Emisja Zanieczyszczeń Ze Spalania Odpadów Ściekowych W Piecu Półkowym, Robert Oleniacz, Marian Mazur, Marek Bogacki
Emisja Zanieczyszczeń Ze Spalania Odpadów Ściekowych W Piecu Półkowym, Robert Oleniacz, Marian Mazur, Marek Bogacki
Robert Oleniacz
The article presents incineration tests of silty-tar sludge produced in the wastewater treatment plant for coke industry. Sewage sludges were incinerated in a full-scale multiple hearth incinerator equipped with a wet flue-gas cleaning system (alkaline scrubber). Measurements of air pollutant emissions were carried out both before and after the cleaning system. The obtained results allow to conclude that the thermal utilization of sewage sludge in this type of installation might be just a little cumbersome for the environment, using the appropriate equipment for the purification of exhaust gases. The paper also specifies minimum exhaust gas cleaning performance that guarantees compliance …
Emisja Zanieczyszczeń Ze Spalania Odpadów Farmaceutycznych I Poszpitalnych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki
Emisja Zanieczyszczeń Ze Spalania Odpadów Farmaceutycznych I Poszpitalnych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki
Robert Oleniacz
The work presents the problem of management and thermal treatment of medicines and hospital wastes and investigation results of incineration of these waste in the full-scale rotary kiln with wet gas cleaning equipment (alkaline scrubber). On the basis of measurements of air pollutant concentrations in combustion gases, maximum dose of these wastes in the feed to the kiln was specified in order to ensure a relatively low stack emissions using the hypothetical high-efficiency flue-gas treatment system.
English title: Pollutant emissions from incineration of pharmaceutical and hospital waste in a rotary kiln.
Emisja Zanieczyszczeń Ze Spalania Odpadów Przemysłowych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki
Emisja Zanieczyszczeń Ze Spalania Odpadów Przemysłowych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki
Robert Oleniacz
The paper presents the results of measurements of the concentration of selected pollutants in the flue gases from the incineration of industrial wastes in a full-scale rotary kiln. The study included three waste mixtures introduced into the kiln: 1) coal tar waste (tar origin of coke); 1) waste paints, varnish and lubricant; 3) resin and rubber waste. The article also assesses the effectiveness of the existing wet flue gas cleaning system (alkaline scrubber) and specifies minimum exhaust gas purifying performance guarantees compliance with European emission standards for waste incineration.
English title: Pollutant emissions from incineration of industrial waste in a …
Monitoring Zanieczyszczeń Powietrza Wokół Elektrowni "Jaworzno Iii", Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz
Monitoring Zanieczyszczeń Powietrza Wokół Elektrowni "Jaworzno Iii", Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz
Robert Oleniacz
The article presents the concept of system of monitoring of air pollution around the Power Plant "Jaworzno III" in Jaworzno (Poland), whose objective is to evaluate the impact of this object on air quality. This system is based on a few measuring points and a mobile station should also allow for the assessment of ecological effects associated with the use of low-emission burners in power boilers (reduction of NOx emission) and run the wet installation of flue gas desulfurization (reduction of SO2 emission). An additional aim of the measurements is to identify the possible effects of a changes in the …
Termiczna Utylizacja Odpadów W Spalarni "Lobbe" W Dąbrowie Górniczej – Problemy Emisji Zanieczyszczeń, Marian Mazur, Ryszard Januszek, Robert Oleniacz
Termiczna Utylizacja Odpadów W Spalarni "Lobbe" W Dąbrowie Górniczej – Problemy Emisji Zanieczyszczeń, Marian Mazur, Ryszard Januszek, Robert Oleniacz
Robert Oleniacz
The paper presents selected results of comprehensive studies of air quality impact assessment carried out for the „LOBBE” incineration plant in Dąbrowa Górnicza (Poland) in 1995. It focused mainly on air emissions problems. Stack concentrations and emissions of selected air pollutants formed during thermal treatment processes of different kinds of waste materials and incinerators is performed. The study covered both sludge and slime incinerated in a multiple hearth furnace and four example groups of waste materials incinerated in a rotary furnace. The research have helped confirm the levels of air emissions as a function of the type of incinerated waste …
Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz
Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz
Robert Oleniacz
The article evaluates the impact of electrode industry (production of carbon and graphite electrodes in the plant Polgraph SA) on air quality in the Kotlina Sądecka valley and the city Nowy Sącz (Poland). The work presents completed so far environmental investments and the level of emissions of selected air pollutants characteristic of the analyzed facility, including PAHs emissions. Based on the modeling of the dispersion of pollutants in ambient air was determined the levels of pollutant concentrations in the air and location of most affected areas. The calculation results were compared with the results of direct measurements. Particular attention was …