role Of Fak And Rock Mechanosensors, Brandon D. Riehl May 2014

Fluid Flow-Induced Mesenchymal Stem Cell Migration: Role Of Fak And Rock Mechanosensors, Brandon D. Riehl

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The study of mesenchymal stem cell (MSC) migration under mechanical stimulation conditions with investigation of the underlying molecular mechanism could lead to a better understanding and outcomes in stem cell-based regenerative medicine. MSCs having multipotent regenerative capability exist in niches in the bone marrow, muscle, vasculature, and in other tissues throughout the body, and their migration through tissues and vasculature for the repair of damaged tissue is a key process of cell and tissue homeostasis, remodeling, and regeneration. While cell migration in response to cytokines and other chemo-attractants is relatively well understood, little is revealed in regard to the effect …


Application Of Limited Mixing In The Hele-Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman Apr 2014

Application Of Limited Mixing In The Hele-Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

It is widely accepted that cells behave differently responding to the stiffness of their extracellular matrix (ECM). Such observations were made by culturing cells on hydrogel substrates of tunable stiffness. However, it was recently proposed that cells may sense how strongly they are tethered to ECM, not the local stiffness of ECM. To investigate both hypotheses, we developed a method to fabricate Janus polyacrylamide (PAAM) gels. We squeeze two drops of different concentrations in the Hele-Shaw geometry to generate radial Stokes flow. When the drops coalesce, limited mixing occurs at the interface due to the narrow confinement, and diffusion normal …


Near-Infrared Surface-Enhanced Fluorescence Using Silver Nanoparticles In Solution, Michael D. Furtaw Dec 2013

Near-Infrared Surface-Enhanced Fluorescence Using Silver Nanoparticles In Solution, Michael D. Furtaw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Fluorescence spectroscopy is a widely used detection technology in many research and clinical assays. Further improvement to assay sensitivity may enable earlier diagnosis of disease, novel biomarker discovery, and ultimately, improved outcomes of clinical care along with reduction in costs. Near-infrared, surface-enhanced fluorescence (NIR-SEF) is a promising approach to improve assay sensitivity via simultaneous increase in signal with a reduction in background. This dissertation describes research conducted with the overall goal to determine the extent to which fluorescence in solution may be enhanced by altering specific variables involved in the formation of plasmonactive nanostructures of dye-labeled protein and silver nanoparticles …


Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw Aug 2013

Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The concept of underactuation has been previously developed in the robotic field for grasping applications. For these anthropomorphic grippers, the minimization of the number of input signals, or in other words underactuation, is the most expected characteristic. This method has become very popular in recent decades. Indeed, by minimizing the number of input signals, it minimizes the complexity of the system’s control and at the same time avoids increased weight and cost. The inconvenience of such a technique is that the design of this type of system remains a difficult task if the behavior of the underactuated set of joints …


Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi Jul 2012

Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Laparo-Endoscopic Single Site (LESS) Robotics Surgery is an advanced technology in the field of Minimally Invasive Surgery (MIS). The LESS surgical robots significantly improve the surgeon’s accuracy, dexterity and visualization, and reduce the invasiveness of surgical procedure results in faster recovery time and improved cosmetic results. In a standard robotic endosurgery, the palpation of tissues is performed by laparoscopic graspers located at the end effectors. The master-slave configuration in robotic surgery leads in remote access to the operation site. Therefore, surgeon’s ability to perceive valuable sensory information is severely diminished. Sensory information such as haptics, which is essential for safe …


Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory May 2012

Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Adverse events due to medical errors are a leading cause of death in the United States exceeding the mortality rates of motor vehicle accidents, breast cancer and AIDS. Improvements can and should be made to reduce the rates of preventable surgical errors since they account for nearly half of all adverse events within hospitals. Although minimally invasive surgery has proven patient benefits such as reduced postoperative pain and hospital stay, its operative environment imposes substantial physical and cognitive strain on the surgeon increasing the risk of error. In order to mitigate errors and protect patients, a multidisciplinary approach was taken …


Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler Apr 2011

Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Gas emboli are a clinical issue often encountered in the space exploration, marine construction, and medical fields. Individuals involved with these disciplines will often have asympomatic gas emboli circulating throughout their bodies on a regular basis. A study into the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis in humans is thus presented. This research utilized a custom built cardiovascular flow simulator and accompanying data acquisition system to experimentally determine the influence of gas emboli under varied circumstances on the mean wall shear stress of a tube in-vitro. A directly inverse relationship between gas embolus presence in …


Material Modeling And Analysis For The Development Of A Realistic Blast Headform, S. G. M. Hossain Aug 2010

Material Modeling And Analysis For The Development Of A Realistic Blast Headform, S. G. M. Hossain

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Blast traumatic brain injury (BTBI) has become an important topic of study because of the increase of such incidents, especially due to the recent growth of improvised explosive devices (IEDs). This thesis discusses a project in which laboratory testing of BTBI was made possible by performing blast loading on experimental models simulating the human head. Three versions of experimental models were prepared – one having a simple geometry and the other two having geometry similar to a human head. For developing the head models, three important parts of the head were considered for material modeling and analysis – the skin, …


Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert Oct 2009

Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Laparoscopy is a minimally invasive alternative to traditional abdominal surgery. Unlike traditional surgery, a laparoscopic procedure can be completed using small incisions. The use of these small incision results in reduced pain to the patient, shorter recovery times, and less trauma to skin, muscle and other tissues. However, these benefits to the patient are offset by the increased difficulty to the surgeon performing the procedure. These difficulties include reduced dexterity, reduced perception, and longer procedure times. The use of small in vivo robotic devices in minimally invasive surgery is one possible solution to these problems. The movement of these devices …