Open Access. Powered by Scholars. Published by Universities.®

Environmental Engineering

Flue gas cleaning

Articles 1 - 10 of 10

Full-Text Articles in Environmental Health and Protection

Assessment Of The Impact Of Municipal Waste Incineration Plants On Air Quality And The Possibilities Of Its Reduction, Robert Oleniacz May 2014

Assessment Of The Impact Of Municipal Waste Incineration Plants On Air Quality And The Possibilities Of Its Reduction, Robert Oleniacz

Robert Oleniacz

The planned construction of new municipal waste incineration plants over the next few years in Poland results in protests of local communities, which arise mainly from fear of an increase in the air pollution in its vicinity. These protests extend the investment process and hinder the selection of incineration plant location, but on the other hand they necessitate the use of more efficient solutions to reduce their impact on the air quality.This paper characterizes the world's most widely used technology for municipal solid waste incineration (MSWI) and assesses the possible maximum impact on the air quality of an exemplary MSWI …


Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz Dec 2008

Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz

Robert Oleniacz

The research object was a medical waste incineration plant with a flue-gas treatment system based on dry sorption agent injection to combustion gases before a high-efficiency particulate collector. A combustion system was consisted with the fluidized bed reactor (starved air gasifier) and the secondary combustion chamber. As the dry absorbent was used a mixture of high reactive hydrated lime and activated carbon. Activated carbon content in the mixture was 5-10 % by mass. The absorbent was injected in the minimal recommended amount (4-5 kg/h). Applied collector was a ceramic filter with total filtration area of 120 m2 and guaranteed outlet …


Ocena Skuteczności Działania Suchego Systemu Oczyszczania Spalin Ze Spalania Odpadów Medycznych Opartego Na Wtrysku Sorbentu Wapniowo-Węglowego, Robert Oleniacz Jan 2008

Ocena Skuteczności Działania Suchego Systemu Oczyszczania Spalin Ze Spalania Odpadów Medycznych Opartego Na Wtrysku Sorbentu Wapniowo-Węglowego, Robert Oleniacz

Robert Oleniacz

The research object was a medical waste incineration plant with a capacity of 150 kg per hour equipped with a flue gas treatment system based on dry sorption process using a lime-carbon reagent with adsorbent removing in high-efficiency particulate collector. As the dry sorption agent was used a mixture of high reactive hydrated lime and activated carbon injected to combustion gases by pneumatic feeder. Activated carbon content in the mixture was 5-10 % by mass. Applied collector was ceramic filter with total filtration area of 120 m2 and guaranteed outlet dust concentration under 5 mg/Nm3. Among others things the aims …


Analiza Możliwości Ograniczenia Emisji Zanieczyszczeń Powietrza Z Instalacji Spalania Odpadów Medycznych W Tarnowie, Robert Oleniacz Oct 2006

Analiza Możliwości Ograniczenia Emisji Zanieczyszczeń Powietrza Z Instalacji Spalania Odpadów Medycznych W Tarnowie, Robert Oleniacz

Robert Oleniacz

The paper presents initial research of effects of some factors on the amount of gaseous pollutants formation during medical waste incineration in a two-stage starved air fluidised bed reactor. In the research was included the impact of such factors as oxygen contents in flue gases, frequency of waste loading, momentary mass flow of waste and temperature in the secondary combustion chambers. Measurements showed that the waste incineration in large amount periodically caused excessive emissions incomplete combustion products (CO, HC), especially during wrong operation of the combustion system. The work demonstrated that the essential importance for CO and HC formation reducing …


Metoda Oceny Trudności Oczyszczania I Toksyczności Spalin Powstających Podczas Spalania Odpadów, Robert Oleniacz Nov 2004

Metoda Oceny Trudności Oczyszczania I Toksyczności Spalin Powstających Podczas Spalania Odpadów, Robert Oleniacz

Robert Oleniacz

The paper presents a methodology for evaluating the cleaning difficulty and toxicity of combustion gases from waste incineration based on the knowledge of gases composition. This type of evaluation may be applicable to selection or modernization of flue gas cleaning systems for waste incineration plants and to comparative analy-sis of a pollution degree of raw (unclean) combustion gases. In the evaluation of the cleaning difficulty of gases six categories of difficulty have been identified for removal of selected substances or groups of substances. The evaluation is made individually for substances or groups of substances on condition their concentrations in flue …


Ocena Funkcjonowania Instalacji Oczyszczania Gazów Odlotowych Z Procesu Grafityzacji Elektrod Węglowych W Sgl Carbon S.A. W Nowym Sączu, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Aug 2003

