Open Access. Powered by Scholars. Published by Universities.®

Social and Behavioral Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Social and Behavioral Sciences

Effects Of High And Low Breast Support On Breast Kinematics And Kinetics During Treadmill Running, Deirdre Mcghee, Julie R. Steele, William J. Zealey Jan 2010

Effects Of High And Low Breast Support On Breast Kinematics And Kinetics During Treadmill Running, Deirdre Mcghee, Julie R. Steele, William J. Zealey

Faculty of Health and Behavioural Sciences - Papers (Archive)

Results: The mean vertical component of the peak bra/breast spring force during treadmill running was greatest during the downward breast trajectory and was approximately 30% less in the high breast support condition (13 N ± 7 N) compared to the low support condition (17 N ± 10 N). This force reduction was accompanied by a 300% decrease in breast and bra discomfort. Conclusion: Wearing a well-fitted supportive sports bra is recommended for females with large breasts to reduce the breast forces and, in tum, exercise induced breast and bra discomfort during physical activity such as treadmill running.


The Effect Of Exercise On The Skeletal Muscle Phospholipidome Of Rats Fed A High-Fat Diet, Todd W. Mitchell, N. Turner, Paul Else, Anthony J. Hulbert, John Hawley, Jong Sam Lee, Clinton Bruce, Stephen J. Blanksby Jan 2010

The Effect Of Exercise On The Skeletal Muscle Phospholipidome Of Rats Fed A High-Fat Diet, Todd W. Mitchell, N. Turner, Paul Else, Anthony J. Hulbert, John Hawley, Jong Sam Lee, Clinton Bruce, Stephen J. Blanksby

Faculty of Health and Behavioural Sciences - Papers (Archive)

The aim of this study was to examine the effect of endurance training on skeletal muscle phospholipid molecular species from high-fat fed rats. Twelve female Sprague- Dawley rats were fed a high-fat diet (78.1% energy). The rats were randomly divided into two groups, a sedentary control group and a trained group (125 min of treadmill running at 8 m/min, 4 days/wk for 4 weeks). Forty-eight hours after their last training bout phospholipids were extracted from the red and white vastus lateralis and analyzed by electrospray-ionization mass spectrometry. Exercise training was associated with significant alterations in the relative abundance of a …


High Plantar-Flexor Passive Stiffness Increases Achilles Tendon Loading During Landings, John Whitting, Julie R. Steele, Deirdre Mcghee, Bridget J. Munro Jan 2010

High Plantar-Flexor Passive Stiffness Increases Achilles Tendon Loading During Landings, John Whitting, Julie R. Steele, Deirdre Mcghee, Bridget J. Munro

Faculty of Health and Behavioural Sciences - Papers (Archive)

No abstract provided.


Determination Of Consumer Context In An Online Transaction Process For A High Risk Purchase, Robert G. Grant, Rodney J. Clarke, Elias Kyriazis Jan 2010

Determination Of Consumer Context In An Online Transaction Process For A High Risk Purchase, Robert G. Grant, Rodney J. Clarke, Elias Kyriazis

Faculty of Commerce - Papers (Archive)

This paper showcases/discusses a method of analyzing consumer website behavior that enables real-time purchase context identification. Such analysis will enable online vendors to serve content that is relevant to the consumer’s needs, addressing the apparent utility deficit that websites have for complex product transactions. The use of communication theory is a key component of a value co-creation process that leverages the data derived from website interactivity by analyzing the meaning of consumer activity on a website. Such an approach offers insights into the effect of information accessed by consumers in real time, enabling a responsive system for serving information in …


Global Estimates Of Co Sources With High Resolution By Adjoint Inversion Of Multiple Satellite Datasets (Mopitt, Airs, Sciamachy, Tes), M Kopacz, D J. Jacob, J A. Fisher, J A. Logan, L Zhang, I A. Megretskaia, R M. Yantosca, K Singh, D K. Henze, J P. Burrows, M Buchwitz, I Khlystova, W. W Mcmillan, J C. Gille, D P. Edwards, A Eldering, V Thouret, P Nedelec Jan 2010

