Design, Development And Testing Of Web Services For Multi-Sensor Snow Cover Mapping, Jiri Kadlec Mar 2016

Design, Development And Testing Of Web Services For Multi-Sensor Snow Cover Mapping, Jiri Kadlec

Theses and Dissertations

This dissertation presents the design, development and validation of new data integration methods for mapping the extent of snow cover based on open access ground station measurements, remote sensing images, volunteer observer snow reports, and cross country ski track recordings from location-enabled mobile devices. The first step of the data integration procedure includes data discovery, data retrieval, and data quality control of snow observations at ground stations. The WaterML R package developed in this work enables hydrologists to retrieve and analyze data from multiple organizations that are listed in the Consortium of Universities for the Advancement of Hydrologic Sciences Inc …


A Comprehensive Python Toolkit For Harnessing Cloud-Based High-Throughput Computing To Support Hydrologic Modeling Workflows, Scott D. Christensen Feb 2016

A Comprehensive Python Toolkit For Harnessing Cloud-Based High-Throughput Computing To Support Hydrologic Modeling Workflows, Scott D. Christensen

Theses and Dissertations

Advances in water resources modeling are improving the information that can be supplied to support decisions that affect the safety and sustainability of society, but these advances result in models being more computationally demanding. To facilitate the use of cost- effective computing resources to meet the increased demand through high-throughput computing (HTC) and cloud computing in modeling workflows and web applications, I developed a comprehensive Python toolkit that provides the following features: (1) programmatic access to diverse, dynamically scalable computing resources; (2) a batch scheduling system to queue and dispatch the jobs to the computing resources; (3) data management for …


Perforated Hollow Core Waveguides For Alkali Vapor-Cells And Slow Light Devices, Matthieu C. Giraud Carrier Feb 2016

Perforated Hollow Core Waveguides For Alkali Vapor-Cells And Slow Light Devices, Matthieu C. Giraud Carrier

Theses and Dissertations

The focus of this work is the integration of alkali vapor atomic vapor cells into common silicon wafer microfabrication processes. Such integrated platforms enable the study of quantum coherence effects such as electromagnetically induced transparency, which can in turn be used to demonstrate slow light. Slow and stopped light devices have applications in the optical communications and quantum computing fields. This project uses hollow core anti-resonant reflecting optical waveguides (ARROWs) to build such slow light devices. An explanation of light-matter interactions and the physics of slow light is first provided, as well as a detailed overview of the fabrication process. …


Inversion Characteristics Of A Buoyant Cylindrical Puck During Oblique Water Impact, Zachary Crawford Smith Feb 2016

Inversion Characteristics Of A Buoyant Cylindrical Puck During Oblique Water Impact, Zachary Crawford Smith

Theses and Dissertations

The Apollo Command Module had a tendency to flip over upon impact with the ocean surface after returning from space (9/19 times). In an effort to better characterize the inversion process for future water landing vehicles, experimental results for a simplified buoyant cylindrical puck impacting the water surface are presented. This study focuses on the dependence of inversion upon vertical velocity, horizontal velocity, and the pitch angle of the puck relative to the free surface. High-speed images reveal an asymmetric cavity that forms upon water impact. The asymmetric cavity then collapses, applying a moment, which can be sufficient to invert …


Arctic Sea Ice Classification And Soil Moisture Estimation Using Microwave Sensors, David Brian Lindell Feb 2016

Arctic Sea Ice Classification And Soil Moisture Estimation Using Microwave Sensors, David Brian Lindell

Theses and Dissertations

Spaceborne microwave sensors are capable of estimating various properties of many geophysical phenomena, including the age and extent of Arctic sea ice and the relative soil moisture over land. The measurement and classification of such geophysical phenomena are used to refine climate models, localize and predict drought, and better understand the water cycle. Data from the active Ku-band scatterometers, the Quick Scatterometer (QuikSCAT), and the Oceansat-2 Scatterometer (OSCAT), are here used to classify areas of first-year and multiyear Arctic sea ice using a temporally adaptive threshold on reported radar backscatter values. The result is a 15-year data record of daily …


