Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

2001

Civil and Environmental Engineering

Institution
Keyword
Publication
Publication Type

Articles 1 - 20 of 20

Full-Text Articles in Physical Sciences and Mathematics

Ocena Składu Gazów Odlotowych Z Procesów Spopielania Odpadów Niebezpiecznych Pod Kątem Trudności Oczyszczania I Toksyczności, Robert Oleniacz Dec 2001

Ocena Składu Gazów Odlotowych Z Procesów Spopielania Odpadów Niebezpiecznych Pod Kątem Trudności Oczyszczania I Toksyczności, Robert Oleniacz

Robert Oleniacz

Tightening of the European Union law in the field of the air emission limit values from waste incineration causes necessity for existing and new incineration plants to conform to the standards. It will often involve modernization of the flue gas cleaning system. Proposed in the paper the methodology of evaluation of the combustion gases composition in point of view cleaning difficulty should be useful to this end. Average toxicity factors for hazardous waste incineration flue gases were defined as well. Among other things they can be used in comparative analysis of the air pollutant concentration in the raw gas (before …


Lower Willamette River Model: Model Calibration, Chris Berger, Robert Leslie Annear, Scott A. Wells Dec 2001

Lower Willamette River Model: Model Calibration, Chris Berger, Robert Leslie Annear, Scott A. Wells

Civil and Environmental Engineering Faculty Publications and Presentations

Water Environment Services of Clackamas County is in the process of planning upgrades on several of its wastewater treatment plants (WWTPs) which discharge into the Lower Willamette River. The goals of the modeling effort were to:

• Gather data to construct a computer simulation model of the Lower Willamette River system in order to evaluate the impact of the WWTP discharges on water quality

• Ensure that the model accurately represents the system physics and chemistry (flow, temperature, dissolved oxygen and nutrient dynamics) by model calibration

• Use the model to evaluate how to meet various future discharge scenarios for …


Three Dimensional Hydrodynamic Modeling Study, Craney Island Eastward Expansion, Lower James River And Elizabeth River, Virginia, Harry V. Wang, S. C. Kim, John D. Boon, A. Y. Kuo, G. M. Sisson, J. M. Brubaker, J. P-Y. Maa Dec 2001

Three Dimensional Hydrodynamic Modeling Study, Craney Island Eastward Expansion, Lower James River And Elizabeth River, Virginia, Harry V. Wang, S. C. Kim, John D. Boon, A. Y. Kuo, G. M. Sisson, J. M. Brubaker, J. P-Y. Maa

Reports

The Craney Island Eastward Expansion Hydrodynamic Model Study was conducted in three phases: 1) model calibration and verification for the Elizabeth River, 2) model testing of four Craney Island expansion options using single variable runs (using a single variable, tidal range, for model input), 3) model testing of two expansion options using historical runs (using multiple variables in real time for model input). The expansion option designs were evaluated for both global and local hydrodynamic change through simulation comparisons with the Base Case condition.


Lower Willamette River Model: Boundary Conditions And Model Setup, Herman G. Rodriguez, Robert Leslie Annear, Scott A. Wells, Chris Berger Nov 2001

Lower Willamette River Model: Boundary Conditions And Model Setup, Herman G. Rodriguez, Robert Leslie Annear, Scott A. Wells, Chris Berger

Civil and Environmental Engineering Faculty Publications and Presentations

Water Environment Services of Clackamas County is in the process of planning upgrades on several of its sewage treatment plants which discharge into the Lower Willamette River. The goals of the modeling effort are to:

• Gather data to construct a computer simulation model of the Lower Willamette River system including part of the Lower Columbia River and the Willamette River above the Oregon City Falls; Because of the tidal influence in the Lower Willamette River, portions of the Columbia River that might affect the Lower Willamette River water quality were also modeled. Also, a section of the Willamette River …


Upper Spokane River Model: Boundary Conditions And Model Setup, 1991 And 2000, Robert Leslie Annear, Chris Berger, Scott A. Wells Nov 2001

Upper Spokane River Model: Boundary Conditions And Model Setup, 1991 And 2000, Robert Leslie Annear, Chris Berger, Scott A. Wells

