Full-Text Articles in Architecture

Effects Of Noise, Reverberation And Foreign Accent On Native And Non-Native Listeners’ Performance Of English Speech Comprehension, Zhao Ellen Peng, Lily M. Wang May 2016

Effects Of Noise, Reverberation And Foreign Accent On Native And Non-Native Listeners’ Performance Of English Speech Comprehension, Zhao Ellen Peng, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

A large number of non-native English speakers may be found in American classrooms, both as listeners and talkers. Little is known about how this population comprehends speech in realistic adverse acoustical conditions. A study was conducted to investigate the effects of background noise level (BNL), reverberation time (RT), and talker foreign accent on native and non-native listeners' speech comprehension, while controlling for English language abilities. A total of 115 adult listeners completed comprehension tasks under 15 acoustic conditions: three BNLs (RC-30, RC-40, and RC-50) and five RTs (from 0.4 to 1.2 s). Fifty-six listeners were tested with speech from native …


Experimental Study On The Thermal Characteristics Of Micro Channel Separate Heat Pipe Respect To Different Filling Ratio, Li Ling, Quan Zhang, Yuebin Yu, Shuguang Liao, Zhengyong Sha Mar 2016

Experimental Study On The Thermal Characteristics Of Micro Channel Separate Heat Pipe Respect To Different Filling Ratio, Li Ling, Quan Zhang, Yuebin Yu, Shuguang Liao, Zhengyong Sha

Durham School of Architectural Engineering and Construction: Faculty Publications

A micro channel separate heat pipe (MCSHP) that can use natural cold energy was developed to reduce the cooling energy consumptions of telecommunications stations (TSs). Experimental investigations of exploring the optimal refrigerant filling ratio of MCSHP under different outdoor conditions and flow rates were presented. R22 was used as the working fluid. Various refrigerant filling ratios were tested in an enthalpy difference laboratory (EDL) in order to determine the optimal thermal performance for the exterior space temperature range from 8 °C to 23 °C and the air volume flow rate range from 1712 m3/h to 2980 m3/h. In addition, transient …


Case Study Of Quantifying Energy Loss Through Ceiling-Attic Recessed Lighting Fixtures Through 3d Numerical Simulation, Ri Na, Shengmao Lin, Zhigang Shen, Linxia Gu Jan 2016

Case Study Of Quantifying Energy Loss Through Ceiling-Attic Recessed Lighting Fixtures Through 3d Numerical Simulation, Ri Na, Shengmao Lin, Zhigang Shen, Linxia Gu

Durham School of Architectural Engineering and Construction: Faculty Publications

Air leakage through improperly installed recessed lighting fixtures has been identified as a common issue causing extra energy consumption of residential buildings. However, little quantitative study was found in this area. In this paper, a preliminary evaluation of the magnitude of such energy loss was conducted by numerical simulations using 3 dimensional transient computational fluid dynamics (CFD) model. A typical layout of recessed lighting fixtures was used in this case study with boundary conditions in four different seasons, which were obtained from past measured roof/attic temperature data sets. The results of the numerical simulations indicate that leakage of recessed lighting …


A Thermo-Activated Wall For Load Reduction And Supplementary Cooling With Free To Low-Cost Thermal Water, Yuebin Yu, Fuxin Niu, Heinz-Axel Guo, Denchai Woradechjumroen Jan 2016

A Thermo-Activated Wall For Load Reduction And Supplementary Cooling With Free To Low-Cost Thermal Water, Yuebin Yu, Fuxin Niu, Heinz-Axel Guo, Denchai Woradechjumroen

Durham School of Architectural Engineering and Construction: Faculty Publications

A building envelope serves as a thermal barrier and plays an important role in determining the amount of energy used to achieve a comfortable indoor environment. Conventionally, it is constructed and treated as a passive component in a building thermal energy system. In this article, a novel, mini-tube capillary-network embedded and thermal-water activated building envelope is proposed to turn the passive component into active, therefore broaden the direct utilization of low-grade thermal energy in buildings. With this proposed approach, low-grade thermal water at a medium temperature close to the ambient environment can be potentially utilized to either counterbalance the thermal …


Student Absenteeism And The Comparisons Of Two Sampling Procedures For Culturable Bioaerosol Measurement In Classrooms With And Without Upper Room Ultraviolet Germicidal Irradiation Devices, Chunxiao Su, Josephine Lau, Shawn G. Gibbs Jan 2016

