Skip This Chore: Cleaning Your Air Conditioner Condenser Probably Won't Make It Work Better, David Yuill Jan 2019

Skip This Chore: Cleaning Your Air Conditioner Condenser Probably Won't Make It Work Better, David Yuill

Durham School of Architectural Engineering and Construction: Faculty Publications

I asked my neighbor who hoses off his air conditioner condenser every spring why he does it. “Because my dad always told me I had to,” he said.

Conventional wisdom like what my neighbor’s dad imparted may always seem right. But through my HVAC scholarship – the study of heating, ventilation and air-conditioning systems – I’ve learned that this particular presumption is probably wrong.


Prediction Of Stress Increase At Ultimate In Unbonded Tendons Using Sparse Principal Component Analysis, Eric Mckinney, Minwoo Chang, Marc Maguire, Yan Sun Jan 2019

Prediction Of Stress Increase At Ultimate In Unbonded Tendons Using Sparse Principal Component Analysis, Eric Mckinney, Minwoo Chang, Marc Maguire, Yan Sun

Durham School of Architectural Engineering and Construction: Faculty Publications

While internal and external unbonded tendons are widely utilized in concrete structures, an analytical solution for the increase in unbonded tendon stress at ultimate strength, fps, is challenging due to the lack of bond between strand and concrete. Moreover, most analysis methods do not provide high correlation due to the limited available test data. The aim of this paper is to use advanced statistical techniques to develop a solution to the unbonded strand stress increase problem, which phenomenological models by themselves have done poorly. In this paper, Principal Component Analysis (PCA), and Sparse Principal Component Analysis (SPCA) …


Need For Aeromedical Evacuation High-Level Containment Transport Guidelines, Shawn G. Gibbs, Jocelyn J. Herstein, Aurora B. Le, Elizabeth L. Beam, Theodore J. Cieslak, James V. Lawler, Joshua L. Santarpia, Terry L. Stentz, Kelli R. Kopocis-Herstein, Chandran Achutan, Gary W. Carter, John J. Lowe Jan 2019

Need For Aeromedical Evacuation High-Level Containment Transport Guidelines, Shawn G. Gibbs, Jocelyn J. Herstein, Aurora B. Le, Elizabeth L. Beam, Theodore J. Cieslak, James V. Lawler, Joshua L. Santarpia, Terry L. Stentz, Kelli R. Kopocis-Herstein, Chandran Achutan, Gary W. Carter, John J. Lowe

Durham School of Architectural Engineering and Construction: Faculty Publications

Circumstances exist that call for the aeromedical evacuation high-level containment transport (AE-HLCT) of patients with highly hazardous communicable diseases. A small number of organizations maintain AE-HLCT capabilities, and little is publicly available regarding the practices. The time is ripe for the development of standards and consensus guidelines involving AE-HLCT.


A Practitioner’S Guide To Small Unmanned Aerial Systems For Bridge Inspection, Sattar Dorafshan, Robert J. Thomas, Calvin Coopmans, Marc Maguire Jan 2019

A Practitioner’S Guide To Small Unmanned Aerial Systems For Bridge Inspection, Sattar Dorafshan, Robert J. Thomas, Calvin Coopmans, Marc Maguire

Durham School of Architectural Engineering and Construction: Faculty Publications

Small unmanned aerial system(s) (sUAS) are rapidly emerging as a practical means of performing bridge inspections. Under the right condition, sUAS assisted inspections can be safer, faster, and less costly than manned inspections. Many Departments of Transportation in the United States are in the early stages of adopting this emerging technology. However, definitive guidelines for the selection of equipment for various types of bridge inspections or for the possible challenges during sUAS assisted inspections are absent. Given the large investments of time and capital associated with deploying a sUAS assisted bridge inspection program, a synthesis of authors experiences will be …


Benchmarking Image Processing Algorithms For Unmanned Aerial System-Assisted Crack Detection In Concrete Structures, Sattar Dorafshan, Robert J. Thomas, Marc Maguire Jan 2019

Benchmarking Image Processing Algorithms For Unmanned Aerial System-Assisted Crack Detection In Concrete Structures, Sattar Dorafshan, Robert J. Thomas, Marc Maguire

Durham School of Architectural Engineering and Construction: Faculty Publications

This paper summarizes the results of traditional image processing algorithms for detection of defects in concrete using images taken by Unmanned Aerial Systems (UASs). Such algorithms are useful for improving the accuracy of crack detection during autonomous inspection of bridges and other structures, and they have yet to be compared and evaluated on a dataset of concrete images taken by UAS. The authors created a generic image processing algorithm for crack detection, which included the major steps of filter design, edge detection, image enhancement, and segmentation, designed to uniformly compare dierent edge detectors. Edge detection was carried out by six …


