The Microstructure And The Electrochemical Behavior Of Cobalt Chromium Molybdenum Alloys From Retrieved Hip Implants, Christopher P. Emerson May 2015

The Microstructure And The Electrochemical Behavior Of Cobalt Chromium Molybdenum Alloys From Retrieved Hip Implants, Christopher P. Emerson

FIU Electronic Theses and Dissertations

Because of their excellent mechanical, tribological, and electrochemical properties, Cobalt Chromium Molybdenum alloys have been used as the material for both the stem and head of modular hip implants. Corrosion is one mechanism by which metal debris, from these implants, is generated, which can lead to adverse events that requires revision surgery. Manufacturing process such as wrought, as-cast, and powder metallurgy influences the microstructure, material properties, and performance of these implants

The current research focuses on analyzing the microstructure of CoCrMo alloys from retrieved hip implants with optical and scanning electron microscopy. Additionally, energy disperse spectroscopy was utilized to determine …


Magnetic Resonance Imaging Analysis Of Molecular Mobility During Dissolution Of Poly(Vinyl Alcohol) In Water, Balaji Narasimhan, J. E.M. Snaar, R. W. Bowtell, S. Morgan, C. D. Melia, N. A. Peppas Jan 1999

Magnetic Resonance Imaging Analysis Of Molecular Mobility During Dissolution Of Poly(Vinyl Alcohol) In Water, Balaji Narasimhan, J. E.M. Snaar, R. W. Bowtell, S. Morgan, C. D. Melia, N. A. Peppas

Balaji Narasimhan

Magnetic resonance imaging is used to study changing microstructure and molecular motion during dissolution of poly(vinyl alcohol) (PVA) in water. One-dimensional water concentration profiles were measured as a function of distance from the polymer-solvent interface. Diffusion-weighted profiles were used to calculate the spatial variation of the self-diffusion coefficient of water. The results indicate that diffusion coefficient values decrease toward the glassy core of the polymer. Self-diffusion coefficient values within the dissolving polymer increase with increasing dissolution time, while those near the polymer-solvent interface remain fairly constant. The effect of PVA molecular weight on the dissolution mechanism was investigated, with MÌ„n …


Room Temperature Aging Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Qiang Wu, Alan B. Carr, John C. Mitchell Jan 1995

Room Temperature Aging Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Qiang Wu, Alan B. Carr, John C. Mitchell

Cells and Materials

Specimens of three Pd-Cu-Ga dental alloys cast five years ago and subsequently stored at room temperature were reexamined and observed to have lower amounts of the eutectic constituents in the near-surface region than originally present, along with other microstructural changes. This previously unreported room temperature aging behavior of these alloys is attributed to the presence of high-diffusivity paths in the non-equilibrium ascast eutectic structures and to the essential role of the surface for the vacancy diffusion mechanism. These results may have important clinical significance for the ill vivo corrosion resistance and long-term biocompatibility of the Pd-Cu-Ga alloys.