Student Absenteeism And The Comparisons Of Two Sampling Procedures For Culturable Bioaerosol Measurement In Classrooms With And Without Upper Room Ultraviolet Germicidal Irradiation Devices, Chunxiao Su, Josephine Lau, Shawn G. Gibbs

Durham School of Architectural Engineering and Construction: Faculty Publications

Upper room ultraviolet germicidal irradiance (UVGI) has been shown to reduce the concentration of bioaerosols in controlled chambers. However, there is a lack of experimental results on the reduction of bioaerosol concentrations by UVGI devices in actual uncontrolled buildings. This study was carried out in an American elementary school in the Midwest. Two sampling procedures were carried out in six selected classrooms with similar dimensions that were separated into two groups: (1) UVGI exposure group and (2) non-UVGI control group. Two-stage Tisch culturable impactors were utilized to collect airborne culturable bacteria and fungi. Monthly samples were collected during unoccupied period …


A Need For Evidence-Based And Multidisciplinary Research To Study The Effects Of The Interaction Of School Environmental Conditions On Student Achievement, Josephine Lau, Lily M. Wang, Clarence E. Waters, James A. Bovaird Jan 2016

A Need For Evidence-Based And Multidisciplinary Research To Study The Effects Of The Interaction Of School Environmental Conditions On Student Achievement, Josephine Lau, Lily M. Wang, Clarence E. Waters, James A. Bovaird

Durham School of Architectural Engineering and Construction: Faculty Publications

With funding from the U.S. Environmental Protection Agency’s (EPA) Healthy Schools initiative, a research team from the University of Nebraska– Lincoln (UNL) is currently working on establishing how environmental conditions in K-12 school buildings impact student scholastic achievement. The objectives of the research project are: (1) to study comprehensively the impacts of a wide set of indoor environmental factors (including indoor air quality, thermal, lighting and acoustic conditions) on student achievement; (2) to investigate how these environmental conditions interact with each other to impact student achievement; (3) to rank order the environmental variables in terms of their relative impact on …


Fault Detection And Diagnosis Process For Oversizing Design On Multiple Packaged Air-Conditioning Units, Denchai Woradechjumroen, Haorong Li, Thanapat Promwattanapakee Jan 2016

Fault Detection And Diagnosis Process For Oversizing Design On Multiple Packaged Air-Conditioning Units, Denchai Woradechjumroen, Haorong Li, Thanapat Promwattanapakee

Durham School of Architectural Engineering and Construction: Faculty Publications

Heating, ventilation, air-conditioning and Refrigeration (HVAC&R) systems are seldom designed or commissioned properly. The situation leads to abrupt or degradation faults resulting in inefficient energy uses, excessive energy consumption and high service costs. To solve these aforementioned problems, fault detection and diagnosis (FDD) is utilized to firstly detect any abnormal conditions of a system and then diagnoses and determines their causes. In order to apply this concept in HVAC oversizing designs, this paper proposes the state-of-art procedure of a FDD procedure for analyzing the inherently faulty design (oversizing) of multiple packaged air-conditioning units used to supply cooling for an open …


Development Of Coordination Control For Multiple Rooftop Units, Denchai Woradechjumroen, Haorong Li, Akekachai Deesiri Jan 2016

Development Of Coordination Control For Multiple Rooftop Units, Denchai Woradechjumroen, Haorong Li, Akekachai Deesiri

Durham School of Architectural Engineering and Construction: Faculty Publications

Rooftop Units (RTUs) have been widely applied in providing space heating and cooling for commercial buildings. In total, they serve over 60% of the commercial building floor space in the U.S. Even through the current control approaches of a RTU can maintain the zone temperature corresponding to a set point temperature, it performs inefficiently due to several factors such as limited sensing capability, non- coordinated local control, inherent oversizing effects and so on. In addition to unnecessary power consumptions, the current control and operation technology on RTUs also lead to the space humidity problem, equipment efficiency degradation, and premature failure. …


Cognitive Radio For Smart Grid With Security Considerations, Khaled Shuaib, Ezedin Barka, Nedaa Al Hussien, Mohammed Abdel-Hafez, Mahmoud Alahmad Jan 2016