Civil and Environmental Engineering Faculty Publications and Presentations

The Washington Department of Ecology is interested in a water quality model for the Upper Spokane River system for use in developing Total Maximum Daily Loads (TMDLs). The goals of this modeling effort are to:

• Gather data to construct a computer simulation model of the Spokane River system including Long Lake Reservoir and the pools behind Nine Mile dam, Upper Falls dam and Upriver dam

• Ensure that the model accurately represents the system hydrodynamics and water quality (flow, temperature, dissolved oxygen and nutrient dynamics)

A hydrodynamic and water quality model, CE-QUAL-W2 Version 3 (Wells, 1997), is being applied …


Czynniki Wpływające Na Skład Spalin I Wielkość Emisji Zanieczyszczeń Z Procesów Termicznego Przekształcania Odpadów Niebezpiecznych, Robert Oleniacz Oct 2001

Czynniki Wpływające Na Skład Spalin I Wielkość Emisji Zanieczyszczeń Z Procesów Termicznego Przekształcania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The work summarizes factors influencing on air emissions from various full-scale hazardous waste incinerators (rotary kiln, multiple hearth furnace, starved-air incinerator, fluidized bed incinerator, liquid injection incinerator). Air pollutant emissions from hazardous waste incineration can be minimized not only by flue-gas cleaning. There are many factors that influence on flue-gas composition and the quantity of air pollutants formed during incineration: the type, the composition and the quantity of waste, the way of waste introducing to the incinerator, excess air ratio, combustion temperature, retention time of exhaust gases etc. Special attention was paid to the loading of waste and incineration conditions …


Odpady Pestycydowe Jako Paliwo Zastępcze W Piecach Obrotowych Do Wypalania Klinkieru Cementowego, Marian Mazur, Robert Oleniacz, Marek Bogacki, Stanisław Słupek Oct 2001

Odpady Pestycydowe Jako Paliwo Zastępcze W Piecach Obrotowych Do Wypalania Klinkieru Cementowego, Marian Mazur, Robert Oleniacz, Marek Bogacki, Stanisław Słupek

Robert Oleniacz

The clinker burning plant is ideally suited for processing a wide variety of hazardous waste materials. High temperatures existing in cement kilns (ca. 1350-1450 Centigrades in the burning zone) as well as long gas-residence time (ca. 6-10 s) provide potentially excellent conditions for destruction of toxic organic compounds. Non-volatile compounds are retained in the solid phase and built into the clinker. A lot of other (for example acid gases) can also be absorbed by alkaline solid phase. Old pesticide wastes present a big problem in Poland now. They can be use as waste-derived fuels in cement kilns, especially in the …


Ocena Udziału Huty Katowice W Poziomie Opadu Pyłu, Ołowiu I Kadmu Na Powierzchnię Terenu Wokół Zakładu, Marian Mazur, Robert Oleniacz, Marek Bogacki Sep 2001

Ocena Udziału Huty Katowice W Poziomie Opadu Pyłu, Ołowiu I Kadmu Na Powierzchnię Terenu Wokół Zakładu, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of modeling of deposition on the land surface of dust, lead and cadmium emitted from the "Katowice" Steelworks. The calculations were carried out in the vicinity of the location of the dust deposition measuring points existing around the plant. Computational data were compared with the results obtained from direct measurements for the same calendar year. The responsibility of this plant in shaping the level of dust and heavy metal deposition in the region of the protective zone was determined.

English title: Participation of the "Katowice" Steelworks in the level of dust, lead and cadmium deposition …


Prognoza Wpływu Na Stan Zanieczyszczenia Powietrza Procesu Unieszkodliwiania Odpadów Pestycydowych W Piecu Cementowym, Marian Mazur, Robert Oleniacz, Marek Bogacki Sep 2001

Prognoza Wpływu Na Stan Zanieczyszczenia Powietrza Procesu Unieszkodliwiania Odpadów Pestycydowych W Piecu Cementowym, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the general conditions associated with running of pesticide waste co-incineration in rotary kilns for cement clinker burning, and describes the behavior of toxic substances entering to this process with waste materials or forming as the result of thermal decomposition. Additional air emissions and their impact on air quality were also assessed.

English title: Prediction of the impact on the state of air pollution for the process of pesticide waste disposal in a cement kiln.


