Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Engineering

Steel Compression Members With Partial-Length Reinforcement, Morgan Herrell Apr 2016

Steel Compression Members With Partial-Length Reinforcement, Morgan Herrell

Electronic Thesis and Dissertation Repository

Steel wide-flange columns in existing truss bridges may be built-up with flange cover plate reinforcement to increase compressive capacity. This thesis investigates the use of partial-length steel cover plates about column mid-height to improve the weak-axis buckling resistance.

The present research first reviews literature concerning the Euler buckling of members with partial-length reinforcement. Inelastic buckling is simulated by 3-D finite element analysis accounting for cover plate length, cover plate area, bolt hole perforations, yield stresses, residual and locked-in dead load stresses, and initial out-of-straightness. The model is validated by a load test of a full-scale column with bolted reinforcement plates. …


Behaviour Of Helical Pile Connectors For New Foundations, Muhammad Ahmad Muhammad Diab Sep 2015

Behaviour Of Helical Pile Connectors For New Foundations, Muhammad Ahmad Muhammad Diab

Electronic Thesis and Dissertation Repository

Despite the wide application of the connections between slender pile types, which end with a mono steel bar at the ground level (e.g. helical piles and micro piles), and new reinforced concrete foundations with limited width (e.g. RC grade beams) in the piling industry in North America, neither a clear understanding of the connections' behaviour nor a specific design criteria for their implementation is presented.

The main goal of this research was to clearly understand the behaviour of these connections and their failure mechanism under monotonic and cyclic loadings. The research methodology involved conducting experimental tests on 33 full-scale pile-foundation …


Compression Testing And Failure Modes Of Steel-Concrete Composite (Sc) Structures For Nuclear Containment, Patrick Michael Wanamaker, Amit H. Varma Oct 2013

Compression Testing And Failure Modes Of Steel-Concrete Composite (Sc) Structures For Nuclear Containment, Patrick Michael Wanamaker, Amit H. Varma

The Summer Undergraduate Research Fellowship (SURF) Symposium

Although being able to provide much cleaner power than burning coal and other fossil fuels, nuclear power plants are still a tough sell to the general public due to their history of being spontaneously dangerous. The containment structures surrounding these nuclear plants, however, can play a huge role in reducing the risks associated with them. Relatively new designs for these containment assemblies, known as SC (steel-concrete composite) structures, aim to increase the strength and durability of the containment facilities while keeping costs down. By varying the spacing between shear studs, the ratio of concrete to steel, and the ratio of …


Failure Analysis Of Impact-Damaged Metallic Poles Repaired With Fiber Reinforced Polymer Composites, Robert Arthur Slade Jan 2012

Failure Analysis Of Impact-Damaged Metallic Poles Repaired With Fiber Reinforced Polymer Composites, Robert Arthur Slade

Electronic Theses and Dissertations

Metallic utility poles, light poles, and mast arms are intermittently damaged by vehicle collision. In many cases the vehicular impact does not cause immediate failure of the structure, but induces localized damage that may result in failure under extreme service loadings or can promote degradation and corrosion within the damaged region. Replacement of these poles is costly and often involves prolonged lane closures, service interruption, and temporary loss of functionality. Therefore, an in situ repair of these structures is required. This thesis examines the failure modes of damaged metallic poles reinforced with externally-bonded fiber reinforced polymer (FRP) composites. Several FRP …