Cognitive Radio For Smart Grid With Security Considerations, Khaled Shuaib, Ezedin Barka, Nedaa Al Hussien, Mohammed Abdel-Hafez, Mahmoud Alahmad

Durham School of Architectural Engineering and Construction: Faculty Publications

In this paper, we investigate how Cognitive Radio as a means of communication can be utilized to serve a smart grid deployment end to end, from a home area network to power generation. We show how Cognitive Radio can be mapped to integrate the possible different communication networks within a smart grid large scale deployment. In addition, various applications in smart grid are defined and discussed showing how Cognitive Radio can be used to fulfill their communication requirements. Moreover, information security issues pertained to the use of Cognitive Radio in a smart grid environment at different levels and layers are …


Compressor Having A Control And Dagnostic Module, Hung M. Pham, Fadi M. Alsaleem Jan 2016

Compressor Having A Control And Dagnostic Module, Hung M. Pham, Fadi M. Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

An apparatus includes a Voltage sensor, a current sensor, and a controller. The Voltage sensor measures Voltage values of alternating current power Supplied to a capacitor. The capaci tor is electrically coupled to a compressor. The current sensor measures current values of the alternating current power. The controller is configured to receive the Voltage values and the current values. The controller is configured to determine a first power factor value based on at least one of the voltage values and at least one of the current values. The controller is configured to selectively detect a first capacitor fault in response …


A Prediction Method For Overall Economic Value Of Fault Detection And Diagnostic Tools For Rooftop And Split Systems, David Yuill, James Braun Jan 2016

A Prediction Method For Overall Economic Value Of Fault Detection And Diagnostic Tools For Rooftop And Split Systems, David Yuill, James Braun

Durham School of Architectural Engineering and Construction: Faculty Publications

Fault detection and diagnostics (FDD) tools for air-conditioning application may perform well or poorly, but it is difficult to characterize this performance in a meaningful way. Some recently proposed evaluation techniques have provided various statistics to characterize FDD performance, but these results can be difficult for a potential adopter of FDD to understand. A new method of characterizing FDD performance by predicting the overall economic value of the FDD tool is proposed in this paper. It is applicable to FDD tools intended for air-cooled unitary airconditioners, such as rooftop units (RTU) and split systems. The method gives an estimated dollar …


Normalized Effect Of Condenser Fouling And Refrigerant Charge On Performance Of Vapor Compression Air Conditioning Systems, Mehdi Mehrabi, David Yuill Jan 2016

Normalized Effect Of Condenser Fouling And Refrigerant Charge On Performance Of Vapor Compression Air Conditioning Systems, Mehdi Mehrabi, David Yuill

Durham School of Architectural Engineering and Construction: Faculty Publications

Several laboratory experiments have studied the effect of faults on vapor compression cycle air-conditioning systems. There has been a particular focus on refrigerant charge variation, which is believed to be quite common in air conditioners, and a lesser focus on heat exchanger fouling. The majority of the published results evaluate the fault effects on particular system operating parameters in one unit. For example, the effect on capacity and efficiency are typically evaluated. The results differ from one study to the next. The current paper summarizes the effects for all of the results available in the literature for condenser fouling and …


Fault Diagnosis Of Refrigerant Charge Based On Pca And Decision Tree For Variable Refrigerant Flow Systems, Jiangyan Liu, Huanxin Chen, Jiangyu Wang, Guannan Li, Haorong Li, Wenju Hu Jan 2016

Fault Diagnosis Of Refrigerant Charge Based On Pca And Decision Tree For Variable Refrigerant Flow Systems, Jiangyan Liu, Huanxin Chen, Jiangyu Wang, Guannan Li, Haorong Li, Wenju Hu

Durham School of Architectural Engineering and Construction: Faculty Publications

Variable refrigerant flow (VRF) systems are easily subjected to performance degradation due to refrigerant leakage, mechanical failure or improper maintenance after years of operation. Ideal VRF systems should equip with fault detection and diagnosis (FDD) program to sustain its normal operation. This paper presents the fault diagnosis method for refrigerant charge faults of variable refrigerant flow (VRF) systems. It is developed based on the classification and regression tree (CART) algorithm. Data of the experimental VRF system is used to test the advantages of the CART method. Results show that the decision tree can achieve desirable diagnosis efficiency on undercharge faults, …