The Dissolution Of Dnapls In Variable Aperture Fractures, Sarah E. Dickson Sep 2001

The Dissolution Of Dnapls In Variable Aperture Fractures, Sarah E. Dickson

Sarah E Dickson

No abstract provided.


Średni Współczynnik Toksyczności Spalin Emitowanych Z Procesów Spopielania Odpadów Niebezpiecznych, Robert Oleniacz Aug 2001

Średni Współczynnik Toksyczności Spalin Emitowanych Z Procesów Spopielania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The paper presents the characteristics of the Average Toxicity Factor (ATF) for combustion gases emitted from incineration of hazardous waste. Proposals for the interpretation of this factor and the possibility of its use in assessing the degree of nuisance of the process in terms of the level of air pollutant emissions were also discussed.

English title: Average toxicity factor of combustion gases emitted from hazardous waste incineration.


Ascent And Decompression Of Viscous Vesicular Magma In A Volcanic Conduit, Helene Massol, Claude Jaupart, Darrell Pepper Aug 2001

Ascent And Decompression Of Viscous Vesicular Magma In A Volcanic Conduit, Helene Massol, Claude Jaupart, Darrell Pepper

Mechanical Engineering Faculty Research

During eruption, lava domes and flows may become unstable and generate dangerous explosions. Fossil lava-filled eruption conduits and ancient lava flows are often characterized by complex internal variations of gas content. These observations indicate a need for accurate predictions of the distribution of gas content and bubble pressure in an eruption conduit. Bubbly magma behaves as a compressible viscous liquid involving three different pressures: those of the gas and magma phases, and that of the exterior. To solve for these three different pressures, one must account for expansion in all directions and hence for both horizontal and vertical velocity components. …


Dobór Systemu Oczyszczania Gazów Odlotowych Ze Spalania Odpadów Niebezpiecznych, Robert Oleniacz Jun 2001

Dobór Systemu Oczyszczania Gazów Odlotowych Ze Spalania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The flue gas cleaning system is usually one of the most costly elements of the installation to the incineration of hazardous waste. Adapting the system to the actual needs could therefore bring obvious economic benefits.

The paper presents the method of the preselection of the configuration of the cleaning system based on knowledge of the level of concentration of selected components of the raw exhaust gas (sulfur dioxide, hydrogen chloride, hydrogen fluoride, total dust, mercury, cadmium and thallium, and other heavy metals). Twelve examples of flue-gas cleaning systems were proposed and extreme concentration values of the substances in the raw …


Niezorganizowana Emisja Zanieczyszczeń Powietrza Z Hal Ciągłego Odlewania Stali, Marian Mazur, Marek Bogacki, Robert Oleniacz, Agnieszka Łopata Jun 2001

Niezorganizowana Emisja Zanieczyszczeń Powietrza Z Hal Ciągłego Odlewania Stali, Marian Mazur, Marek Bogacki, Robert Oleniacz, Agnieszka Łopata

Robert Oleniacz

Air pollutant emissions occurring in an uncontrolled way do not be subject to the regular verification just like it takes place in case of the controlled sources, for which the routine measurements are carried out. In the paper a methodology and the results of some research were presented. The research consisted in determination the quantity of dust and gaseous pollutants emitted from the halls in which technological processes connected with the steel continuous casting were being run. Stocktaking of all the uncontrolled emission sources were carried out and the technological operations predominating in the level of the particle matter and …


Statistical Properties Of Maximum Likelihood Estimates For Accelerated Lifetime Data Under The Weibull Model, Mahmoud A. Yousef Apr 2001

Statistical Properties Of Maximum Likelihood Estimates For Accelerated Lifetime Data Under The Weibull Model, Mahmoud A. Yousef

Doctoral Dissertations

Pipe rehabilitation liners are often installed in host pipes that lie below the water table. As such, they are subjected to external hydrostatic pressure. The external pressure leads to early deformation in the liners, which could ultimately lead to its failing or buckling before its expected service lifetime is achieved. Experiments involving long term buckling behavior of liners are typically accelerated lifetime testing procedures. In an accelerated testing procedure a liner is subjected to a constant external hydrostatic pressure and observed until it fails or for a certain time, t whichever occurs first. Liners that do not fail at time …


Quantitative Validation Of A Model Of Chlorinated Ethene Natural Attenuation, Harold C. Young Mar 2001