Global Estimates Of Co Sources With High Resolution By Adjoint Inversion Of Multiple Satellite Datasets (Mopitt, Airs, Sciamachy, Tes), M Kopacz, D J. Jacob, J A. Fisher, J A. Logan, L Zhang, I A. Megretskaia, R M. Yantosca, K Singh, D K. Henze, J P. Burrows, M Buchwitz, I Khlystova, W. W Mcmillan, J C. Gille, D P. Edwards, A Eldering, V Thouret, P Nedelec

Faculty of Science - Papers (Archive)

We combine CO column measurements from the MOPITT, AIRS, SCIAMACHY, and TES satellite instruments in a full-year (May 2004–April 2005) global inversion of CO sources at 4◦ ×5◦ spatial resolution and monthly temporal resolution. The inversion uses the GEOS-Chem chemical transport model (CTM) and its adjoint applied to MOPITT, AIRS, and SCIAMACHY. Observations from TES, surface sites (NOAA/GMD), and aircraft (MOZAIC) are used for evaluation of the a posteriori solution. Using GEOSChem as a common intercomparison platform shows global consistency between the different satellite datasets and with the in situ data. Differences can be largely explained by different averaging kernels …


Variation In Seagrass Biomass Estimates In Low And High Density Settings: Implications For The Selection Of Sample Size, Mustafa K. Hossain, Kerrylee Rogers, Neil Saintilan Jan 2010

Variation In Seagrass Biomass Estimates In Low And High Density Settings: Implications For The Selection Of Sample Size, Mustafa K. Hossain, Kerrylee Rogers, Neil Saintilan

Faculty of Science, Medicine and Health - Papers: part A

Few seagrass biomass monitoring studies have considered the adequacy of monitoring intensity in their design. Power analysis is now widely used in ecological monitoring to determine sample size (replication) and the power (probability of not making a Type II error) of the monitoring design to detect change (effect size). We investigated seasonal variation of above-ground biomass of Zostera species at Woolooware Bay, Botany Bay, NSW and Ukerebagh Channel, Tweed River, NSW to show that seagrass biomass varies significantly between sites and seasonally. By conducting preliminary power analysis at each study site we found that our sampling design would only detect …


High-Energy, Picosecond, Cryogenic Yb:Yag Chirped-Pulse Amplifier At Khz Repetition Rates For Opcpa Pumping, Kyung-Han Hong, Juliet Gopinath, Darren Rand, Aleem M. Siddiqui, Shu-Wei Huang, Enbang Li, Benjamin J. Eggleton, John D. Hybl, Tso Yee Fan, Franz X. Kartner Jan 2010

High-Energy, Picosecond, Cryogenic Yb:Yag Chirped-Pulse Amplifier At Khz Repetition Rates For Opcpa Pumping, Kyung-Han Hong, Juliet Gopinath, Darren Rand, Aleem M. Siddiqui, Shu-Wei Huang, Enbang Li, Benjamin J. Eggleton, John D. Hybl, Tso Yee Fan, Franz X. Kartner

Faculty of Engineering and Information Sciences - Papers: Part A

We report on the development of a 50-mJ-class ~10-ps chirped-pulse amplifier at kHz repetition rates using cryogenic Yb:YAG regenerative and multi-pass amplifiers. The system is well suited as pump laser for kHz high-average-power ultra-broadband OPCPAs. '2010 Optical Society of America


High-Energy, Khz-Repetition-Rate, Ps Cryogenic Yb:Yag Chirped-Pulse Amplifier, Kyung-Han Hong, Juliet Gopinath, Darren Rand, Aleem M. Siddiqui, Shu-Wei Huang, Enbang Li, Benjamin J. Eggleton, John D. Hybl, Tso Yee Fan, Franz X. Kartner Jan 2010