Ocena Funkcjonowania Instalacji Oczyszczania Gazów Odlotowych Z Procesu Grafityzacji Elektrod Węglowych W Sgl Carbon S.A. W Nowym Sączu, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The paper presents a general analysis of the suitability of individual elements of the flue-gas treatment system used in SGL Carbon SA in Nowy Sacz (Poland) for the graphitization process carried out in new LWG furnaces (Castner type). The flue-gas treatment system consisted of two installations: catalytic afterburning and flue-gas desulfurization. The analysis of the suitability of various methods of flue-gas treatment was based primarily on the assessment of the effects of their application, including the reduction of concentrations of selected components in post-graphitizing gases. The work also summarizes the results of evaluation of the functioning of the whole flue-gas …


Termiczne Przekształcanie Odpadów Medycznych W Instalacji Fluidalnej Firmy Seghers – Emisja Zanieczyszczeń Gazowych I Możliwości Jej Ograniczenia, Robert Oleniacz Jan 2003

Termiczne Przekształcanie Odpadów Medycznych W Instalacji Fluidalnej Firmy Seghers – Emisja Zanieczyszczeń Gazowych I Możliwości Jej Ograniczenia, Robert Oleniacz

Robert Oleniacz

The paper presents the results of measurements of concentrations and mass streams of selected components in the flue gases from the thermal treatment of medical waste in the Seghers incinerator based on fluidized bed reactor.

The tests were carried out at the measuring points located both before and after of the flue-gas cleaning system based on the injection of dry hydrated lime and carbon sorbent and a ceramic filter. In this way it was possible to determine the effectiveness of the removal of selected air pollutants in the dry cleaning system. Analysis of the results of measurements made ​​it possible …


Ocena Składu Gazów Odlotowych Z Procesów Spopielania Odpadów Niebezpiecznych Pod Kątem Trudności Oczyszczania I Toksyczności, Robert Oleniacz Dec 2001

Ocena Składu Gazów Odlotowych Z Procesów Spopielania Odpadów Niebezpiecznych Pod Kątem Trudności Oczyszczania I Toksyczności, Robert Oleniacz

Robert Oleniacz

Tightening of the European Union law in the field of the air emission limit values from waste incineration causes necessity for existing and new incineration plants to conform to the standards. It will often involve modernization of the flue gas cleaning system. Proposed in the paper the methodology of evaluation of the combustion gases composition in point of view cleaning difficulty should be useful to this end. Average toxicity factors for hazardous waste incineration flue gases were defined as well. Among other things they can be used in comparative analysis of the air pollutant concentration in the raw gas (before …


Dobór Systemu Oczyszczania Gazów Odlotowych Ze Spalania Odpadów Niebezpiecznych, Robert Oleniacz Jun 2001

Dobór Systemu Oczyszczania Gazów Odlotowych Ze Spalania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The flue gas cleaning system is usually one of the most costly elements of the installation to the incineration of hazardous waste. Adapting the system to the actual needs could therefore bring obvious economic benefits.

The paper presents the method of the preselection of the configuration of the cleaning system based on knowledge of the level of concentration of selected components of the raw exhaust gas (sulfur dioxide, hydrogen chloride, hydrogen fluoride, total dust, mercury, cadmium and thallium, and other heavy metals). Twelve examples of flue-gas cleaning systems were proposed and extreme concentration values of the substances in the raw …


Termiczna Utylizacja Odpadów W Spalarni "Lobbe" W Dąbrowie Górniczej – Problemy Emisji Zanieczyszczeń, Marian Mazur, Ryszard Januszek, Robert Oleniacz May 1996

Termiczna Utylizacja Odpadów W Spalarni "Lobbe" W Dąbrowie Górniczej – Problemy Emisji Zanieczyszczeń, Marian Mazur, Ryszard Januszek, Robert Oleniacz

Robert Oleniacz

The paper presents selected results of comprehensive studies of air quality impact assessment carried out for the „LOBBE” incineration plant in Dąbrowa Górnicza (Poland) in 1995. It focused mainly on air emissions problems. Stack concentrations and emissions of selected air pollutants formed during thermal treatment processes of different kinds of waste materials and incinerators is performed. The study covered both sludge and slime incinerated in a multiple hearth furnace and four example groups of waste materials incinerated in a rotary furnace. The research have helped confirm the levels of air emissions as a function of the type of incinerated waste …