Quantitative Validation Of A Model Of Chlorinated Ethene Natural Attenuation, Harold C. Young

Theses and Dissertations

Chlorinated ethenes are among the most prevalent groundwater contaminants at hazardous waste sites nationwide. In an attempt to manage the risks posed by these contaminants, while controlling costs, monitored natural attenuation (MNA) is being considered as a remediation strategy at many sites. MNA relies on naturally occurring physical, chemical, and biological processes in the subsurface to reduce the risk posed by the contamination. The implementation of MNA, however, requires a detailed understanding of these processes, and how they impact contamination at a particular site. One way to gain this understanding is through contaminant fate and transport modeling. In this study, …


A Model For Palladium Catalyzed Destruction Of Chlorinated Ethenes In Contaminated Groundwater, Christopher M. Stoppel Mar 2001

A Model For Palladium Catalyzed Destruction Of Chlorinated Ethenes In Contaminated Groundwater, Christopher M. Stoppel

Theses and Dissertations

Groundwater contamination by chlorinated ethenes is a widespread environmental problem. Conventional remediation technologies have shortcomings that have prompted further research into the development of novel treatment technologies. A palladium/ alumina catalyst in the presence of dissolved molecular hydrogen (referred to hereafter as a PD/H2 system) has been demonstrated to rapidly destroy chlorinated ethene contaminated groundwater. First-order kinetics have been used to model chlorinated ethene destruction in a PD/H2 reactor. However, catalyst deactivation and regeneration are important processes that also need to be modeled in order to better understand their effect on treatment efficiency. This study presents a model …


Determining The Value Of Groundwater Contamination Source Removal: A Methodology, Benjamin C. Recker Mar 2001

Determining The Value Of Groundwater Contamination Source Removal: A Methodology, Benjamin C. Recker

Theses and Dissertations

Subsurface contamination by industrial chemicals is one of the most prevalent and costly environmental problems facing the United States government. This contamination problem must be managed to protect human health and the environment. Two basic strategies are used to deal with subsurface contamination: source removal and contaminant containment. While much cost and performance data are available for individual technologies associated with each of these strategies, there have been very few studies that have examined the benefits of implementing source removal technologies in order to reduce contaminant containment (and hopefully total) costs. This study examines the tradeoff between extent of source …


Development Of A Low-Cost, Self-Calibrating Stream Gaging Station, Gilberto Urroz, Robert C. Leines, Garryn L. Perret, Jared M. Holland, Brian E. Hunsaker Jan 2001

Development Of A Low-Cost, Self-Calibrating Stream Gaging Station, Gilberto Urroz, Robert C. Leines, Garryn L. Perret, Jared M. Holland, Brian E. Hunsaker

Reports

Executive Summary: The present report presents a review of the state-of-the-art technologies for the development of a low-cost, self-calibrating stream gaging station. The research was conducted by the Utah Water Research Laboratory with funding provided by the Utah Division of Water Resources through Project RP 110080, March 1998. The report presents a review of the current practices in stream gaging and how technologies such as remote data telemetry through the use of satellite, cellular phone communications, and radio telemetry can be used for the real-time transmission of data. The study also includes the use of Global Positioning System (GPS) for …


Concrete Roughness Characterization Using Laser Profilometry For Fiber-Reinforced Polymer Sheet Application, Norbert H. Maerz, Poornima Chepur, John J. Myers, Justin Linz Jan 2001

Concrete Roughness Characterization Using Laser Profilometry For Fiber-Reinforced Polymer Sheet Application, Norbert H. Maerz, Poornima Chepur, John J. Myers, Justin Linz

Geosciences and Geological and Petroleum Engineering Faculty Research & Creative Works

The failure of a reinforced concrete member strengthened with fiberreinforced polymer (FRP) laminates may be caused by crushing of concrete, rupture of FRP laminates, or delamination of the FRP sheet. Therefore, the effectiveness and failure mode of FRP sheets applied to beams and columns is related to the degree of adhesion of the epoxy to the concrete surface. When a peeling or delamination failure can be avoided, a more effective engagement of the FRP sheet occurs, which results in more efficient use of the material. One of the principal factors affecting the bond behavior between the concrete and epoxy is …