High-Energy, Khz-Repetition-Rate, Ps Cryogenic Yb:Yag Chirped-Pulse Amplifier, Kyung-Han Hong, Juliet Gopinath, Darren Rand, Aleem M. Siddiqui, Shu-Wei Huang, Enbang Li, Benjamin J. Eggleton, John D. Hybl, Tso Yee Fan, Franz X. Kartner

Faculty of Engineering and Information Sciences - Papers: Part A

We demonstrate amplification of picosecond laser pulses to 40 mJ at a 2 kHz pulse repetition frequency (PRF) from a two-stage cryogenic chirped-pulse Yb:YAG amplifier, composed of a regenerative amplifier (RGA) and a two-pass booster amplifier. The RGA produces 8.2 mJ of energy at 2 kHz PRF and 13.2 mJ at 1 kHz PRF with excellent energy stability (~0.3% rms) and beam quality ( M2<1.1 ). Pulse stretching and compression are achieved by using a chirped fiber Bragg grating and a multilayer dielectric grating pair, respectively. Compressed 15 ps pulses from the RGA are obtained with a throughput efficiency of ~80% (~6.5 mJ for 2 kHz ). The booster amplifier further amplifies the pulses to 40 mJ at 2 kHz PRF, and ~32 mJ, ~15 ps pulses are expected after compression. The amplifier chain seeded from a femtosecond Yb-fiber laser enables the optical self-synchronization between signal and pump in optical parametric chirped-pulse amplifier applications.


Investigation Of High Resolution Compact Gamma Camera Module Based On A Continuous Scintillation Crystal Using A Novel Charge Division Readout Method, Qiu-Sheng Dai, Cui-Lan Zhao, Hualin Zhang, Yujin Qi Jan 2010

Investigation Of High Resolution Compact Gamma Camera Module Based On A Continuous Scintillation Crystal Using A Novel Charge Division Readout Method, Qiu-Sheng Dai, Cui-Lan Zhao, Hualin Zhang, Yujin Qi

Faculty of Engineering and Information Sciences - Papers: Part A

The objective of this study is to investigate a high performance and lower cost compact gamma camera module for a multi-head small animal SPECT system. A compact camera module was developed using a thin Lutetium Oxyorthosilicate (LSO) scintillation crystal slice coupled to a Hamamatsu H8500 position sensitive photomultiplier tube (PSPMT). A two-stage charge division readout board based on a novel sub-tractive resistive readout with a truncated center-of-gravity (TCOG) positioning method was developed for the camera. The performance of the camera was evaluated using a flood 99mTc source with a four-quadrant bar-mask phantom. The preliminary experimental results show that the image …


Development Of A Family Of High Strength Low Carbon Microalloyed Ultra-Thin Cast Strip Products Produced By The Castrip® Process, Chris R. Killmore, Kristin R. Carpenter, Harold R. Kaul, James G. Williams, Daniel G. Edelman, Peter C. Campbell, Walter N. Blejde Jan 2010

Development Of A Family Of High Strength Low Carbon Microalloyed Ultra-Thin Cast Strip Products Produced By The Castrip® Process, Chris R. Killmore, Kristin R. Carpenter, Harold R. Kaul, James G. Williams, Daniel G. Edelman, Peter C. Campbell, Walter N. Blejde

Faculty of Engineering and Information Sciences - Papers: Part B

The manufacture of high strength strip products in strip thicknesses less than 1.5mm is very challenging for the conventional hot and cold rolled processing routes. A range of Nb and Nb/V microalloyed steels have been successfully strip cast by the CASTRIP process enabling the development of a range of high strength Ultra-Thin Cast Strip (UCS) products. It was found that the CASTRIP process fully exploits the strengthening potential of the low C-Mn-Nb-(V) alloy design system. Substantial strengthening by microstructural hardening was provided by Nb. Retention of Nb and V in solid solution in hot rolled coils enabled further strengthening by …