Remotely Testing Whether A Climate Control System Controller Is Correctly Installed, Fadi M. Alsaleem Jan 2019

Remotely Testing Whether A Climate Control System Controller Is Correctly Installed, Fadi M. Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

Disclosed are exemplary embodiments of apparatus and methods for remote testing of controllers such as thermostats, to detect incorrect climate control system configuration parameters . In an exemplary embodiment, a computer wirelessly connects with a remote thermostat and sends signal (s) to the thermostat instructing the thermostat to perform climate control function (s) in predefined sequence (s). The computer receives signal (s) from the thermostat indicating whether the thermostat is performing the climate control function (s) in accordance with the sent signal (s). Based on the signal (s) received from the thermostat, the computer determines whether the thermostat is configured …


Method Of Monitoring Charge Condition Of Heat Pump System, Fadi M. Alsaleem, Gregg M. Hemmelgarn Jan 2019

Method Of Monitoring Charge Condition Of Heat Pump System, Fadi M. Alsaleem, Gregg M. Hemmelgarn

Durham School of Architectural Engineering and Construction: Faculty Publications

A heat-pump circuit may include an indoor heat exchanger, an outdoor heat exchanger, a compressor adapted to circulate a working fluid between the indoor and outdoor heat exchangers, and an expansion device disposed between the indoor and outdoor heat exchangers. A monitor for the heat-pump system may include a return-air temperature sensor, a supply-air temperature sensor, and a processor. The return-air temperature sensor may be adapted to measure a first air temperature of air upstream of the indoor heat exchanger. The supply-air temperature sensor may be adapted to measure a second air temperature of air down stream of the indoor …


Hvac System Remote Monitoring And Diagnosis, Jeffrey N. Arensmeier, Gregg M. Hemmelgarn, Fadi M. Alsaleem, Priotomo Abiprojo Jan 2019

Hvac System Remote Monitoring And Diagnosis, Jeffrey N. Arensmeier, Gregg M. Hemmelgarn, Fadi M. Alsaleem, Priotomo Abiprojo

Durham School of Architectural Engineering and Construction: Faculty Publications

A monitoring system for an HVAC system of a building includes a monitoring server located remotely from the building. The monitoring server receives, from a device installed at the building, (i) time-domain current data based on a measured aggregate current supplied to a plurality of components of the HVAC system, and (ii) data based on frequency-domain current data of the measured aggregate current. Based on the received data, the monitoring server accesses (i) whether a failure has occurred in a first com ponent of the plurality of components and (ii) generates a preliminary advisory in response to determining that the …


Building Envelope And Interior Grading Systems And Methods, Fadi Mohammad Alsaleem Jan 2019

Building Envelope And Interior Grading Systems And Methods, Fadi Mohammad Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

A difference module determines differences between an outdoor ambient temperature and an indoor temperature, determines a first average of the differences , and determines a second average of the differences. A storing module stores a first data point, the first data point including the first average and a first total run time of a heating, ventilation, and/or air conditioning (HVAC) system, and stores a second data point, the second data point including the second average and a second total run time of the HVAC system. A fitting module fits a line to the first and second data points. An envelope …


Heat Pump And Air Conditioning Grading Systems And Methods, Fadi Mohammad Alsaleem Jan 2019

Heat Pump And Air Conditioning Grading Systems And Methods, Fadi Mohammad Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

An expectation module determines an expected average power consumption of a heat pump for a predetermined period as a function of indoor and outdoor temperatures of the building during the predetermined period. A difference module determines a power difference between an average power consumption of the heat pump during the predeter mined period and the expected average power consumption of the heat pump for the predetermined period. A grade determination module determines a grade of the heat pump for the predetermined period based on the power difference of the predetermined period. A reporting module generates a displayable report including the …


Hvac System Air Filter Diagnostics And Monitoring, Priotomo Abiprojo, Fadi M. Alsaleem Jan 2019

Hvac System Air Filter Diagnostics And Monitoring, Priotomo Abiprojo, Fadi M. Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

A system and method for monitoring a heating, ventilation, or air conditioning (HVAC) system of a building is provided. A monitoring server, located remotely from the building, receives operating parameter data from a monitoring device at the building that measures an operating parameter of the HVAC system. The monitoring server generates a plurality of data clusters from the operating parameter data, each data cluster corresponding to operating parameter data generated during steady-state operation of the HVAC system. The monitoring server calculates an average operating parameter value for each data cluster. The monitoring server calculates normalized operating parameter values based on …