Microfluidic Devices And Biosensors, Long-Fang Tsai Feb 2016

Microfluidic Devices And Biosensors, Long-Fang Tsai

Theses and Dissertations

My research broadly covers various important aspects of microfluidic devices and biosensors. Specifically, this dissertation reports: (1) a new and effective room temperature method of bonding polydimethylsiloxane (PDMS) microfluidics to substrates such as silicon and glass, (2) a new microfluidic pump concept and implementation specifically designed to repeatedly drive a small sample volume (<1 µL) very rapidly (~500 µL/min) through a sensor-containing flow channel to significantly decrease sensor response time through advection-driven rather than diffusion-driven mass transport, (3) use of a new microfluidic material based on polyethylene glycol diacrylate (PEGDA) to implement impedance-based dynamic nanochannel sensors for protein sensing, and (4) an investigation of galvanoluminescence and how to avoid it for conditions important to fluorescence-based dielectrophoresis (DEP) microfluidic biosensors. Over the last decade, the Nordin research group has developed a lab-on-a-chip (LOC) biosensor based on silicon photonic microcantilever arrays integrated with polydimethylsiloxane (PDMS) microfluidics for protein biomarker detection. Integration requires reliable bonding at room temperature with adequate bond strength between the PDMS element and microcantilever sensor substrate. The requirement for a room temperature process is particularly critical because microcantilevers must be individually functionalized with antibody-based receptor molecules prior to bonding and cannot withstand significant heating after functionalization. I developed a new room temperature bonding method using PDMS curing agent as an intermediate adhesive layer. Two curing agents (Sylgard 184 and 182) were compared, as well as an alternate UV curable adhesive (NOA 75). The bond strength of Sylgard 184 was found to be stronger than Sylgard 182 under the same curing conditions. Overnight room temperature curing with Sylgard 184 yields an average burst pressure of 433 kPa, which is more than adequate for many PDMS sensor devices. In contrast, UV curable epoxy required a 12 hour bake at 50 °C to achieve maximum bond strength, which resulted in a burst pressure of only 124 kPa. In many biosensing scenarios it is desirable to use a small sample volume (<1 µL) to detect small analyte concentrations in as short a time as possible. I report a new microfluidic pump to address this need, which we call a reflow pump. It is designed to rapidly pump a small sample volume back and forth in a flow channel. Ultimately, the flow channel would contain functionalized sensor surfaces. The rapid flow permits use of advection-driven mass transport to the sensor surfaces to dramatically reduce sensor response times compared to diffusion-based mass transport. Normally such rapid flow would have the effect of decreasing the fraction of analyte molecules in the volume that would see the sensor surfaces. By configuring the pump to reflow fluid back and forth in the flow channel, the analyte molecules in the small sample volume are used efficiently in that they have many opportunities to make it to the sensor surfaces. I describe a 3-layer PDMS reflow pump that pumps 300 nL of fluid at 500 µL/min for 15 psi actuation pressure, and demonstrate a new two-layer configuration that significantly simplifies pump fabrication. Impedance-based nanochannel sensors operate on the basis of capturing target molecules in nanochannels such that impedance through the nanochannels is increased. While simple in concept, the response time can be quite long (8~12 hours) because the achievable flow rate through a nanochannel is very limited. An approach to dramatically increase the flow rate is to form nanochannels only during impedance measurements, and otherwise have an array of nanotrenches on the surface of a conventional microfluidic flow channel where they are exposed to normal microfluidic flow rates. I have implemented such a dynamic nanochannel approach with a recently-developed microfluidic material based polyethylene glycol diacrylate (PEGDA). I present the design, fabrication, and testing of PEGDA dynamic nanochannel array sensors, and demonstrate an 11.2 % increase in nanochannel impedance when exposed to 7.2 µM bovine serum albumin (BSA) in phosphate buffered saline (PBS). Recently, LOC biosensors for cancer cell detection have been demonstrated based on a combination of dielectrophoresis (DEP) and fluorescence detection. For fluorescence detection it is critical to minimize other sources of light in the system. However, reported devices use a non-noble metal electrode, indium tin oxide (ITO), to take advantage of its optical transparency. Unfortunately, use of non-noble metal electrodes can result in galvanoluminescence (GL) in which the AC voltage applied to the electrodes to achieve DEP causes light emission, which can potentially confound the fluorescence measurement. I designed and fabricated two types of devices to examine and identify conditions that lead to GL. Based on my observations, I have developed a method to avoid GL that involves measuring the impedance spectrum of a DEP device and choosing an operating frequency in the resistive portion of the spectrum. I also measure the emission spectrum of twelve salt solutions, all of which exhibited broadband GL. Finally, I show that in addition to Au, Cr and Ni do not exhibit GL, are therefore potentially attractive as low cost DEP electrode materials.


The Influence Of Season, Heating Mode And Slope Angle On Wildland Fire Behavior, Jonathan R. Gallacher Feb 2016

The Influence Of Season, Heating Mode And Slope Angle On Wildland Fire Behavior, Jonathan R. Gallacher

Theses and Dissertations

Wildland fire behavior research in the last 100 years has largely focused on understanding the physical phenomena behind fire spread and on developing models that can predict fire behavior. Research advances in the areas of live-fuel combustion and combustion modeling have highlighted several weaknesses in the current approach to fire research. Some of those areas include poor characterization of solid fuels in combustion modeling, a lack of understanding of the dominant heat transfer mechanisms in fire spread, a lack of understanding regarding the theory of live-fuel combustion, and a lack of understanding regarding the behavior of flames near slopes. In …


Real-Time Beamformer Development And Analysis Of Weak Signal Detection With Interference Mitigation For Phased-Array Feed Radio Astronomy, James Michael Brady Jan 2016

Real-Time Beamformer Development And Analysis Of Weak Signal Detection With Interference Mitigation For Phased-Array Feed Radio Astronomy, James Michael Brady

Theses and Dissertations

In recent years, the Brigham Young University (BYU) Radio Astronomy Systems group has developed phased-array feeds and the data acquisition processing systems necessary to perform radio astronomy observations. This thesis describes the development and testing of a real-time digital beamforming system that reduces both the time required to process phased-array feed data and the disk space used to record this data compared to post-processing beamforming systems. A real-data experiment is also discussed in this thesis, which focuses on some of the data post-processing required for one of BYU's data acquisition systems.Radio-frequency interference mitigation techniques for phased-array feed radio astronomy have …


Airborne Collision Detection And Avoidance For Small Uas Sense And Avoid Systems, Laith Rasmi Sahawneh Jan 2016

Airborne Collision Detection And Avoidance For Small Uas Sense And Avoid Systems, Laith Rasmi Sahawneh

Theses and Dissertations

The increasing demand to integrate unmanned aircraft systems (UAS) into the national airspace is motivated by the rapid growth of the UAS industry, especially small UAS weighing less than 55 pounds. Their use however has been limited by the Federal Aviation Administration regulations due to collision risk they pose, safety and regulatory concerns. Therefore, before civil aviation authorities can approve routine UAS flight operations, UAS must be equipped with sense-and-avoid technology comparable to the see-and-avoid requirements for manned aircraft. The sense-and-avoid problem includes several important aspects including regulatory and system-level requirements, design specifications and performance standards, intruder detecting and tracking, …